Rockwell-automation 20P PowerFlex DC Drive - Frame C Field SCR Module Instrukcja Użytkownika Strona 2

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 10
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 1
2 PowerFlex® DC Drive - Frame C Field SCR Module
What You Need to Do
The Field SCR module is located below the Field Snubber circuit board in
the upper left corner of the drive chassis, next to the Pulse Transformer
circuit board.
To install the Field SCR module:
Step 1: Remove power from the drive
Step 2: Remove the protective covers
Step 3: Move the EMI Shield and Control board
Step 4: Remove the Field Snubber board and existing Field SCR
module
Step 5: Install the Field Snubber board and new Field SCR module
Step 6: Install the EMI Shield and Control board
Step 7: Replace the protective covers and document the change
Field SCR module
below Field Snubber
board
Control EMI shield
and Control board
Note: Drive shown with
front covers removed.
Pulse Transformer
board
Przeglądanie stron 1
1 2 3 4 5 6 7 8 9 10

Komentarze do niniejszej Instrukcji

Brak uwag