Rockwell-automation 20P PowerFlex DC Drive - Frame A Pulse Transformer Instrukcja Użytkownika Strona 2

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 20
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 1
2 PowerFlex® DC Drive - Frame A Pulse Transformer Circuit Board
What You Need to Do
To install the Pulse Transformer board:
Step 1: Remove power from the drive
Step 2: Remove the protective covers
Step 3: Remove the Control EMI shield and Control board
Step 4: Remove the Pulse Transformer and Switching Power Supply
boards
Step 5: Configure the new Pulse Transformer board
Step 6: Install the new Pulse Transformer board and existing
Switching Power Supply board
Step 7: Install the Control EMI Shield and Control board
Step 8: Replace the protective covers and document the change
Step 1: Remove Power
from the Drive
1. Remove and lock-out all incoming power to the drive.
ATTENTION: Remove power before making or breaking cable
connections. When you remove or insert a cable connector with
power applied, an electrical arc may occur. An electrical arc can
cause personal injury or property damage by:
sending an erroneous signal to your system’s field devices,
causing unintended machine motion
causing an explosion in a hazardous environment
Electrical arcing causes excessive wear to contacts on both the
module and its mating connector. Worn contacts may create
electrical resistance.
L1 L2 L3
O
I