Rockwell-automation 1756-HSC ControlLogix High Speed Counter Module Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation 1756-HSC ControlLogix High Speed Counter Module. Rockwell Automation 1756-HSC ControlLogix High Speed Counter Module User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 128
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - User Manual

ControlLogix High-speed Counter ModuleCatalog Numbers 1756-HSCUser Manual

Strona 2 - Important User Information

10 Publication 1756-UM007C-EN-P - November 2011Preface Additional ResourcesThese documents provide information related to the ControlLogix High

Strona 3 - Information

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011100 1756-HSC Module History2. Double-click the .ACD file to access the ladder logi

Strona 4 - 4 Summary of Changes

Rockwell Automation Publication 1756-UM007C-EN-P - November 20111756-HSC Module History 101The optional rung below will coordinate the values ente

Strona 5 - Table of Contents

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011102 1756-HSC Module History4. Re-enter the 1756-HSC module configuration data that

Strona 6 - 6 Table of Contents

Rockwell Automation Publication 1756-UM007C-EN-P - November 20111756-HSC Module History 103Follow these steps to manually enter tag data.1. On the

Strona 7 - Table of Contents 7

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011104 1756-HSC Module HistoryChange ConfigurationData via MessageInstructionLadder l

Strona 8 - 8 Table of Contents

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Appendix DApplication ConsiderationsIntroductionThis appendix provides background for

Strona 9 - This Manual

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011106 Application ConsiderationsExamples for Selecting Input DevicesThe following ex

Strona 10 - Additional Resources

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Application Considerations 107The previous calculation is necessary because the dr

Strona 11 - 1756-HSC Module Features

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011108 Application ConsiderationsThus, Vdrop never exceeds about 2.0V regardless of t

Strona 12

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Application Considerations 109Assuming that you could supply 5 mA to the 1756-HSC

Strona 13 - Features

11Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Chapter 11756-HSC Module FeaturesIntroductionThe High-speed Counter Module (catalog

Strona 14

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011110 Application Considerations If a 24V supply is used, and this driver supplies 1

Strona 15 - 1756-HSC Parts Illustration

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Application Considerations 111Choosing input terminals provides some options, as s

Strona 16

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011112 Application ConsiderationsIn either case, this example is similar to the Open

Strona 17 - Counter Modes

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Application Considerations 113Application ConsiderationsA successful installation

Strona 18 - Encoder x4

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011114 Application ConsiderationsCable ImpedanceGenerally, you want the cable impedan

Strona 19 - Counter Mode

Publication 1756-UM007C-EN-P - November 2011Glossaryaccumulated value (ACC) The number of elapsed time intervals or counted events.actuator 1) A devic

Strona 20 - Encoder Mode

Publication 1756-UM007C-EN-P - November 2011116 Glossarybus A single path or multiple parallel paths for power or data signals to which several de

Strona 21

Publication 1756-UM007C-EN-P - November 2011Glossary 117data 1) A general term for any type of information. 2) In a more restricted sense, data re

Strona 22 - Rollover

Publication 1756-UM007C-EN-P - November 2011118 Glossary• Rotary encoder—is a feedback element that converts rotary position (absolute or incremen

Strona 23 - Storage Modes

Publication 1756-UM007C-EN-P - November 2011Glossary 119interval 1) The length of time between events or states. For example, the length of time b

Strona 24 - Store, Wait, and Resume

Rockwell Automation Publication 1756-UM007C-EN-P - November 201112 1756-HSC Module FeaturesThis user manual also details the Frequency operatio

Strona 25 - Store and Reset, and Start

Publication 1756-UM007C-EN-P - November 2011120 Glossaryoutput device 1) For a computer, a CRT terminal or printer. 2) For a programmable controll

Strona 26 - Output Operation

Publication 1756-UM007C-EN-P - November 2011Glossary 121sensor A digital or analog transducer (a device such as a limit switch, push button switch

