Publication 1394-5.0 — May 2000
Configuring Your 1394 Analog Servo System 8-23
[Sys Mod Data]
Diagnostic information of data communicated
between the controller and system module.
Parameter Numbers 6
Parameter Group Linear List
Parameter Type Read Only
[Sys Mod Status 2]
Diagnostic information of smart power systems.
Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems
1 = true
Note: Warnings are set at 80% rating.
Parameter Numbers 38
Parameter Group Linear List
Parameter Type Read Only
[System Type]
Catalog number of System Module. Set during
the initialization of the 1394
x
-SJT
xx
-A system
module.
Parameter Numbers 14
Parameter Group Configuration
Display Units None
Parameter Type Read Only
Linkable No
0 "NOT PRESENT"
1 "1394
x
-SJT05"
2 "1394
x
-SJT10"
3 "1394-SJT22"
[Test Mode Sel]
Internal (factory) test mode selections.
Parameter Numbers 16
Parameter Group Linear List
Display Units None
Parameter Type Read/Write
Change While Running Ye s
Linkable No
Minimum Value 0
Maximum Value 32767
Default Value 0
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Version Bits
Ctrl Pwr Loss
Ovr Temp Flt
Bus Undr Vlt
Bus 0V Flt
Phs Loss Flt
Ground Fault
Size Bit
Not Used
Size Bit
Size Bit
Size Bit
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
CurLim Fault
Shunt Warn
Ctrl Pwr Loss
Ovr Temp Flt
Bus Undr Vlt
Bus 0V Fault
Phs Loss Flt
Ground Fault
Shunt Fault
CurLim Warn
Not Used
PreCharge Fault
Komentarze do niniejszej Instrukcji