User Manual
Bulletin 193 E1 Plus EtherNet/IP Side Mount Module
Catalog Number
193-ETN
Przeglądanie stron 0
1 2 3 4 5 6 ... 97 98

Podsumowanie treści

Strona 1 - User Manual

User ManualBulletin 193 E1 Plus EtherNet/IP Side Mount ModuleCatalog Number 193-ETN

Strona 2 - Important User Information

10 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 1 Wiring Figure 5 - Wiring DiagramTable 1 - Wire and Size Torque Specifi

Strona 3

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 11 Chapter 1DimensionsFigure 6 - Dimension DiagramNetwork DesignThe E1 Plus EtherNe

Strona 4 - EtherNet/IP Information

12 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 1 Rockwell Automation offers a line of Allen-Bradley managed and unmanage

Strona 5

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 13Chapter 2Protection FunctionsIntroductionThe purpose of this chapter is to provide detai

Strona 6

14 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 2 Parameter 13, Wa r n i n g E n a b l e , allows the installer to enabl

Strona 7 - Installation and Wiring

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 15 Chapter 2Jam ProtectionMotor current greater than the motor's nameplate rat

Strona 8 - Features

16 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 2 Jam WarningParameter 21, Jam Warn Level, allows the installer to define

Strona 9 - Installation

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 17 Chapter 2When the Underload Warning conditions are satisfied, the following will

Strona 10 - Figure 5 - Wiring Diagram

18 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 2 • No warning currently exists• Comm Idle Warning is enabled• The networ

Strona 11 - Network Design

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 19Chapter 3Configure an E1 Plus EtherNet/IP Module To Operate on the NetworkIntroductionTh

Strona 12 - Chapter 1

Important User InformationSolid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Strona 13 - Protection Functions

20 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 3 Check with your Ethernet network administrator to determine if you need

Strona 14 - Protection

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 21 Chapter 35. Double-click the MAC address of the module to be configured.The MAC

Strona 15 - Jam Protection

22 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 3 Assign Network Parameters Via a Web Browser and MAC Scanner SoftwareIn

Strona 16 - Underload Protection

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 23 Chapter 37. Open a web browser and type the IP address on the address line to vi

Strona 17 - Communication Idle

24 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 3 10. Assign the appropriate network settings per the recommendation of t

Strona 18 - IMPORTANT

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 25 Chapter 3module. You might have to disconnect from the uplink to set the address

Strona 19 - Operate on the Network

26 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 3 DNS AddressingTo further qualify a module’s address, use DNS addressing

Strona 20 - DHCP Utility

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 27 Chapter 31. Type the IP address of the E1 Plus EtherNet/IP Side Mount Module on

Strona 21 - Chapter 3

28 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 3 2. Select the network type as EtherNet/IP and select Search.3. Locate t

Strona 22 - Software

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 29 Chapter 33. Register a single file, browse to the location where the EDS file is

Strona 23

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 3Table of ContentsInstallation and WiringIntroduction . . . . . . . . . . . . . . . . . .

Strona 24 - Parameters

30 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 3 5. Accept the Graphic Image by selecting Next.6. Select Next to registe

Strona 25 - Detection

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 31 Chapter 37. Select Finish to successfully register the module.

Strona 26 - Install EDS File

32 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 3

Strona 27

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 33Chapter 4Automation Controller and Software CommunicationsIntroductionThe E1 Plus EtherN

Strona 28 - Register the EDS File

34 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 1. Select the controller type, chassis type, slot number, and project p

Strona 29

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 35 Chapter 43. Select the desired EtherNet/IP scanner module and click OK.4. Enter

Strona 30 - Chapter 3

36 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 2. Right-click on the Ethernet/IP scanner in I/O Configuration and sele

Strona 31

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 37 Chapter 45. Enter the IP address of the E1 Plus EtherNet/IP Side Mount Module.6.

Strona 32

38 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 1. Open the Controller Tags window.2. Select the Monitor Tags tab.Three

Strona 33 - Communications

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 39 Chapter 41. Select the controller type, chassis type, slot number, and project p

Strona 34 - Select Module Type window

4 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Accessing Generic Module Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 35 - Chapter 4

40 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 3. Select the desired EtherNet/IP scanner module and click OK.4. Enter

Strona 36 - Chapter 4

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 41 Chapter 42. Right-click on the Ethernet/IP scanner in I/O Configuration and sele

Strona 37

42 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 6. Set the Connection Parameters. I/O data is accessed using Input Inst

Strona 38

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 43 Chapter 4Downloading the Generic Configuration to the PLC1. In the RSLogix 5000

Strona 39

44 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 4. In the Connected To Go Online window, click Download.5. In the Downl

Strona 40

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 45 Chapter 42. Open the Controller Tags window.3. Select the Monitor Tags tab.Three

Strona 41

46 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 1. Configure the configuration tab for the message instruction with the

Strona 42

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 47 Chapter 4Users can read all of the motor diagnostic data back in one MSG instruc

Strona 43

48 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 MicroLogix 1100 and 1400 Explicit MessagingMicroLogix 1100 and 1400 con

Strona 44 - Accessing Generic Module Data

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 49 Chapter 4• Class: 4 – the Assembly Object• Instance: 111 – the Complete Motor St

Strona 45 - Logix Explicit Messaging

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 5Control Supervisor Object — CLASS CODE 0x29 . . . . . . . . . . . . . 89Overload Object

Strona 46

50 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 1. Write the appropriate ladder logic to execute a MSG instruction for

Strona 47

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 51 Chapter 43. Configure the MultiHop tab in the MSG instruction with the following