Strona 27 - Tying Outputs to Counters

Publication 1756-UM007C-EN-P - November 2011122 Glossary

Strona 28 - 28 Counter Modes

123Rockwell Automation Publication 1756-UM010B-EN-P - November 2011IndexNumerics1756-TBCH cage clamp RTB 461756-TBE extended housing 471756-TBS6H spri

Strona 29 - Frequency Modes

124Rockwell Automation Publication 1756-UM010B-EN-P - November 2011124 Indexfrequencycalculation sample period 31, 33continuous rate 32modeHSC

Strona 30 - Frequency Mode

125Rockwell Automation Publication 1756-UM010B-EN-P - November 2011Index 125removable terminal block (RTB)1756-TBCH cage clamp 461756-TBE exten

Strona 31

126Rockwell Automation Publication 1756-UM010B-EN-P - November 2011126 Index

Strona 33

Publication 1756-UM007C-EN-P - November 2011 Supersedes Publication 1756-UM007B-EN-P - October 2009 Copyright © 2011 Rockwell Automation, Inc. All ri

Strona 34 - 34 Frequency Modes

Rockwell Automation Publication 1756-UM007C-EN-P - November 20111756-HSC Module Features 13Encoder and Sensor CompatibilityThe most common appl

Strona 35

Rockwell Automation Publication 1756-UM007C-EN-P - November 201114 1756-HSC Module FeaturesAdditional I/O Module FeaturesThe following items ar

Strona 36 - Rate Output Examples

Rockwell Automation Publication 1756-UM007C-EN-P - November 20111756-HSC Module Features 151756-HSC Parts IllustrationSee page 46 for details o

Strona 37 - Maximum Frequency

Rockwell Automation Publication 1756-UM007C-EN-P - November 201116 1756-HSC Module FeaturesNotes:

Strona 38 - 38 Frequency Modes

17Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Chapter 2Counter ModesIntroductionThis chapter describes the Counter modes for the 1

Strona 39 - High-speed Counter Module

Rockwell Automation Publication 1756-UM007C-EN-P - November 201118 Counter Modes• Encoder x1- This is a Bidirectional Count mode, counting up o

Strona 40 - ATTENTION

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Counter Modes 19Counter ModeThis is the 1756-HSC module’s default operational m

Strona 41 - Install the 1756-HSC

Important User InformationSolid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Strona 42 - Terminal Block

Rockwell Automation Publication 1756-UM007C-EN-P - November 201120 Counter ModesEncoder ModeEncoder mode also counts incoming pulses. However,

Strona 43

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Counter Modes 21Encoder x4Encoder x4 mode is identical to x1, except this mode

Strona 44 - Connect the Wires

Rockwell Automation Publication 1756-UM007C-EN-P - November 201122 Counter ModesPresetEach of the two counters has one preset value associated

Strona 45

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Counter Modes 23Rollover in Output tagWhen using the HSC Data-extended Comm For

Strona 46

Rockwell Automation Publication 1756-UM007C-EN-P - November 201124 Counter ModesStore and Continue ModeIn the Store and Continue mode, the modu

Strona 47 - Wire Terminations

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Counter Modes 25Store and Reset, Wait, and StartIn the Store and Reset, Wait, a

Strona 48

Rockwell Automation Publication 1756-UM007C-EN-P - November 201126 Counter ModesOutputsThe module has four outputs, isolated in pairs (0 and 1,

Strona 49

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Counter Modes 27For example, the ‘Output Turns ON’ tag is set for a value of 20

Strona 50 - Terminal Block and

Rockwell Automation Publication 1756-UM007C-EN-P - November 201128 Counter ModesNotes:

Strona 51 - Install the Removable

29Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Chapter 3Frequency ModesIntroductionThis chapter describes the frequency modes that

Strona 52 - Remove the Removable

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Summary of ChangesThis manual contains new and updated information. Changes throughout

Strona 53 - Remove the Module

Rockwell Automation Publication 1756-UM007C-EN-P - November 201130 Frequency ModesThe difference between the Period Rate and Continuous Rate mo

