Rockwell-automation 25-COMM-D PowerFlex 525 DeviceNet Adapter Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation 25-COMM-D PowerFlex 525 DeviceNet Adapter. Rockwell Automation 25-COMM-D PowerFlex 525 DeviceNet Adapter User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User Manual

PowerFlex 525 DeviceNet AdapterCatalog Number: 25-COMM-DUser Manual

Strona 2 - Important User Information

10 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 1 Getting StartedFeaturesThe features of the DeviceNet adapter include:• Mou

Strona 3 - Table of Contents

100 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsAssembly ObjectClass CodeServicesInstancesClass Attribu

Strona 4

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 101DeviceNet Objects Appendix CConnection ObjectClass CodeServicesInstancesInstance At

Strona 5 - PowerFlex 525 Drives

102 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet Objects14 Get Produced Connection PathArray of UINT Byte strea

Strona 6

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 103DeviceNet Objects Appendix CRegister ObjectClass CodeServicesInstances (Single-Driv

Strona 7 - Overview

104 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsInstances (Multi-Drive)36 Logic Status (read-only)37 Re

Strona 8 - Preface Overview

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 105DeviceNet Objects Appendix CClass AttributesInstance Attributes Attribute ID Access

Strona 9 - Getting Started

106 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsParameter ObjectClass CodeServicesInstances (Single-Dri

Strona 10 - Understanding Parameter

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 107DeviceNet Objects Appendix CClass AttributesInstance AttributesAttribute ID Access

Strona 11 - Required Equipment

108 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet Objects12 Get Default Value(1) (3)13 Get Scaling MultiplierUIN

Strona 12 - Safety Precautions

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 109DeviceNet Objects Appendix CParameter Group ObjectClass CodeServicesInstancesClass

Strona 13 - Quick Start

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 11Getting Started Chapter 1Yo u c an vi e w ad ap te r Device parameters and Host pa

Strona 14 - Chapter 1 Getting Started

110 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsInstance AttributesAttribute ID Access Rule Name Data T

Strona 15 - Installing the Adapter

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 111DeviceNet Objects Appendix CPCCC ObjectClass CodeServicesInstancesSupports Instance

Strona 16

112 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsMessage Structure for Execute_Local_PCCCThe DeviceNet a

Strona 17 - Connecting the Adapter to

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 113DeviceNet Objects Appendix CN-Files (Multi-Drive)N-File DescriptionN44 This N-file

Strona 18

114 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsDPI Device ObjectClass CodeServicesInstancesThe number

Strona 19

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 115DeviceNet Objects Appendix C3 Get Product Series USINT 1 = A2 = B …4 Get Number of

Strona 20 - Applying Power

116 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsInstance AttributeAttribute ID Access Rule Name Data Ty

Strona 21 - EtherNet/IP

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 117DeviceNet Objects Appendix CDPI Parameter ObjectClass CodeInstancesThe number of in

Strona 22

118 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsInstance AttributeAttribute ID Access Rule Name Data Ty

Strona 23 - Configuring the Adapter

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 119DeviceNet Objects Appendix C20 Get International DSI Online Read Full Struct of:BOO

Strona 24

12 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 1 Getting StartedSafety PrecautionsPlease read the following safety precauti

Strona 25 - Setting the Node Address

120 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsDescriptor AttributesBit Name Description0 Data Type (B

Strona 26 - (Optional)

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 121DeviceNet Objects Appendix CExtended Descriptor AttributesBit Name Description0 Ind

Strona 27

122 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsFormulas for ConvertingDisplay Value = ((Internal Value

Strona 28 - Polled I/O

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 123DeviceNet Objects Appendix CDPI Fault ObjectClass CodeProducts such as PowerFlex dr

Strona 29 - Setting a Fault Action

124 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsInstance AttributesAttribute ID Access Rule Name Data T

Strona 30 - Defaults

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 125DeviceNet Objects Appendix CDPI Diagnostic ObjectClass CodeServicesInstancesThe num

Strona 31 - Firmware

126 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsInstance AttributeAttribute ID Access Rule Name Data Ty

Strona 32

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 127Appendix DLogic Command/Status Words: PowerFlex 525 DrivesAppendix D presents the d

Strona 33 - Configuring the I/O

128 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Appendix D Logic Command/Status Words: PowerFlex 525 DrivesPosition Bit Definitions

Strona 34 - CompactLogix Example

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 129Logic Command/Status Words: PowerFlex 525 Drives Appendix DPosition Bit Definitions

