Rockwell-automation 1771-OBDS DC(10-40V)Current Limiting Input Module Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation 1771-OBDS DC(10-40V)Current Limiting Input Module . Rockwell Automation 1771-OBDS DC(10-40V)Current Limiting Input Module Installation Instructions User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Publication 1771ĆIN033B-EN-P - July 2002
DC (10Ć40V) Current Limiting
Output Module
Cat. No. 1771ĆOBDS
Use this document as a guide when installing the catalog number
1771-OBDS output module.
For information on: See page
Important User Information 1
Preinstallation Considerations 4
Calculate Power Requirements 4
Set the Fault Mode Selection Jumper 4
Key the Backplane Connector 5
Install the Module and Field Wiring Arm 6
Connect Wiring to the Output Module 7
Short Circuit Protection 10
Replacing the Fuse 11
For this reference information See page
Intepreting the Status Indicators 10
Hazardous Location Approval 12
Specifications 13
Because of the variety of uses for the products described in this
publication, those responsible for the application and use of these
products must satisfy themselves that all necessary steps have been
taken to assure that each application and use meets all performance
and safety requirements, including any applicable laws, regulations,
codes and standards. In no event will Rockwell Automation be
responsible or liable for indirect or consequential damage resulting
from the use or application of these products.
Any illustrations, charts, sample programs, and layout examples
shown in this publication are intended solely for purposes of
example. Since there are many variables and requirements associated
with any particular installation, Rockwell Automation does not
assume responsibility or liability (to include intellectual property
liability) for actual use based upon the examples shown in this
publication.
Important User Information
Installation Instructions
To The Installer
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Output Module

Publication 1771ĆIN033B-EN-P - July 2002DC (10Ć40V) Current LimitingOutput ModuleCat. No. 1771ĆOBDSUse this document as a guide when installing the ca

Strona 2

DC (10-40V) Current Limiting Output Module10Publication 1771ĆIN033B-EN-P - July 2002Each output of the module is capable of withstanding a short circ

Strona 3

DC (10-40V) Current Limiting Output Module 11Publication 1771ĆIN033B-EN-P - July 2002The individual output transistors are thermally protected agains

Strona 4 - LS RESET

DC (10-40V) Current Limiting Output Module12Publication 1771ĆIN033B-EN-P - July 2002The following information applies when operating this equipment i

Strona 5 - Connector

DC (10-40V) Current Limiting Output Module 13Publication 1771ĆIN033B-EN-P - July 2002Outputs per Module 16Module Location 1771ĆA1B, thru ĆA4B or late

Strona 6 - Wiring Arm

DC (10-40V) Current Limiting Output Module14Publication 1771ĆIN033B-EN-P - July 2002Keying Between 10 and 12Between 22 and 24Fuse 12A, 250V rectifier

Strona 7 - Connect Wiring to the

DC (10-40V) Current Limiting Output Module 15Publication 1771ĆIN033B-EN-P - July 2002Derating Curve for the 1771-OBDS0123456789010 203040 5060Tempera

Strona 8

DC (10-40V) Current Limiting Output Module16Publication 1771ĆIN033B-EN-P - July 2002Publication 1771ĆIN033B-EN-P - July 2002Supersedes publication 17

Strona 9

DC (10-40V) Current Limiting Output Module2Publication 1771ĆIN033B-EN-P - July 2002Allen–Bradley publication SGI–1.1, Safety Guidelines forApplicatio

Strona 10 - Indicators

DC (10-40V) Current Limiting Output Module 3Publication 1771ĆIN033B-EN-P - July 2002ATTENTION!Environment and EnclosureThis equipment is intended for

Strona 11 - Replacing the Fuse

DC (10-40V) Current Limiting Output Module4Publication 1771ĆIN033B-EN-P - July 2002!ATTENTIONPreventing Electrostatic DischargeThis equipment is sens

Strona 12 - AVERTISSEMENT

DC (10-40V) Current Limiting Output Module 5Publication 1771ĆIN033B-EN-P - July 2002!ATTENTIONA module inserted into a wrong slot could bedamaged by

Strona 13 - Specifications

DC (10-40V) Current Limiting Output Module6Publication 1771ĆIN033B-EN-P - July 2002!WARNINGWhen you insert or remove the module whilebackplane power

Strona 14

DC (10-40V) Current Limiting Output Module 7Publication 1771ĆIN033B-EN-P - July 2002!ATTENTIONRemove power from the 1771 I/O chassisbackplane and fie

Strona 15 - Temperature (

DC (10-40V) Current Limiting Output Module8Publication 1771ĆIN033B-EN-P - July 2002Actual wiring runs in this direction.Output 00Output 01Output 02Ou

Strona 16 - PN957689-07

DC (10-40V) Current Limiting Output Module 9Publication 1771ĆIN033B-EN-P - July 2002IMPORTANTYou can use a DC (10-40V) Output Module (cat.no. 1771-OB

Komentarze do niniejszej Instrukcji

Brak uwag