Strona 54

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Frequency Modes 31Sample Period for Frequency ModeAs previously mentioned, the

Strona 55 - Configure the 1756-HSC Module

Rockwell Automation Publication 1756-UM007C-EN-P - November 201132 Frequency ModesPeriod Rate andContinuous Rate ModesThese two Frequency-opera

Strona 56 - Direct Connections

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Frequency Modes 33As the frequency of the incoming pulse train increases, the n

Strona 57 - Remote Chassis Operation

Rockwell Automation Publication 1756-UM007C-EN-P - November 201134 Frequency ModesThe inverse relationship of the increase in frequency and dec

Strona 58

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Frequency Modes 35Output OperationThe Period Rate and Continuous Rate frequency

Strona 59 - Version 18 and Later

Rockwell Automation Publication 1756-UM007C-EN-P - November 201136 Frequency ModesPeriod Rate /Continuous Rate Output ExamplesThe following squ

Strona 60

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Frequency Modes 37Maximum FrequencyA module is capable of counting up to 16 mil

Strona 61

Rockwell Automation Publication 1756-UM007C-EN-P - November 201138 Frequency ModesNotes:

Strona 62 - Communication Format Options

39Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Chapter 4Install and Wire the ControlLogixHigh-speed Counter ModuleIntroductionThis

Strona 63

Rockwell Automation Publication 1756-UM007C-EN-P - November 20114 Summary of ChangesNotes:

Strona 64

Rockwell Automation Publication 1756-UM007C-EN-P - November 201140 Install and Wire the ControlLogix High-speed Counter ModuleNorth American Ha

Strona 65 - Configuration

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Install and Wire the ControlLogix High-speed Counter Module 41Install the 1756-

Strona 66

Rockwell Automation Publication 1756-UM007C-EN-P - November 201142 Install and Wire the ControlLogix High-speed Counter Module2. Slide the modu

Strona 67

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Install and Wire the ControlLogix High-speed Counter Module 431. Insert the U-s

Strona 68 - Set Up Output Configuration

Rockwell Automation Publication 1756-UM007C-EN-P - November 201144 Install and Wire the ControlLogix High-speed Counter ModuleWiring the Module

Strona 69

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Install and Wire the ControlLogix High-speed Counter Module 455. Connect the dr

Strona 70 - 3. Click OK

Rockwell Automation Publication 1756-UM007C-EN-P - November 201146 Install and Wire the ControlLogix High-speed Counter ModuleTwo Types of RTBs

Strona 71 - Tags to Output (.O) Tags

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Install and Wire the ControlLogix High-speed Counter Module 47Recommendations f

Strona 72

Rockwell Automation Publication 1756-UM007C-EN-P - November 201148 Install and Wire the ControlLogix High-speed Counter ModuleWire an Allen-Bra

Strona 73 - Electronic Keying

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Install and Wire the ControlLogix High-speed Counter Module 49Wire a PHOTOSWITC

Strona 74 - Exact Match

Publication 1756-UM007C-EN-P - November 2011Table of ContentsPrefaceAbout This Publication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 75 - Compatible Keying

Rockwell Automation Publication 1756-UM007C-EN-P - November 201150 Install and Wire the ControlLogix High-speed Counter ModuleAssemble the Remo

Strona 76

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Install and Wire the ControlLogix High-speed Counter Module 51Install the Remov

Strona 77 - Disabled Keying

Rockwell Automation Publication 1756-UM007C-EN-P - November 201152 Install and Wire the ControlLogix High-speed Counter Module3. Slide the lock

Strona 78

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Install and Wire the ControlLogix High-speed Counter Module 533. Hold the spot

Strona 79 - Download Configuration

Rockwell Automation Publication 1756-UM007C-EN-P - November 201154 Install and Wire the ControlLogix High-speed Counter Module1. Push in the t