Strona 35 - Configuring the I/O Chapter 4

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 13Getting Started Chapter 1Quick StartThis section is provided to help experienced use

Strona 36 - Chapter 4 Configuring the I/O

130 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Appendix D Logic Command/Status Words: PowerFlex 525 DrivesNotes:

Strona 37

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 131GlossaryThe following terms and abbreviations are used throughout this manual.For d

Strona 38

132 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013GlossaryConnected Components WorkbenchSoftwareThe recommended tool for monitoring a

Strona 39

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 133 GlossaryDatalinks A Datalink is a type of pointer used by PowerFlex 525 drives to

Strona 40

134 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013GlossaryFaulted Node Recovery This DeviceNet feature lets you change a configuratio

Strona 41

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 135 GlossaryNode Address A DeviceNet network can have as many as 64 devices connected

Strona 42

136 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013GlossaryRSNetWorx for DeviceNet Software A software tool for configuring and monito

Strona 43

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 137IndexAadapteradding to the scan list, 42applying power, 20commissioning, 15componen

Strona 44

138 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Indexsetting the fault action, 29II/Oabout, 47calculating I/O byte sizes, 43configu

Strona 46

14 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 1 Getting StartedNotes:

Strona 47 - Using the I/O

Publication 520COM-UM002A-EN-E - April 2013Copyright © 2013 Rockwell Automation, Inc. All rights reserved.Rockwell Automation SupportRockwell Automati

Strona 48 - Using Reference/Feedback

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 15Chapter 2Installing the AdapterChapter 2 provides instructions for installing the De

Strona 49 - Using Datalinks

16 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 2 Installing the AdapterSetting the Node Address and Data Rate Using the DIP

Strona 50 - Example Ladder Logic

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 17Installing the Adapter Chapter 2Data Rate Switch Settings (UP = ON = 1) Setting Sing

Strona 51

18 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 2 Installing the Adapterb. Press down and slide out the top cover of the con

Strona 52 - Program Tags

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 19Installing the Adapter Chapter 25. Align the Communication card-Drive header on the

Strona 53 - Example Datalink Data

Important User InformationSolid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Strona 54 - Chapter 5 Using the I/O

20 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 2 Installing the Adapter4. Connect the 5-pin linear plug to the DeviceNet ca

Strona 55 - Using Explicit Messaging

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 21Installing the Adapter Chapter 2the status indicators should be green after an initi

Strona 56 - CompactLogix Examples

22 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 2 Installing the Adapter2. Set the value of Host parameter P047 [Speed Refer

Strona 57

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 23Chapter 3Configuring the AdapterChapter 3 provides instructions and information for

Strona 58 - PowerFlex 525 drive

24 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 3 Configuring the AdapterStep Key(s) Example Display1. When power is applied

Strona 59

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 25Configuring the Adapter Chapter 3Using the PowerFlex 4-Class HIM to Access Parameter

Strona 60 - Write Multiple Messaging

26 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 3 Configuring the Adapter2. Reset the adapter by power cycling the drive.Set

Strona 61

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 27Configuring the Adapter Chapter 3Configuring a Master-Slave HierarchyThe controller

Strona 62

28 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 3 Configuring the Adapterperipheral send values to the network. To configure

Strona 63

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 29Configuring the Adapter Chapter 3Setting a Fault ActionBy default, when communicatio

Strona 64

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 3Table of ContentsImportant User Information . . . . . . . . . . . . . . . . . . . . .

Strona 65 - Parameters

30 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 3 Configuring the AdapterResetting the AdapterChanges to switch settings on

Strona 66 - IMPORTANT

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 31Configuring the Adapter Chapter 3Viewing the Adapter Status Using ParametersThe foll

Strona 67

32 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 3 Configuring the AdapterTo obtain a firmware update for this adapter, go to

Strona 68

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 33Chapter 4Configuring the I/OThis chapter provides instructions on how to configure a

Strona 69 - Using Multi-Drive Mode

34 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 4 Configuring the I/O6. Verify that your computer recognizes the drive. Sele

Strona 70

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 35Configuring the I/O Chapter 41. Start RSLogix 5000/Logix Designer. The application w

Strona 71 - System Wiring

36 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 4 Configuring the I/OAdding the Scanner to the I/O ConfigurationTo establish

Strona 72

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 37Configuring the I/O Chapter 47. Edit the following:8. Click OK. The Module Propertie

Strona 73 - Program Example

38 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 4 Configuring the I/OUsing RSNetWorx for DeviceNet Software to Configure and

Strona 74 - Generic Profile

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 39Configuring the I/O Chapter 4As the selected DeviceNet path is browsed, RSNetWorx fo

Strona 75 - Main Routine

4 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Table of ContentsUnderstanding the I/O Image. . . . . . . . . . . . . . . . . . . . .

