Installation Instructions
ControlLogix EtherNet/IP Module
Catalog Number 1756-EN2T
About This Publication
Use this publication as a guide to install the module. This publication describes
hardware installation only. For configuration information, refer to the
EtherNet/IP Modules in Logix5000 Control Systems User Manual, publication
ENET-UM001
. View or download this publication at
http://www.rockwellautomation.com/literature.
Topic Page
About This Publication 1
Before You Begin 7
Determine Module Slot Location 8
Set the Network Address 9
Install the Module 11
Connect the Module to the EtherNet/IP Network 12
Program the Module via the USB Port 14
Configure the Module 15
Apply Chassis Power 15
Check Power Supply and Module Status 16
Install or Remove the Module Under Power 17
Interpret the Status Indicators 19
Specifications 22
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - Installation Instructions

Installation InstructionsControlLogix EtherNet/IP ModuleCatalog Number 1756-EN2TAbout This PublicationUse this publication as a guide to install the

Strona 2 - Important User Information

10 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010To reset the module to its initial out-of-the-box

Strona 3

ControlLogix EtherNet/IP Module 11Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Install the ModuleFollow this procedure to install

Strona 4 - Environment and Enclosure

12 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Make sure that the module backplane connector prop

Strona 5

ControlLogix EtherNet/IP Module 13Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Item Description Item Description1 USB port 2 RJ45

Strona 6 - About the Module

14 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Program the Module via the USB PortBe sure that po

Strona 7 - Before You Begin

ControlLogix EtherNet/IP Module 15Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Configure the ModuleFollow these steps to configure

Strona 8 - 3 Slot 2 6 Power supply

16 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Check Power Supply and Module StatusCheck the stat

Strona 9 - Set the Network Address

ControlLogix EtherNet/IP Module 17Rockwell Automation Publication 1756-IN603C-EN-P - April 2010The alphanumeric display should cycle through these

Strona 10

18 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 20102. Slide the module out of the chassis.IMPORTANTIf

Strona 11 - Install the Module

ControlLogix EtherNet/IP Module 19Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Interpret the Status IndicatorsIf the alphanumeric

Strona 12

2 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Important User InformationSolid-state equipment has

Strona 13

20 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Status IndicatorsIndicator Status DescriptionNET O

Strona 14

ControlLogix EtherNet/IP Module 21Rockwell Automation Publication 1756-IN603C-EN-P - April 2010OK Off Verify that the module has 24V DC chassis po

Strona 15 - Apply Chassis Power

22 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010SpecificationsTechnical Specifications - 1756-EN2T

Strona 16 - LINK NET OK

ControlLogix EtherNet/IP Module 23Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Environmental Specifications - 1756-EN2TAttribute 1

Strona 17

24 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Immunity, conducted RF• IEC 61000-4-610V rms with

Strona 18 - IMPORTANT

ControlLogix EtherNet/IP Module 25Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Additional ResourcesThese documents contain additio

Strona 19

26 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Notes:

Strona 20 - Status Indicators

ControlLogix EtherNet/IP Module 27Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Notes:

Strona 21

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400Rockwell Automation SupportRockwel

Strona 22 - Specifications

ControlLogix EtherNet/IP Module 3Rockwell Automation Publication 1756-IN603C-EN-P - April 2010North American Hazardous Location ApprovalThe follow

Strona 23

4 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Environment and EnclosureATTENTION: This equipment

Strona 24 - Certifications - 1756-EN2T

ControlLogix EtherNet/IP Module 5Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Prevent Electrostatic DischargeATTENTION: This equip

Strona 25 - Additional Resources

6 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010About the ModuleUse this figure to identify the ext

Strona 26

ControlLogix EtherNet/IP Module 7Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Before You BeginBefore you install the module, you m

Strona 27

8 ControlLogix EtherNet/IP Module Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Determine Module Slot LocationInstall the module in

Strona 28 - Automation, Inc

ControlLogix EtherNet/IP Module 9Rockwell Automation Publication 1756-IN603C-EN-P - April 2010Set the Network AddressThe module ships with the rot

Komentarze do niniejszej Instrukcji

Brak uwag