SMC Dialog Plus Smart Motor Controller
3-27
Preset Slow Speed Option
The Preset Slow Speed option can be used on applications that require
a slow speed for positioning material. The Preset Slow Speed can be
set for either Low, 7% of base speed, or High, 15% of base speed.
Reversing is also possible through programming. Speeds provided
during reverse operation are Low, 10% of base speed, or High, 20%
of base speed.
Figure 3.22 Preset Slow Speed Option
!
ATTENTION: Slow speed running is not intended fo
continuous operation due to reduced motor cooling.