Strona 76

40 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 4 Configuring the I/O6. Click Next.7. Check the Polled box.8. Enter “4” into

Strona 77 - Drive 0 Control Routine

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 41Configuring the I/O Chapter 49. In the graph view window, right-click the 1769-SDN i

Strona 78 - Drive 1 Control Routine

42 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 4 Configuring the I/O14. Click the Scanlist tab to begin the drive I/O confi

Strona 79 - Drive 2 Control Routine

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 43Configuring the I/O Chapter 4b. Enter the number of bytes that are required for your

Strona 80 - Drive 3 Control Routine

44 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 4 Configuring the I/OIf a Scanner Configuration dialog box appears, click Ye

Strona 81 - Drive 4 Control Routine

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 45Configuring the I/O Chapter 4If the Scanner Configuration dialog box appears asking

Strona 82 - Multi-Drive Mode Explicit

46 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 4 Configuring the I/O1. From the Communications menu in the RSLogix 5000/Log

Strona 83 - Additional Information

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 47Chapter 5Using the I/OThis chapter provides information and examples that explain ho

Strona 84

48 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 5 Using the I/OUnderstanding the I/O ImageThe terms input and output are def

Strona 85 - Troubleshooting

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 49Using the I/O Chapter 5When using a CompactLogix/ControlLogix controller, the 16-bit

Strona 86 - MOD Status Indicator

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 5Table of ContentsConnection Object. . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 87 - Viewing Adapter Diagnostic

50 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 5 Using the I/O– Host parameters C165...C168 [Opt Data Out 1...4]• When an I

Strona 88 - Viewing and Clearing Events

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 51Using the I/O Chapter 5CompactLogix ExampleCreating Ladder Logic Using the Logix Des

Strona 89 - Adapter Events

52 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 5 Using the I/OProgram TagsIn our example program, we will create 16-bit INT

Strona 90

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 53Using the I/O Chapter 5Compact Logix Example Ladder Logic Program Using a Drive Gene

Strona 91 - Specifications

54 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 5 Using the I/OCompactLogix Controller Example Datalinks for Ladder Logic Pr

Strona 92 - Appendix A Specifications

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 55Chapter 6Using Explicit MessagingThis chapter provides information and examples that

Strona 93 - Adapter Parameters

56 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 6 Using Explicit MessagingPerforming Explicit MessagingThere are five basic

Strona 94

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 57Using Explicit Messaging Chapter 6CompactLogix Example Ladder Logic Program to Read

Strona 95

58 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 6 Using Explicit MessagingCompactLogix Example Ladder Logic Program to Write

Strona 96

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 59Using Explicit Messaging Chapter 6CompactLogix – Formatting a Message to Write a Sin

Strona 97 - DeviceNet Objects

6 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Table of ContentsNotes:

Strona 98 - Identity Object

60 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 6 Using Explicit MessagingCompactLogix – Explanation of Request and Response

Strona 99

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 61Using Explicit Messaging Chapter 6Data Structures for Scattered Read MessagesRequest

Strona 100 - Assembly Object

62 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 6 Using Explicit MessagingData Structures for Scattered Write MessagesReques

Strona 101 - Connection Object

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 63Using Explicit Messaging Chapter 6CompactLogix Example Ladder Logic Program to Read

Strona 102

64 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 6 Using Explicit MessagingThe following table identifies the data that is re

Strona 103 - Register Object

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 65Using Explicit Messaging Chapter 6Example Scattered Read Request DataCompactLogix Ex

Strona 104 - Instances (Multi-Drive)

66 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 6 Using Explicit MessagingExample Controller Tags to Write Multiple Paramete

Strona 105 - Instance Attributes

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 67Using Explicit Messaging Chapter 6CompactLogix Example Scattered Write Request DataI

Strona 106 - Parameter Object

68 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 6 Using Explicit MessagingExample Scattered Write Response Data

Strona 107

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 69Chapter 7Using Multi-Drive ModeThis chapter provides information and a ControlLogix