Strona 80 - 3. Click Download

55Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Chapter 5Configure the 1756-HSC ModuleIntroductionThis chapter describes how to conf

Strona 81 - Module Diagnostics

Rockwell Automation Publication 1756-UM007C-EN-P - November 201156 Configure the 1756-HSC ModuleA remote chassis, also known as a networked cha

Strona 82 - RSLogix 5000 Diagnostics

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 57One of the following events occurs:• If the dat

Strona 83 - Notification in Tag Editor

Rockwell Automation Publication 1756-UM007C-EN-P - November 201158 Configure the 1756-HSC ModuleThe timing of this ‘reserved’ spot may not coin

Strona 84 - Troubleshoot the 1756-HSC

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 59Use the Default Configuration1756-HSC modules i

Strona 85 - 1756-HSC Status Indicators

Publication 1756-UM007C-EN-P - November 20116 Table of ContentsTwo Types of RTBs (each RTB comes with housing) . . . . . . . . . 46Recommendation

Strona 86

Rockwell Automation Publication 1756-UM007C-EN-P - November 201160 Configure the 1756-HSC ModuleThe Select Module dialog box appears.2. Click t

Strona 87 - 1756-HSC Data Structures

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 617. From the Comm Format pull-down menu, choose

Strona 88

Rockwell Automation Publication 1756-UM007C-EN-P - November 201162 Configure the 1756-HSC ModuleCommunication Format OptionsMultiple controller

Strona 89 - Output Structure

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 63The table lists the mode number and assigned ta

Strona 90

Rockwell Automation Publication 1756-UM007C-EN-P - November 201164 Configure the 1756-HSC ModuleSet RPIThe Connection tab on the Module Propert

Strona 91 - Input Structure

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 652. Click OK.Set Up Counter ConfigurationThe Cou

Strona 92

Rockwell Automation Publication 1756-UM007C-EN-P - November 201166 Configure the 1756-HSC ModuleThe Counter Configuration dialog box appears.Th

Strona 93 - 1756-HSC Module History

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 67Storage Mode Choose how the pulse count will be

Strona 94 - 1756-HSC Profile Overview

Rockwell Automation Publication 1756-UM007C-EN-P - November 201168 Configure the 1756-HSC Module3. Click OK.Filter SelectionsHigh-speed inputs

Strona 95 - Configure a Generic Profile

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 69The Output Configuration dialog box appears.2.

Strona 96 - Connection Parameters

Publication 1756-UM007C-EN-P - November 2011Table of Contents 7Configuration Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 97

Rockwell Automation Publication 1756-UM007C-EN-P - November 201170 Configure the 1756-HSC Module3. Click OK.First Value Output Turns ON Type va

Strona 98 - Copy ACD file

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 71Copy Configuration (.C) Output, Rollover, Prese

Strona 99 - Add Ladder Logic Routines

Rockwell Automation Publication 1756-UM007C-EN-P - November 201172 Configure the 1756-HSC Module5. Type the following information:Source -- Loc

Strona 100 - IMPORTANT

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 73Electronic KeyingWhen you create a new module,

Strona 101

Rockwell Automation Publication 1756-UM007C-EN-P - November 201174 Configure the 1756-HSC ModuleYou can find revision information on the Genera

Strona 102 - Edit Thin Profile Tags

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 75Exact Match keying is also necessary to enable

Strona 103

Rockwell Automation Publication 1756-UM007C-EN-P - November 201176 Configure the 1756-HSC ModuleCompatible Keying is the default setting. Compa

Strona 104 - Instruction

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 77Disabled KeyingDisabled Keying indicates the ke

Strona 105 - Application Considerations

Rockwell Automation Publication 1756-UM007C-EN-P - November 201178 Configure the 1756-HSC ModuleIf you use Disabled Keying, you must take full

Strona 106 - Examples for Selecting

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Configure the 1756-HSC Module 79Download Configurationto the 1756-HSC ModuleAft

