Publication 1746-IN011C-EN-P - April 2005
Installation Instructions
High-Speed Counter Module
(Catalog Number 1746-HSCE)
Inside ................................................................................................Page
For More Information............................................................................... 3
Hazardous Location Considerations ........................................................ 4
Environnements dangereux ..................................................................... 4
High-Speed Counter Module Overview................................................... 5
Dip Switch and Jumper Locations........................................................... 6
Install the Module.................................................................................. 10
Remove the Terminal Block.................................................................... 11
Wire the Removable Terminal Block...................................................... 11
Important Wiring Considerations .......................................................... 12
Input and Output Connections ............................................................... 13
Outputs................................................................................................... 14
Encoders................................................................................................. 15
Single-Ended Wiring (Discrete Devices)................................................ 18
Limit Switch Wiring ............................................................................... 19
Specifications ........................................................................................ 20
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - High-Speed Counter Module

Publication 1746-IN011C-EN-P - April 2005Installation InstructionsHigh-Speed Counter Module(Catalog Number 1746-HSCE)Inside ...

Strona 2 - ATTENTION

10 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005Install the ModuleInstallation procedures for this module are the same as for

Strona 3 - For More Information

High-Speed Counter Module 11Publication 1746-IN011C-EN-P - April 2005Remove the Terminal BlockThe removable terminal wiring block eliminates the n

Strona 4 - Environnements dangereux

12 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005Important Wiring ConsiderationsUse the following guidelines when planning the

Strona 5

High-Speed Counter Module 13Publication 1746-IN011C-EN-P - April 2005Input and Output ConnectionsInput and output wiring terminals are located on

Strona 6

14 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005OutputsThe module features four physical outputs. They can be controlled by t

Strona 7

High-Speed Counter Module 15Publication 1746-IN011C-EN-P - April 2005EncodersThe wiring diagrams on the following pages are provided to support th

Strona 8 - SW1 Settings

16 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005Single-Ended Encoder Wiring (Open Collector)Single-Ended Encoder Output Wavef

Strona 9 - JW1 Settings

High-Speed Counter Module 17Publication 1746-IN011C-EN-P - April 2005Single-Ended Encoder Wiring (Sourcing)Single-Ended Encoder Output Waveforms (

Strona 10 - Module Release(s)

18 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005Single-Ended Wiring (Discrete Devices)IMPORTANT• This diagram shows the senso

Strona 11 - Remove the Terminal Block

High-Speed Counter Module 19Publication 1746-IN011C-EN-P - April 2005Limit Switch Wiring 24V dc Hard Contact12V dc Hard Contact5V dc Solid StateAT

Strona 12

2 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005Important User InformationSolid state equipment has operational characteristic

Strona 13 - OUTPUT INPUT

20 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005SpecificationsGeneralInputs A, B, and ZDescription SpecificationOperating Tem

Strona 14

High-Speed Counter Module 21Publication 1746-IN011C-EN-P - April 2005Limit Switch InputOutputs (Open Collector, Sinking)5V dc 12V dc 24V dcOn-Stat

Strona 15 - Differential Encoder Wiring

22 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005

Strona 16

High-Speed Counter Module 23Publication 1746-IN011C-EN-P - April 2005

Strona 17 - Module Inputs

Publication 1746-IN011C-EN-P - April 2005 PN 40071-130-01(3)Supersedes Publication 1746-IN011B-EN-P - April 1999 Copyright © 2007 Rockwell Automation,

Strona 18

High-Speed Counter Module 3Publication 1746-IN011C-EN-P - April 2005For More InformationRelated PublicationsTo view and download pdfs, go to Liter

Strona 19 - Limit Switch Wiring

4 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005Hazardous Location ConsiderationsThis equipment is suitable for use in Class I

Strona 20 - Specifications

High-Speed Counter Module 5Publication 1746-IN011C-EN-P - April 2005High-Speed Counter Module OverviewThe High-Speed Counter Module, Catalog Numbe

Strona 21 - Limit Switch Input

6 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005Dip Switch and Jumper LocationsTwo dip switches (SW1 and SW2) and one jumper (

Strona 22

High-Speed Counter Module 7Publication 1746-IN011C-EN-P - April 2005Default settings are shown below:ATTENTIONUse a small screwdriver to change di

Strona 23

8 High-Speed Counter ModulePublication 1746-IN011C-EN-P - April 2005SW2 SettingsSelect an output voltage range that coincides with your supply vol

Strona 24 - Rockwell Automation Support

High-Speed Counter Module 9Publication 1746-IN011C-EN-P - April 2005JW1 SettingsSelect 300 µs or 10 ms filtering to debounce the limit switch inpu

Komentarze do niniejszej Instrukcji