Chapter 6
The Transfer Menu
6–15
The PLC Address is the station number of the PLC-5 on the DH+ link to
which the DL40 is attached. This address must match the DIP switch settings
on the PLC.
The PLC Type is the type of Allen-Bradley PLC-5 on the DH+ link to which
the DL40 is attached. Use the PLC-5/250 choice for a PLC mounted in a
Pyramid Integrator chassis.
Selecting a Hardware Device
As shown below, you can select from a number of hardware devices for
performing PassThrough file transfers.
Figure 6.11
Hardware Device pop-up window
Your hardware device choices appear on a pop-up list.
Parameter Acceptable values
Hardware Device
1784-KL
1784-KT, KTX, PCMK
1770-KF2
1784-KT2
ETHERNET
DH+ Device
DH+ Device, Serial Interface
DH+ Device, Microchannel Bus