2 Rockwell Automation Publication 20P-IN010C-EN-P - February 2012
PowerFlex DC Drive Frame C Pulse Transformer Circuit Board
What You Need to Do
To install the Pulse Transformer board:
❐ Step 1: Remove power from the drive
❐ Step 2: Remove the protective covers
❐ Step 3: Remove the existing Pulse Transformer board
❐ Step 4: Configure the new Pulse Transformer board
❐ Step 5: Install the new Pulse Transformer board
❐ Step 6: Replace the protective covers and document the change
Step 1: Remove Power from
the Drive
1. Remove and lock-out all incoming power to the drive.
ATTENTION: Remove power before making or breaking cable connections.
When you remove or insert a cable connector with power applied, an electrical
arc may occur. An electrical arc can cause personal injury or property damage by:
• sending an erroneous signal to your system’s field devices, causing unintended
machine motion
• causing an explosion in a hazardous environment
Electrical arcing causes excessive wear to contacts on both the module and its
mating connector. Worn contacts may create electrical resistance.