Strona 108

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 7PrefaceOverviewRecommended DocumentationAll the recommended documentation listed in t

Strona 109 - Parameter Group Object

70 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 7 Using Multi-Drive ModeExample for Network on page 70). The first drive mus

Strona 110

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 71Using Multi-Drive Mode Chapter 7• Automatic Device Replacement (ADR) cannot be used

Strona 111 - PCCC Object

72 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 7 Using Multi-Drive ModeMulti-Drive Example of I/O ImageNote: If a daisy-cha

Strona 112 - N-Files (Single-Drive)

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 73Using Multi-Drive Mode Chapter 7The following Multi-drive parameters must be set in

Strona 113 - N-Files (Multi-Drive)

74 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 7 Using Multi-Drive Mode• Control the drives using various Logic Command bit

Strona 114 - DPI Device Object

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 75Using Multi-Drive Mode Chapter 7The following Tags are used for Drive 0:The same typ

Strona 115

76 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 7 Using Multi-Drive ModeMain RoutineDrive 0...4 Control RoutinesThe followin

Strona 116 - Instance Attribute

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 77Using Multi-Drive Mode Chapter 7Drive 0 Control Routine05(End)Copy FileSourceDestLen

Strona 117 - DPI Parameter Object

78 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 7 Using Multi-Drive ModeDrive 1 Control Routine05(End)Copy FileSourceDestLen

Strona 118

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 79Using Multi-Drive Mode Chapter 7Drive 2 Control Routine05(End)Copy FileSourceDestLen

Strona 119 - on page 122

8 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Preface Overview• RSLinx Classic (version 2.51), RSNetWorx for DeviceNet (version 2

Strona 120 - Descriptor Attributes

80 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 7 Using Multi-Drive ModeDrive 3 Control Routine05(End)Copy FileSourceDestLen

Strona 121

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 81Using Multi-Drive Mode Chapter 7Drive 4 Control Routine05(End)Copy FileSourceDestLen

Strona 122 - Object Specific Services

82 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 7 Using Multi-Drive ModeMulti-Drive Mode Explicit MessagingParameter address

Strona 123 - DPI Fault Object

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 83Using Multi-Drive Mode Chapter 7Parameter Read Message ConfigurationParameter Write

Strona 124

84 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 7 Using Multi-Drive Mode• If any of the daisy-chained drives (Drive 1 to Dri

Strona 125 - DPI Diagnostic Object

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 85Chapter 8TroubleshootingThis chapter provides information for diagnosing and trouble

Strona 126

86 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 8 TroubleshootingPORT Status IndicatorThis red/green bicolor LED indicates t

Strona 127 - Velocity Bit Definitions

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 87Troubleshooting Chapter 8NET A Status IndicatorThis red/green bicolor LED indicates

Strona 128 - Position Bit Definitions

88 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 8 TroubleshootingViewing and Clearing EventsThe adapter has an event queue t

Strona 129

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 89Troubleshooting Chapter 8The event queue can contain up to 32 entries, which are sto

Strona 130

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 9Chapter 1Getting StartedThe DeviceNet adapter is a communication option intended for

Strona 131 - Glossary

90 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Chapter 8 Troubleshooting45 Net IO Close An I/O connection from the network to the a

Strona 132

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 91Appendix ASpecificationsAppendix A presents the specifications for the adapter.Commu

Strona 133 - Glossary

92 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Appendix A SpecificationsNotes:

Strona 134

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 93Appendix BAdapter ParametersAppendix B provides information about the adapter parame

Strona 135

94 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Appendix B Adapter Parameters07 [Net Addr Cfg]Sets the network node address for the

Strona 136

Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013 95Adapter Parameters Appendix B15 [Comm Flt Action]Sets the action that the adapter an

Strona 137

96 Rockwell Automation Publication 520COM-UM002A-EN-E - April 2013Appendix B Adapter Parameters18 [Flt Cfg Ref]Sets the Reference data that is sent to

Strona 138

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 97Appendix CDeviceNet ObjectsAppendix C presents information about the DeviceNet objec

Strona 139

98 Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013Appendix C DeviceNet ObjectsIdentity ObjectClass CodeServicesInstances (Single-Drive

Strona 140 - Installation Assistance

Rockwell Automation Publication 520COM-UM001A-EN-E - April 2013 99DeviceNet Objects Appendix C7 Get Product Name SHORT_STRING Product name and rating9

Komentarze do niniejszej Instrukcji

Brak uwag