Rockwell-automation 20P PowerFlex DC Drive - Frame C Switching Power S Instrukcja Użytkownika Strona 6

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 8
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 5
6 PowerFlex® DC Drive - Frame C Switching Power Supply Circuit Board
3. Disconnect the cable from connector XSW on the Switching Power
Supply board (see Figure 1 on page 5
for location) and lower the
Control EMI shield until it rests on the drive chassis.
Important: If the drive is not in a vertical position, the Control EMI
shield will not stay open without a means of restraint.
4. Disconnect the cables from connector XA and XUV on the Switching
Power Supply board (see Figure 1 on page 5
for location).
5. If present, disconnect the jumper from terminals SA-SB (see Figure
1 on page 5 for location).
Important: Be sure to replace the jumper between terminals SA-SB if
using 115V AC control input power when installing a new
Switching Power Supply board.
Remove cable
Disconnect cables and wiring
Przeglądanie stron 5
1 2 3 4 5 6 7 8

Komentarze do niniejszej Instrukcji

Brak uwag