Installation Instructions
1732E ArmorBlock Dual-Port
EtherNet/IP 4-Point Analog Input and
Output Modules
Catalog Numbers 1732E-IF4M12R, 1732E-OF4M12R
Table of Contents
Topic Page
Important User Information 2
Environment and Enclosure 3
Preventing Electrostatic Discharge 3
Overview 4
Catalog Number Explanation 6
Install the Module 6
Set the Network Address 6
Mount the Module 8
Product Dimensions 8
Connect the I/O, Network and Auxiliary Cables to the Module 10
Configure the Module 14
Interpret LED Indicators 16
Specifications 19
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - Output Modules

Installation Instructions1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output ModulesCatalog Numbers 1732E-IF4M12R, 1732E-OF4M12RTab

Strona 2 - Important User Information

10 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013Mount the Module in High

Strona 3 - Environment and Enclosure

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 11Publication 1732E-IN006C-EN-E - June 2013Micro-style M12 5-Pin In

Strona 4 - Overview

12 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013Voltage Mode Connections

Strona 5 - Module Identification

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 13Publication 1732E-IN006C-EN-E - June 2013Current Mode Connections

Strona 6 - Install the Module

14 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013Configure the ModuleRefe

Strona 7 - Set Network Address

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 15Publication 1732E-IN006C-EN-E - June 2013Power ConnectorsAttach t

Strona 8 - Mount the Module

16 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013Interpret LED Indicators

Strona 9 - Module Dimensions

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 17Publication 1732E-IN006C-EN-E - June 2013Status Indicators Li

Strona 10 - I/O Connectors

18 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013Indicator Status for Mod

Strona 11 - Ethernet Connector

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 19Publication 1732E-IN006C-EN-E - June 2013Specifications I

Strona 12 - 4-wire connection

2 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013Important User Informatio

Strona 13 - 2-wire connection

20 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013Dimensions, approx., HxW

Strona 14 - Configure the Module

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 21Publication 1732E-IN006C-EN-E - June 2013Output Specifications –

Strona 15 - Power Connectors

22 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013 Shock, nonoperating IEC

Strona 16 - Interpret LED Indicators

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 23Publication 1732E-IN006C-EN-E - June 2013C-Tick Australian Radioc

Strona 17 - Status Indicators

Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellau

Strona 18 - Indicator Status for Modules

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 3Publication 1732E-IN006C-EN-E - June 2013Environment and Enclosure

Strona 19 -

4 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013Additional ResourcesIf yo

Strona 20 - General Specifications

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 5Publication 1732E-IN006C-EN-E - June 2013Module Identification (1

Strona 21 - Environmental Specifications

6 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013Optional AccessoryThe fol

Strona 22 - Certifications

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 7Publication 1732E-IN006C-EN-E - June 2013• retrieve the IP address

Strona 23

8 1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules Publication 1732E-IN006C-EN-E - June 2013Network Address Switch va

Strona 24 - Documentation Feedback

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Analog Input and Output Modules 9Publication 1732E-IN006C-EN-E - June 2013Module Dimensions37 (1.46