Strona 48 - Explicit Messaging

52 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 1. Configure an OPC topic within RSLinx Classic to communicate to the E

Strona 49

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 53 Chapter 43. Start FactoryTalk View Studio and create a new application. Draw a n

Strona 50

54 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4 6. Expand the OPC topic name that you created in RSLinx Classic, select

Strona 51 - Predefined Tags

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 55 Chapter 48. Test the display by pressing the Test Run button to view data dire

Strona 52

56 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 4

Strona 53

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 57Chapter 5Email NotificationsIntroductionThis chapter describes email notifications and h

Strona 54

58 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 5 The first word in the subject is the Device Name. If a Device Name is n

Strona 55

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 59 Chapter 54. Enter the information into the email notification fields as describe

Strona 56

6 Rockwell Automation Publication 193-UM012B-EN-P - June 2011

Strona 57

60 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 5 1. In a web browser, enter the IP address of the E1 Plus EtherNet/IP mo

Strona 58 - Email Configuration

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 61 Chapter 54. Enter the Device Identity information into the fields as described b

Strona 59 - Configure Device Identity

62 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 5

Strona 60 - Chapter 5

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 63Chapter 6Device Parameters and TagsIntroductionThe E1 Plus EtherNet/IP Side Mount Module

Strona 61 - Limitations

64 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 6 Parameter Group ListingThe E1 Plus EtherNet/IP Module contains five par

Strona 62

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 65 Chapter 6Advanced Setup GroupTrip Status Parameter No. 3This parameter provides

Strona 63

66 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 6 Warning Enable Parameter No.13This parameter allows the installer to en

Strona 64 - Monitor Group

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 67 Chapter 6Jam Inhibit Time Parameter No. 18This parameter defines the amount of t

Strona 65 - Advanced Setup Group

68 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 6 Reset/Lock GroupUL Inhibit Time Parameter No. 22This parameter defines

Strona 66

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 69 Chapter 6I/O Setup GroupSet To Defaults Parameter No. 25This parameter allows th

Strona 67

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 7Chapter 1Installation and WiringIntroductionThe purpose of this chapter is to provide the

Strona 68 - Reset/Lock Group

70 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 6 OutA En FltValue Parameter No. 37This parameter determines the state th

Strona 69 - I/O Setup Group

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 71 Chapter 6Trip History GroupIN2 Assignment Parameter No. 41This parameter allows

Strona 70

72 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 6 Trip Log 3 Parameter No. 8This parameter records the trip previous to T

Strona 71 - Trip History Group

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 73Chapter 7TroubleshootingIntroductionThe purpose of this chapter is to assist in troubles

Strona 72

74 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 7 1. The MODULE STATUS LED should flash green for approximately 1/4 secon

Strona 73

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 75 Chapter 7Unrecoverable Error ModeIn Unrecoverable Error Mode, the E1 Plus EtherN

Strona 74 - Recoverable Error Mode

76 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 7 Table 8 - Input and Output Troubleshooting Procedures Failure Type Fail

Strona 75 - Unrecoverable Error Mode

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 77Appendix ASpecificationsSpecificationsTerminal Ratings:Terminal Screw M3Wire Cross Secti

Strona 76

78 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Appendix A Terminals IN 1: IN 2: SSV (Sensor Supply Voltage)

Strona 77

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 79 Appendix AWARNING: This is a class A product. In domestic environment, this prod

Strona 78

8 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Chapter 1 FeaturesFigure 1 - FeaturesATTENTION: To remain compliant with UL/CSA Ce

Strona 79

80 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Appendix A

Strona 80 - Appendix A

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 81Appendix BEtherNet/IP InformationElectronic Data SheetsElectronic Data Sheet (EDS) files

Strona 81

82 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Appendix B Identity Object instances contain the following instance attributes:Th

Strona 82

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 83 Appendix BAssembly Object — CLASS CODE 0x04The following class attributes are su

Strona 83 - Output Assemblies

84 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Appendix B Input AssembliesTable 18 - Instance 50 — Trip Status Input Assembly fr

Strona 84 - Input Assemblies

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 85 Appendix BThe following services are implemented for the Assembly Object:Connect

Strona 85

86 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Appendix B Two instances of the Discrete Input Point Object are supported as foll

Strona 86

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 87 Appendix BThe following common services are implemented for the Discrete Output

Strona 87

88 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Appendix B The following commons services are implemented for the Parameter Objec

Strona 88 - Link UINT 0

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 89 Appendix BThe following instance attributes are supported for all parameter grou

Strona 89

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 9 Chapter 1InstallationFigure 2 - Installation [1]Figure 3 - Installation [2]Figure

Strona 90

90 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Appendix B The following common services are implemented for the Control Supervis

Strona 91 - PCP Object — CLASS CODE 0xC2

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 91 Appendix BOverload Object — CLASS CODE 0x2CNo class attributes are supported for

Strona 92

92 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Appendix B The following instance attributes are implemented for all parameter at

Strona 93

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 93 Appendix BThe following common services are implemented for the TCP/IP Interface

Strona 94

94 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Appendix B The following instance attributes are implemented for all parameter at

Strona 95 - Rockwell Automation

Rockwell Automation Publication 193-UM012B-EN-P - June 2011 95 Appendix BThe following common services are implemented for the Ethernet Link Ob

Strona 96 - Appendix B

96 Rockwell Automation Publication 193-UM012B-EN-P - June 2011Appendix B

Strona 98 - Documentation Feedback

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400Rockwell Automation Publication 19

Komentarze do niniejszej Instrukcji