EtherNet/IP and ControlNet to PROFIBUS PA Linking Devices
Catalog Numbers 1788-EN2PAR, 1788-CN2PAR
User Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 75 76

Podsumowanie treści

Strona 1 - User Manual

EtherNet/IP and ControlNet to PROFIBUS PA Linking DevicesCatalog Numbers 1788-EN2PAR, 1788-CN2PARUser Manual

Strona 2 - Important User Information

10 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014PrefaceBuilt-in power conditioners and protection help to minimize installation sp

Strona 3 - Table of Contents

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 11PrefaceEnvironment and EnclosureATTENTION: Environment and Enclosure• This equipme

Strona 4

12 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014PrefaceEuropean Hazardous Location ApprovalThe following applies when the product

Strona 5 - Glossary

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 13PrefaceNorth American Hazardous Location ApprovalThe following information applies

Strona 6

14 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014PrefaceAdditional ResourcesThese documents contain more information about related

Strona 7 - Introduction

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 15Chapter 1InstallationHardwareDimensionsPower ConnectionTo comply with the CE Low V

Strona 8 - Network Diagrams

16 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 1 InstallationWe re co mmend a 2 4…32V DC power supply for the linking d

Strona 9 - Features

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 17Installation Chapter 1The PA network connections are described here.

Strona 10 - General Precautions

18 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 1 InstallationControlNet and EtherNet/IP ConnectionsTwo BNC (Bayonet Neill

Strona 11 - Environment and Enclosure

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 19Installation Chapter 1See Grounding/Earthing on page 19 for more details for shiel

Strona 12

Important User InformationRead this document and the documents listed in the additional resources section about installation, configuration, and opera

Strona 13

20 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 1 InstallationCable PathDo not route the PROFIBUS PA cable near any motors

Strona 14 - Additional Resources

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 21Installation Chapter 1Cable Type and Minimum RequirementsPer section 12.8.2 of IEC

Strona 15 - Installation

22 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 1 InstallationSet the Linking Device Network AddressThis section describes

Strona 16 - PA Network Connections

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 23Installation Chapter 1Set the EtherNet/IP AddressThe linking device uses an RJ45 c

Strona 17 - Installation Chapter 1

24 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 1 InstallationEthernet Switch SettingsThis table describes the Ethernet sw

Strona 18 - Shielding

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 25Installation Chapter 1Software InstallationYou need the AOP for the Studio 5000 Lo

Strona 19 - PROFIBUS PA Physical

26 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 1 InstallationNotes:

Strona 20 - Cable Lengths

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 27Chapter 2Set Up in the Studio 5000 Logix Designer ApplicationAdd the 1788-EN2PAR L

Strona 21 - Termination Guidelines

28 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 2 Set Up in the Studio 5000 Logix Designer ApplicationAdd the 1788-CN2PAR

Strona 22 - Network Address

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 29Set Up in the Studio 5000 Logix Designer Application Chapter 2Configure the Linkin

Strona 23 - Set the EtherNet/IP Address

Rockwell Automation Publication XXXX-X.X.X - Month Year 3Table of ContentsImportant User Information . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 24 - ControlNet Switch Settings

30 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 2 Set Up in the Studio 5000 Logix Designer ApplicationDownloadDownloads th

Strona 25 - Software Installation

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 31Set Up in the Studio 5000 Logix Designer Application Chapter 2Configure the PA Mas

Strona 26 - Chapter 1 Installation

32 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 2 Set Up in the Studio 5000 Logix Designer ApplicationConfigure the Field

Strona 27 - Logix Designer Application

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 33Set Up in the Studio 5000 Logix Designer Application Chapter 2Configure PV with Mu

Strona 28 - Add the 1788-CN2PAR

34 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 2 Set Up in the Studio 5000 Logix Designer ApplicationValve Positioner Con

Strona 29 - Configure the Linking Device

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 35Set Up in the Studio 5000 Logix Designer Application Chapter 24. Configure the inp

Strona 30

36 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 2 Set Up in the Studio 5000 Logix Designer ApplicationPROFIBUS PA Redundan

Strona 31 - Configure the PA Master

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 37Set Up in the Studio 5000 Logix Designer Application Chapter 2LimitationsThe linki

Strona 32 - Configure the Field Devices

38 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 2 Set Up in the Studio 5000 Logix Designer ApplicationMaster and media red

Strona 33

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 39Set Up in the Studio 5000 Logix Designer Application Chapter 2SoftwareMedia Redund

Strona 34 - Configuration

4 Rockwell Automation Publication XXXX-X.X.X - Month YearTable of ContentsConfigure PV with Multiple Formats . . . . . . . . . . . . . . . . . . . .

