Rockwell-automation 1734-IE4C POINT I/O 4 Channel High Density Current Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation 1734-IE4C POINT I/O 4 Channel High Density Current. Rockwell Automation 1734-IE4C POINT I/O 4 Channel High Density Current Input Module Installat User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 24
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Installation Instructions
POINT I/O 4 Channel High Density Current
Input Module
Catalog Number 1734-IE4C
Topic Page
Important User Information 2
Environment and Enclosure 3
Prevent Electrostatic Discharge 4
European Hazardous Location Approval 5
North American Hazardous Location Approval 6
Before You Begin 7
Install the Mounting Base 8
Install the I/O Module 9
Install the Removable Terminal Block (RTB) 11
Remove a Mounting Base 11
Communicating with Your Module 12
Wiring the Input Analog Module 14
Wiring Diagram 14
Interpret the Indicators 15
Specifications 17
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - Input Module

Installation InstructionsPOINT I/O 4 Channel High Density Current Input ModuleCatalog Number 1734-IE4C Topic PageImportant User Information 2Environm

Strona 2 - Important User Information

10 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 20121734-TOP Base1. Using a bladed screwdriver, rotate

Strona 3 - Environment and Enclosure

POINT I/O 4 Channel High Density Current Input Module 11Publication 1734-IN032C-EN-P - June 2012Install the Removable Terminal Block (RTB)A remova

Strona 4

12 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 2012Install a 1734-TOPS Base1. Position the base verti

Strona 5

POINT I/O 4 Channel High Density Current Input Module 13Publication 1734-IN032C-EN-P - June 2012Default Data Map for the 1734-IE4C Analog Input Mo

Strona 6

14 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 2012Wiring the Input Analog Module Wiring Diagram C

Strona 7 - Before You Begin

POINT I/O 4 Channel High Density Current Input Module 15Publication 1734-IN032C-EN-P - June 2012Interpret the Indicators Indicator State Descript

Strona 8 - Install the Mounting Base

16 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 2012Network statusOff Device is not on-line- Device ha

Strona 9 - Install the I/O Module

POINT I/O 4 Channel High Density Current Input Module 17Publication 1734-IN032C-EN-P - June 2012Specifications IMPORTANTNote that the Input

Strona 10 - 1734-TOP Base

18 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 2012Input impedance/resistance conversion type60 ΩSigm

Strona 11 - Remove a Mounting Base

POINT I/O 4 Channel High Density Current Input Module 19Publication 1734-IN032C-EN-P - June 2012General SpecificationsAttribute ValueModule locati

Strona 12 - Remove a 1734-TOPS Base

2 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 2012Important User Information Solid state equipment h

Strona 13 - Publication

20 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 2012Environmental SpecificationsAttribute ValueTempera

Strona 14 - Wiring Diagram

POINT I/O 4 Channel High Density Current Input Module 21Publication 1734-IN032C-EN-P - June 2012Surge transient immunityIEC 61000-4-5:±1 kV line-l

Strona 15 - Interpret the Indicators

22 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 2012Additional ResourcesThese documents contain additi

Strona 16

POINT I/O 4 Channel High Density Current Input Module 23Publication 1734-IN032C-EN-P - June 2012Notes:

Strona 17 - Specifications

Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellau

Strona 18 - Input Specifications

POINT I/O 4 Channel High Density Current Input Module 3Publication 1734-IN032C-EN-P - June 2012Environment and Enclosure ATTENTIONThis equipment

Strona 19 - General Specifications

4 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 2012Prevent Electrostatic Discharge ATTENTIONThis

Strona 20 - Environmental Specifications

POINT I/O 4 Channel High Density Current Input Module 5Publication 1734-IN032C-EN-P - June 2012European Hazardous Location Approval European Zone

Strona 21 - Certifications

6 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 2012North American Hazardous Location Approval The fol

Strona 22 - Additional Resources

POINT I/O 4 Channel High Density Current Input Module 7Publication 1734-IN032C-EN-P - June 2012Before You BeginNote that this series C product can

Strona 23

8 POINT I/O 4 Channel High Density Current Input Module Publication 1734-IN032C-EN-P - June 2012Install the Mounting BaseTo install the mounting ba

Strona 24 - Installation Assistance

POINT I/O 4 Channel High Density Current Input Module 9Publication 1734-IN032C-EN-P - June 2012Install the I/O ModuleThe module can be installed b

Komentarze do niniejszej Instrukcji

Brak uwag