FLEX I/O and FLEX Integra are trademarks
of Rockwell Automation Publication 1793-5.11 - December 1999
Installation Instructions
FLEX Integra
16 Protected Sink Output Module
(Cat. No. 1793-OV16P and -OV16PS)
Module Installation
This module mounts on a DIN rail. It connects to an adapter or another
FLEX I/O or FLEX Integra module. Note: If using this module with FLEX
I/O modules, do not mount between FLEX I/O modules. Mount Integra
modules to the right of FLEX I/O modules. To mount this module:
1. Remove the cover plug (if used) in the male connector of the unit to
which you are connecting this module.
2. Position the module on the 35 x 7.5mm DIN rail A (A-B pt. no.
199-DR1).
3. Rotate the module onto the DIN rail with the top of the rail hooked
under the lip on the rear of the module.
30869-M
A
A
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - FLEX Integra

FLEX I/O and FLEX Integra are trademarks of Rockwell Automation Publication 1793-5.11 - December 1999Installation InstructionsFLEX Integra 16 Protect

Strona 2

2 FLEX Integra 16 Protected Sink Output Module Publication 1793-5.11 - December 19994. Press down to lock the module on the DIN rail.lIf the module do

Strona 3 - Low Voltage Directive

FLEX Integra 16 Protected Sink Output Module 3 Publication 1793-5.11 - December 1999European Union Directive ComplianceIf this p

Strona 4 - 01 2345678 9101112131415COM

4 FLEX Integra 16 Protected Sink Output Module Publication 1793-5.11 - December 1999WiringThis module is available with 2 styles of connectors; screw-

Strona 5 - Memory Mapping

FLEX Integra 16 Protected Sink Output Module 5 Publication 1793-5.11 - December 1999Wiring ConnectionsIndicatorsA = Status indic

Strona 6

6 FLEX Integra 16 Protected Sink Output Module Publication 1793-5.11 - December 1999C-UL and UL Hazardous Location ApprovalApprobation d’utilisation d

Strona 7

FLEX Integra 16 Protected Sink Output Module 7 Publication 1793-5.11 - December 1999C-UL and UL Hazardous Location ApprovalAppro

Strona 8

Publication 1793-5.11 - December 1999 PN957259-18Supersedes publication 1793-5.11 - September 1999 © (1999) Rockwell International Corporation.Printed