Publication 1746-IN007C-EN-P - December 2002
Installation Instructions
SLC 500™ RTD/Resistance Input Module
(Catalog Number 1746-NR8)
Inside… page
Important User Information ..................................................................... 2
For More Information ............................................................................... 3
Hazardous Location Considerations ....................................................... 4
Environnements dangereux .................................................................... 4
Hazardous Location Considerations ........................................................ 4
Required Tools and Equipment ................................................................ 6
Electrostatic Damage............................................................................... 7
Power Requirements................................................................................ 7
Modular Chassis Considerations ............................................................. 8
Fixed Expansion Chassis Considerations................................................. 8
General Considerations ........................................................................... 8
Module Installation and Removal............................................................ 9
Terminal Block Wiring and Removal...................................................... 10
Wiring Considerations ........................................................................... 11
Wiring Resistance Devices (Potentiometers) to the Module ................ 14
Wiring Input Devices to the NR8 Module ............................................. 15
Specifications ........................................................................................ 16
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - Installation Instructions

Publication 1746-IN007C-EN-P - December 2002Installation InstructionsSLC 500™ RTD/Resistance Input Module(Catalog Number 1746-NR8)Inside… pageImportan

Strona 2 - Important User Information

10 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 2002Terminal Block Wiring and RemovalThe RTD module contain

Strona 3 - For More Information

SLC 500™ RTD/Resistance Input Module 11Publication 1746-IN007C-EN-P - December 2002Terminal Block RemovalIf the terminal block is removed, u

Strona 4 - Environnements dangereux

12 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 20022 Wire Interconnection4 Wire Interconnection3 Wire Inte

Strona 5 - Overview

SLC 500™ RTD/Resistance Input Module 13Publication 1746-IN007C-EN-P - December 2002• To limit overall cable impedance, keep input cables as

Strona 6 - Required Tools and Equipment

14 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 2002Wiring Resistance Devices (Potentiometers) to the Modul

Strona 7 - Power Requirements

SLC 500™ RTD/Resistance Input Module 15Publication 1746-IN007C-EN-P - December 2002Wiring Input Devices to the NR8 ModuleTo wire your NR8 mo

Strona 8 - General Considerations

16 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 2002SpecificationsElectrical SpecificationsBackplane Curren

Strona 9 - Module Removal Procedure

SLC 500™ RTD/Resistance Input Module 17Publication 1746-IN007C-EN-P - December 2002Physical SpecificationsEnvironmental SpecificationsLED In

Strona 10 - Terminal Wiring

18 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 2002Input SpecificationsRTD Types platinum, nickel, nickel

Strona 11 - Wiring Considerations

SLC 500™ RTD/Resistance Input Module 19Publication 1746-IN007C-EN-P - December 2002RTD Temperature Ranges, Resolution, and RepeatabilityInpu

Strona 12 - 3 Wire Interconnection

2 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 2002Important User InformationBecause of the variety of uses

Strona 13

20 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 2002The module accuracy is dependent on the RTD/Resistance

Strona 14

SLC 500™ RTD/Resistance Input Module 21Publication 1746-IN007C-EN-P - December 2002RTD Accuracy and Temperature Drift SpecificationsInput Ty

Strona 15

22 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 2002Notes:

Strona 16 - Specifications

SLC 500™ RTD/Resistance Input Module 23Publication 1746-IN007C-EN-P - December 2002Notes:

Strona 17 - Environmental Specifications

Publication 1746-IN007C-EN-P - December 2002 PN 40071-091-01(3)Supersedes Publication 1746-IN007B-EN-P - May 2000 Copyright © 2002 Rockwell Automation

Strona 18 - Input Specifications

SLC 500™ RTD/Resistance Input Module 3Publication 1746-IN007C-EN-P - December 2002For More InformationRelated PublicationsHow to Get More In

Strona 19 - Ω per DIN standard

4 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 2002Hazardous Location ConsiderationsThis equipment is suita

Strona 20

SLC 500™ RTD/Resistance Input Module 5Publication 1746-IN007C-EN-P - December 2002OverviewThe RTD (Resistance Temperature Detector) module r

Strona 21

6 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 2002Required Tools and EquipmentHave the following tools and

Strona 22

SLC 500™ RTD/Resistance Input Module 7Publication 1746-IN007C-EN-P - December 2002Electrostatic DamageElectrostatic discharge can damage sem

Strona 23

8 SLC 500™ RTD/Resistance Input Module Publication 1746-IN007C-EN-P - December 2002Modular Chassis ConsiderationsPlace your RTD module in a

Strona 24

SLC 500™ RTD/Resistance Input Module 9Publication 1746-IN007C-EN-P - December 2002Module Installation and RemovalWhen installing the module

Komentarze do niniejszej Instrukcji

Brak uwag