Strona 35

40 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 2 Set Up in the Studio 5000 Logix Designer ApplicationA short on either bu

Strona 36 - PROFIBUS PA Redundancy

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 41Set Up in the Studio 5000 Logix Designer Application Chapter 2MultiMaster ModeWhen

Strona 37 - Master Redundancy

42 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 2 Set Up in the Studio 5000 Logix Designer ApplicationMaster Config Mismat

Strona 38

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 43Set Up in the Studio 5000 Logix Designer Application Chapter 2Redundant PA Code Ex

Strona 39 - Software

44 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 2 Set Up in the Studio 5000 Logix Designer ApplicationNotes:

Strona 40

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 45Chapter 3Logix AssembliesPA Master Input ImageEach linking device uses a total of

Strona 41 - MultiMaster Mode

46 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 3 Logix AssembliesModuleStatusThis word is currently reserved.Connection S

Strona 42 - Master Node Mismatch

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 47Logix Assemblies Chapter 3ParameterFaultThis bit is set if there is a fault in the

Strona 43 - Redundant PA Code Example

48 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 3 Logix AssembliesField Device Output ImageEach field device displays its

Strona 44

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 49Chapter 4DiagnosticsLinking Device is OfflineUse these diagnostic checks to help y

Strona 45 - Logix Assemblies

Rockwell Automation Publication XXXX-X.X.X - Month Year 5Table of ContentsGlossaryIndex

Strona 46 - Field Device Input Image

50 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 4 DiagnosticsField Device is Not DetectedUse these diagnostic checks to he

Strona 47 - Logix Assemblies Chapter 3

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 51Diagnostics Chapter 4The linking device AOP scan reports NO DEVICES FOUND when lin

Strona 48 - Field Device Output Image

52 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 4 DiagnosticsField Device is Not ConfiguredUse these diagnostic checks to

Strona 49 - Diagnostics

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 53Diagnostics Chapter 4The field device indicates red in the AOP.The field device in

Strona 50 - Field Device is Not Detected

54 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 4 DiagnosticsWeb InterfaceTo view device status and diagnostic information

Strona 51

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 55Diagnostics Chapter 41. Click Advanced in the config tree.2. Choose the DTM revisi

Strona 52 - Field Device Faults

56 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Chapter 4 DiagnosticsNotes:

Strona 53

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 57Appendix ALinking Device Display StatusThe display of the linking device provides

Strona 54 - Device Type Manager

58 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Appendix A Linking Device Display StatusThe lower portion of the main page shows t

Strona 55 - Diagnostics Chapter 4

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 59Linking Device Display Status Appendix AField Device PageThe next 23 Field Device

Strona 56 - Chapter 4 Diagnostics

6 Rockwell Automation Publication XXXX-X.X.X - Month YearTable of Contents

Strona 57 - Linking Device Display Status

60 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Appendix A Linking Device Display StatusNotes:

Strona 58 - PA Master Page

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 61Appendix BPA TopologyMaster Mode 0Single MasterA Bus OnlyTe r m i na te d a t t h

Strona 59 - Field Device Page

62 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Appendix B PA TopologyMaster Mode 3Single MasterB Bus OnlyNot terminated at the li

Strona 60

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 63PA Topology Appendix BMaster Mode 7Single MasterSplit BusNot terminated at the lin

Strona 61 - PA Topology

64 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Appendix B PA TopologyMaster Mode 11MultiMasterA Bus OnlyNot terminated at the lin

Strona 62 - Master Mode 6

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 65PA Topology Appendix BMaster Mode 15MultiMasterDual BusTe r m i na te d at t h e

Strona 63 - Master Mode 10

66 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014Appendix B PA TopologyNotes:

Strona 64 - Master Mode 14

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 67GlossaryThe following terms and abbreviations are used throughout this manual. For

Strona 65 - Master Mode 16

68 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014GlossaryDO Abbreviation for discrete output; signal is generated by the host syste

Strona 66 - Appendix B PA Topology

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 69Glossaryring bus A network where signals are transmitted from one station and repl

Strona 67

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 7PrefaceIntroductionThis user manual describes the installation and operation of the

Strona 68

70 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014GlossaryNotes:

Strona 69

Rockwell Automation Publication XXXX-X.X.X - Month Year 71IndexNumerics1788-PARJB junction box 36, 37, 38, 40AAOPversion 25auto-terminate function, ju

Strona 70

72 Rockwell Automation Publication XXXX-X.X.X - Month YearIndexMmain page displayCNet MAC 57IP 57not owned 57PA bus A/B 57status descriptionsbus A tri

Strona 71

Rockwell Automation Publication XXXX-X.X.X - Month Year 73IndexTtermination locations 21, 61terminator impedance 21Vvalve positioner 34

Strona 72

74 Rockwell Automation Publication XXXX-X.X.X - Month YearIndexNotes:

Strona 74

Publication 1788-UM058B-EN-P - September 2014Supersedes Publication 1788-UM058A-EN-P - October 2012 Copyright © 2014 Rockwell Automation, Inc. All rig

Strona 75

8 Rockwell Automation Publication 1788-UM058B-EN-P - September 2014PrefaceNetwork Diagrams1788-EN2PAR Linking Device and EtherNet/IP NetworkThis diagr

Strona 76 - Documentation Feedback

Rockwell Automation Publication 1788-UM058B-EN-P - September 2014 9Preface1788-CN2PAR Linking Device and ControlNet NetworkThe diagram shows an exampl

Komentarze do niniejszej Instrukcji

Brak uwag