Installation Instructions
POINT I/O 8 Channel High Density Current
Input Module
Catalog Number 1734-IE8C
Topic Page
Important User Information 2
Environment and Enclosure 3
Prevent Electrostatic Discharge 4
European Hazardous Location Approval 5
North American Hazardous Location Approval 6
Before You Begin 7
Install the Mounting Base 8
Install the I/O Module 9
Install the Removable Terminal Block (RTB) 11
Remove a Mounting Base 11
Communicating with Your Module 12
Wiring the Input Analog Module 14
Wiring Diagram 14
Interpret the Indicators 15
Specifications 17
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - Input Module

Installation InstructionsPOINT I/O 8 Channel High Density Current Input ModuleCatalog Number 1734-IE8C Topic PageImportant User Information 2Environm

Strona 2 - Important User Information

10 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 20101734-TOP Base1. Using a bladed screwdriver, r

Strona 3 - Environment and Enclosure

POINT I/O 8 Channel High Density Current Input Modules 11Publication 1734-IN033B-EN-P - November 2010Install the Removable Terminal Block (RTB)A r

Strona 4

12 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Install a 1734-TOPS Base1. Position the base

Strona 5

POINT I/O 8 Channel High Density Current Input Modules 13Publication 1734-IN033B-EN-P - November 2010Default Data Map for the 1734-IE8C Analog Inp

Strona 6

14 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Wiring the Input Analog ModuleWiring Diagram

Strona 7 - Before You Begin

POINT I/O 8 Channel High Density Current Input Modules 15Publication 1734-IN033B-EN-P - November 2010 Interpret the Indicators Indicator State De

Strona 8 - Install the Mounting Base

16 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Network statusOff Device is not on-line- Devi

Strona 9 - Install the I/O Module

POINT I/O 8 Channel High Density Current Input Modules 17Publication 1734-IN033B-EN-P - November 2010Specifications IMPORTANTNote that the

Strona 10 - 1734-TOP Base

18 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Input impedance/resistance conversion type60

Strona 11 - Remove a Mounting Base

POINT I/O 8 Channel High Density Current Input Modules 19Publication 1734-IN033B-EN-P - November 2010General SpecificationsAttribute ValueModule l

Strona 12 - Remove a 1734-TOPS Base

2 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Important User Information Solid state equipme

Strona 13 - Message size: 24 Bytes

20 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Environmental SpecificationsAttribute ValueTe

Strona 14 - Wiring Diagram

POINT I/O 8 Channel High Density Current Input Modules 21Publication 1734-IN033B-EN-P - November 2010EFT/B immunity IEC 61000-4-4:±3 kV at 5 kHz o

Strona 15 - Interpret the Indicators

22 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Additional ResourcesThese documents contain a

Strona 16

POINT I/O 8 Channel High Density Current Input Modules 23Publication 1734-IN033B-EN-P - November 2010Notes:

Strona 17 - Specifications

Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwe

Strona 18 - Input Specifications

POINT I/O 8 Channel High Density Current Input Modules 3Publication 1734-IN033B-EN-P - November 2010Environment and Enclosure ATTENTIONThis equip

Strona 19 - General Specifications

4 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Prevent Electrostatic Discharge ATTENT

Strona 20 - Environmental Specifications

POINT I/O 8 Channel High Density Current Input Modules 5Publication 1734-IN033B-EN-P - November 2010European Hazardous Location Approval European

Strona 21 - Certifications

6 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010North American Hazardous Location Approval Th

Strona 22 - Additional Resources

POINT I/O 8 Channel High Density Current Input Modules 7Publication 1734-IN033B-EN-P - November 2010Before You BeginNote that this series C produc

Strona 23

8 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010 Install the Mounting BaseTo install the mount

Strona 24 - Installation Assistance

POINT I/O 8 Channel High Density Current Input Modules 9Publication 1734-IN033B-EN-P - November 2010Install the I/O ModuleThe module can be instal