Installation Instructions
ControlLogix-XT ControlNet Interface Module
Catalog Number 1756-CN2RXT
Topic Page
Important User Information 2
About the ControlLogix-XT ControlNet Module 6
About ControlLogix-XT Systems 8
ControlLogix-XT with Traditional ControlLogix Compone
nts 8
Using the 1756-CN2RXT for Standalone or Redundant Control 9
Example Redundant ControlLogix-XT System 10
Before You Begin 10
Parts 11
Set the Module’s Network Address 11
Reset the Module to the Original Factory Settings 12
Prepare the Chassis for Module Installation 13
Determine the Module Slot Location 13
Removal and Insertion Under Power (RIUP) 14
Install the ControlNet Module 14
Connect the Module to the Network 16
Remove the Module 19
Install the EDS File 20
Configure RSLinx Software to Use the USB Port 21
Set Up the USB Driver 22
Status Indicators 23
Module Status Indicator and Display 23
Channel Status Indicators 29
General Specifications - 1756-CN2RXT 31
Environmental Specifications - 1756-CN2RXT 32
Certifications - 1756-CN2RXT 34
Additional Resources 35
Przeglądanie stron 0
1 2 3 4 5 6 ... 35 36

Podsumowanie treści

Strona 1 - Installation Instructions

Installation InstructionsControlLogix-XT ControlNet Interface ModuleCatalog Number 1756-CN2RXTTopic PageImportant User Information 2About the ControlL

Strona 2 - Important User Information

10 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Example Redundant ControlLogix-XT SystemThis example of a r

Strona 3 - Environment and Enclosure

ControlLogix-XT ControlNet Interface Module 11Publication 1756-IN634A-EN-P - April 2009PartsTo use your ControlNet module, you need these system c

Strona 4

12 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Reset the Module to the Original Factory SettingsIf you nee

Strona 5

ControlLogix-XT ControlNet Interface Module 13Publication 1756-IN634A-EN-P - April 2009Prepare the Chassis for Module InstallationComplete these t

Strona 6

14 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Removal and Insertion Under Power (RIUP)Install the Control

Strona 7

ControlLogix-XT ControlNet Interface Module 15Publication 1756-IN634A-EN-P - April 20093. Make sure the module backplane connector properly connec

Strona 8 - About ControlLogix-XT Systems

16 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Connect the Module to the NetworkConnect the module to the

Strona 9

ControlLogix-XT ControlNet Interface Module 17Publication 1756-IN634A-EN-P - April 20092. Attach the tap’s straight or right-angle connector to th

Strona 10 - Before You Begin

18 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Apply Power and Check StatusIf not yet applied, apply power

Strona 11

ControlLogix-XT ControlNet Interface Module 19Publication 1756-IN634A-EN-P - April 2009Remove the ModuleTo remove the module, perform this procedu

Strona 12 - IMPORTANT

2 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Important User InformationSolid state equipment has operatio

Strona 13

20 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Install the EDS FileThe EDS file can be uploaded directly f

Strona 14 - Install the ControlNet Module

ControlLogix-XT ControlNet Interface Module 21Publication 1756-IN634A-EN-P - April 2009Configure RSLinx Software to Use the USB PortThe ControlNet

Strona 15 - ATTENTION

22 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Set Up the USB DriverTo configure RSLinx software to use a

Strona 16

ControlLogix-XT ControlNet Interface Module 23Publication 1756-IN634A-EN-P - April 2009Status IndicatorsThe ControlLogix-XT ControlNet module has

Strona 17 - Publication

24 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Red Reset Complete- Change Switch SettingsModule’s network

Strona 18 - Apply Power and Check Status

ControlLogix-XT ControlNet Interface Module 25Publication 1756-IN634A-EN-P - April 2009Flashing redImage update NeededBoot image running. Main fi

Strona 19 - Remove the Module

26 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Solid greenOK This is normal operation. There is at least o

Strona 20 - Install the EDS File

ControlLogix-XT ControlNet Interface Module 27Publication 1756-IN634A-EN-P - April 2009Solid or flashing greenCPU=XX% This message is the CPU util

Strona 21

28 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Any Keeper: UnconfiguredThe network configuration data main

Strona 22 - Set Up the USB Driver

ControlLogix-XT ControlNet Interface Module 29Publication 1756-IN634A-EN-P - April 2009Channel Status IndicatorsThe ControlNet channel status indi

Strona 23 - Status Indicators

ControlLogix-XT ControlNet Interface Module 3Publication 1756-IN634A-EN-P - April 2009Environment and EnclosureATTENTIONThis equipment is intended

Strona 24

30 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009ControlNet Indicator States (A AND B)State Cause ActionOff

Strona 25

ControlLogix-XT ControlNet Interface Module 31Publication 1756-IN634A-EN-P - April 2009General Specifications - 1756-CN2RXTAttribute ValueControlN

Strona 26

32 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Environmental Specifications - 1756-CN2RXT Attribute ValueT

Strona 27

ControlLogix-XT ControlNet Interface Module 33Publication 1756-IN634A-EN-P - April 2009Radiated RF ImmunityIEC 61000-4-3•10V/m with 1 kHz sine-wav

Strona 28

34 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Certifications - 1756-CN2RXTCertification(1) (2)(1)When the

Strona 29 - Channel Status Indicators

ControlLogix-XT ControlNet Interface Module 35Publication 1756-IN634A-EN-P - April 2009Additional ResourcesThese documents contain additional info

Strona 30

Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwe

Strona 31

4 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009North American Hazardous Location ApprovalThe following info

Strona 32 - • 8 kV air discharges

ControlLogix-XT ControlNet Interface Module 5Publication 1756-IN634A-EN-P - April 2009European Hazardous Location ApprovalEuropean Zone 2 Certific

Strona 33

6 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009Preventing Electrostatic DischargeAbout the ControlLogix-XT

Strona 34 - Certifications - 1756-CN2RXT

ControlLogix-XT ControlNet Interface Module 7Publication 1756-IN634A-EN-P - April 2009Features of the 1756-CN2RXT ModuleThese are the hardware fea

Strona 35 - Additional Resources

8 ControlLogix-XT ControlNet Interface Module Publication 1756-IN634A-EN-P - April 2009About ControlLogix-XT SystemsThe ControlLogix-XT products in

Strona 36 - Rockwell Automation Support

ControlLogix-XT ControlNet Interface Module 9Publication 1756-IN634A-EN-P - April 2009Using the 1756-CN2RXT for Standalone or Redundant ControlYou

Komentarze do niniejszej Instrukcji