Field Wire Conversion Module for Modicon B805-016 or B853-016 to 1756-IA16
(Cat 1492-CM800-LD003)
10000021858 (Version 00)
Printed in Germany
Local language (French, Italian, German & Spanish) versions of this document can be downloaded by going to www.ab.com.
In the left margin click on Publications Library and Literature Library. In the Search Area (right margin), Search by Catalog
Number and in the Search box type in the catalog number of the conversion system component.
I. Module Description
The 1492-CM800-LD003 conversion module provides field wire signal conversion from a Modicon® B805-016 or
B853-016, 80 to 130Vac , 16-pt input module to a ControLogix 1756-IA16, 74 to 132Vac , 16-pt input module. The
conversion module provides the mating connections to the B805-016 or B853-016 swing-arm (terminal block) with the
attached field wires. It routes those signals via its 20-pin connector and a 1492-CABLEX pre-wired cable to compat-
ible terminals of the 1756-IA16 (refer to the Wiring Diagram on pages 2 and 3).
II. Module Installation
The 1492-CM800-LD003 conversion module must be installed in a 1492 conversion base-plate and cover-plate
assembly. The installation of the module into the assembly is explained in the Installation Manual that ships with the
conversion assembly. For a list of compatible assemblies refer to Appendix A.
III. Conversion Module Compatibility Matrix
This is the cable length in meters and tenths of meters (e.g. 015 = 1.5 meters). Recommended cable
length is 003 (00.3 meters).
Conversion Module Compatible 800
Input Module
Compatible 1756
Input Module
Required 1492 Cable
1492-CM800-LD003 B805-016 1756-IA16 1492-CABLE
X
1492-CM800-LD003 B853-016 1756-IA16 1492-CABLE
X
20-pin connector for 1492-CABLE
X
Mating connector for
B800 Terminal Block
1492-CM800-LD003 Conversion Module
De-energize and lockout any and all power to all I/O field devices connected to the Modicon 800 I/O
housing, and the power to the 800 I/O housing itself. Ensure all power is de-energized and locked out
to any device in the control cabinet where the conversion is to be performed. Ensure work is
performed by qualified personnel.
WARNING
Refer to conversion module Specifications Section: Maximum Operating Voltage
10
L2-0
IN-0
1
IN-1
2
IN-2
3
IN-3
4
IN-4
5
IN-5
6
IN-6
7
IN-7
8
IN-8
11
IN-9
12
IN-10
13
IN-11
14
IN-12
15
IN-13
16
IN-14
17
IN-15
18
Black
White
Red
Green
Orange
Blue
White/Black
Red/Black
Green/Black
Orange/Black
Blue/Black
Black/White
Red/White
Green/White
Blue/White
Black/Red
White/Red
Orange/Red
Blue/Red
Red/Green
L2-1
20
9
L2-0
19
L2-1
9 1
1
19
2
3
3
4
4
5
5
6
6
7
7
8
8
9
19
10
1111
12
12
13
13
14
15
15
16
16
17
17
18 18
20
14
2
L1
L2
Input 13
Input 15
Input 14
Input 16
Input 5
Input 7
Input 6
Input 8
Input 1
Input 3
Input 2
Input 4
Input 9
Input 11
Input 10
Input 12
Neutral Grp 1
Neutral Grp 2
10
20
Not Used
Not Used
Komentarze do niniejszej Instrukcji