Rockwell-automation 1734-OV2E_4E_8E POINT I/O Protected Sink Output Mo Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation 1734-OV2E_4E_8E POINT I/O Protected Sink Output Mo. Rockwell Automation 1734-OV2E_4E_8E POINT I/O Protected Sink Output Module Installation Instructions User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Publication 1734-IN585C-EN-E - December 2005
Installation Instructions
POINT I/O Protected Sink Output Module
Catalog Numbers 1734-OV2E, 1734-OV4E, and 1734-OV8E
Series C
Inside . . .
For See Page
Important User Information 2
Prevent Electrostatic Discharge 3
Environment and Enclosure 4
North American Hazardous Location Approval 5
About the Module 6
Install the Mounting Base 7
Install the Module 8
Install the Removable Terminal Block (RTB) 11
Remove a Mounting Base 12
Wire the Module 14
Configure the Module 18
Troubleshoot the Module 21
Specifications 23
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - Installation Instructions

Publication 1734-IN585C-EN-E - December 2005Installation InstructionsPOINT I/O Protected Sink Output ModuleCatalog Numbers 1734-OV2E, 1734-OV4E, and 1

Strona 2 - Important User Information

10 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 20053. Insert the module straight down into the mounting base. 4.

Strona 3

POINT I/O Protected Sink Output Module 11Publication 1734-IN585C-EN-E - December 2005Install the Removable Terminal Block (RTB)A removable termina

Strona 4 - Environment and Enclosure

12 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005Remove a Mounting Base To remove a module from the DIN rail,

Strona 5

POINT I/O Protected Sink Output Module 13Publication 1734-IN585C-EN-E - December 20054. Pull on the I/O module to remove from the base. 5. Repeat

Strona 6 - About the Module

14 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005Wire the ModuleRefer to the figures to wire the module.WARNIN

Strona 7 - Install the Mounting Base

POINT I/O Protected Sink Output Module 15Publication 1734-IN585C-EN-E - December 2005Output TerminalPower Common TerminalChannel 0 0 6 4Channel 1

Strona 8 - Install the Module

16 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005Output Termina lPower Common TerminalChannel 0 0 6Channel 1 1

Strona 9

POINT I/O Protected Sink Output Module 17Publication 1734-IN585C-EN-E - December 2005ChannelNumberOutput Termina lCommon Terminal PowerChannel 0 0

Strona 10 - The module locks into place

18 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005Configure the ModulePOINT I/O modules send (consume) and rece

Strona 11

POINT I/O Protected Sink Output Module 19Publication 1734-IN585C-EN-E - December 2005Default Data Map for the 1734-OV2E Output ModuleMessage size:

Strona 12 - Remove a Mounting Base

2 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005Important User InformationSolid state equipment has operationa

Strona 13 - ATTENTIO

20 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005Default Data Map for the 1734-OV8E Output ModuleMessage size:

Strona 14 - Wire the Module

POINT I/O Protected Sink Output Module 21Publication 1734-IN585C-EN-E - December 2005 Troubleshoot the Module Indication Probable Cause Recommend

Strona 15

22 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005 Indication Probable Cause Recommended ActionNetwork StatusOf

Strona 16

POINT I/O Protected Sink Output Module 23Publication 1734-IN585C-EN-E - December 2005Specifications 1734-OV2E/C, 1734-OV4E/C, and 1734-OV8E/C Prot

Strona 17

24 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005Module Location 1734-TB or 1734-TBS wiring base assemblyPOINT

Strona 18 - Configure the Module

POINT I/O Protected Sink Output Module 25Publication 1734-IN585C-EN-E - December 2005Pilot Duty Rating 24V dc 1.0 A North American Temperature Cod

Strona 19

26 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005Environmental SpecificationsSpecification ValueOperational Te

Strona 20

POINT I/O Protected Sink Output Module 27Publication 1734-IN585C-EN-E - December 2005Surge Transient ImmunityIEC 61000-4-5+1 kV line-line (DM) and

Strona 21 - Troubleshoot the Module

Publication 1734-IN585C-EN-E - December 2005 PN 957974-57Supersedes Publication 1734-IN585B-EN-P - March 2002 Copyright © 2005 Rockwell Automation, I

Strona 22

POINT I/O Protected Sink Output Module 3Publication 1734-IN585C-EN-E - December 2005Prevent Electrostatic DischargeATTENTIONThis equipment is sens

Strona 23 - Specifications

4 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005Environment and EnclosureATTENTIONThis equipment is intended f

Strona 24 - Protected Sink Output Modules

POINT I/O Protected Sink Output Module 5Publication 1734-IN585C-EN-E - December 2005North American Hazardous Location Approval The following infor

Strona 25

6 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005About the ModuleUse this series C module with the following:•

Strona 26 - Environmental Specifications

POINT I/O Protected Sink Output Module 7Publication 1734-IN585C-EN-E - December 2005Install the Mounting BaseTo install the mounting base on the D

Strona 27 - Certification

8 POINT I/O Protected Sink Output Module Publication 1734-IN585C-EN-E - December 2005Install the ModuleInstall the module before or after base inst

Strona 28 - Rockwell Automation Support

POINT I/O Protected Sink Output Module 9Publication 1734-IN585C-EN-E - December 2005To install the module on the DIN rail, proceed as follows. 1.

Komentarze do niniejszej Instrukcji

Brak uwag