6 FLEX Integra 4 Input Analog Module
Publication 1793-5.4 - June 1999
Indicators
$ 3RZHULQGLFDWRULQGLFDWHVSRZHUDSSOLHGWRPRGXOH
% ,QVHUWDEOHODEHOIRUZULWLQJLQGLYLGXDORXWSXWGHVLJQDWLRQV
Input Map
Output Map
Bit/
Word
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Read
0 S Analog Input Value for Channel 0
1 S Analog Input Value for Channel 1
2 S Analog Input Value for Channel 2
3 S Analog Input Value for Channel 3
4-7 Reserved
8 PU U3U2U1U0
Where: S = Sign bit
PU = Power up bit
U = Underrange bit
Bit/
Word
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Write
0 Reserved C3C2C1C0Reserved F3F2F1 F0
Where: F = Full Range bit
C = Configure Select bit