Strona 107 - Detailed Circuit Analysis

Publication 1756-UM007C-EN-P - November 20118 Table of Contents

Strona 108

Rockwell Automation Publication 1756-UM007C-EN-P - November 201180 Configure the 1756-HSC ModuleThe Download dialog box appears. 3. Click Downl

Strona 109

81Publication 1756-UM007C-EN-P - November 2011Chapter 6Module DiagnosticsIntroductionThis chapter describes error codes and fault conditions to help y

Strona 110 - Open Collector

Publication 1756-UM007C-EN-P - November 201182 Module DiagnosticsRSLogix 5000 DiagnosticsIn addition to the Status Indicator display on the mod

Strona 111 -  pull-up impedance

Publication 1756-UM007C-EN-P - November 2011Module Diagnostics 83The following windows display fault notification in RSLogix 5000 software.Warn

Strona 112 - Output Circuits

Publication 1756-UM007C-EN-P - November 201184 Module DiagnosticsFault Type DeterminationWhen you are monitoring a module’s configuration prope

Strona 113

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Appendix A1756-HSC Status IndicatorsIntroductionEach 1756-HSC module has indicators th

Strona 114 - Cable Length and Frequency

Rockwell Automation Publication 1756-UM007C-EN-P - November 201186 1756-HSC Status IndicatorsNotes:

Strona 115 - Glossary

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Appendix B1756-HSC Data StructuresConfiguration,Output,InputThere are three categories

Strona 116 - 116 Glossary

Rockwell Automation Publication 1756-UM007C-EN-P - November 201188 1756-HSC Data StructuresC.Preset[x]DINT Decimal Designates the Preset value. M

Strona 117 - Glossary 117

Rockwell Automation Publication 1756-UM007C-EN-P - November 20111756-HSC Data Structures 89Output StructureYou must use output tags to change modu

Strona 118 - 118 Glossary

9Publication 1756-UM007C-EN-P - November 2011 9PrefaceAbout This PublicationThe 1756 High-speed Counter module counts incoming pulses from pulse gener

Strona 119 - Glossary 119

Rockwell Automation Publication 1756-UM007C-EN-P - November 201190 1756-HSC Data StructuresO.LoadPreset.x BOOL Decimal Loads preset count value in

Strona 120 - 120 Glossary

Rockwell Automation Publication 1756-UM007C-EN-P - November 20111756-HSC Data Structures 91Input StructureYou must use input tags to monitor modul

Strona 121 - Glossary 121

Rockwell Automation Publication 1756-UM007C-EN-P - November 201192 1756-HSC Data StructuresNotes:

Strona 122 - 122 Glossary

Rockwell Automation Publication 1756-UM007C-EN-P - November 2011Appendix C1756-HSC Module HistoryIntroductionThis appendix describe’s Logix5000 profil

Strona 123

Rockwell Automation Publication 1756-UM007C-EN-P - November 201194 1756-HSC Module History1756-HSC Profile OverviewThere are three profiles availa

Strona 124 - 124 Index

Rockwell Automation Publication 1756-UM007C-EN-P - November 20111756-HSC Module History 95Configure a Generic ProfileYou will use a generic profil

Strona 125 - Index 125

Rockwell Automation Publication 1756-UM007C-EN-P - November 201196 1756-HSC Module HistoryThe New Module dialog box appears.5. Type a name for the

Strona 126 - 126 Index

Rockwell Automation Publication 1756-UM007C-EN-P - November 20111756-HSC Module History 978. Enter Connection Parameters exactly as shown in the e

Strona 127

Rockwell Automation Publication 1756-UM007C-EN-P - November 201198 1756-HSC Module History14. Click OK.The ladder logic in your RSLogix 5000 proje

Strona 128 - Documentation Feedback

Rockwell Automation Publication 1756-UM007C-EN-P - November 20111756-HSC Module History 99b. Click the ‘+’ sign to expand and review each of the t

Komentarze do niniejszej Instrukcji

Brak uwag