Rockwell-automation 2711 PANELBUILDER SOFTWARE USER MANUAL Instrukcja Użytkownika Strona 271

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 270
The Objects
Chapter 10
10-6
When two or more of these buttons are assigned to the same Button
Control address, they function like their hard-wired equivalents wired in
series: pressing either button, rather than both, turns off the PLC input bit.
IMPORTANT: The Momentary Normally Closed Push Button is not
retentive or presettable.
If the button is being pressed at the moment when a window (Information,
Alarm or Fault Window) pops up on the screen, its value is reset to 1.
ATTENTION: For Momentary Push Buttons (Normally Open
and Closed) the input bits remain in their last states and the
buttons’ input bits will not reset if a remote I/O fault occurs.
The rack fault bit should be monitored when using these
buttons.
Latched Push Button
The Latched Push Button uses a “handshake” bit (usually a PLC output bit)
as well as the button control and indicator bits.
Pressing the button will set the Button Control bit to 1. The PLC program
must set the handshake bit to 1 when the Button Control bit is set to 1.
When the handshake bit is set to 1, PanelView will reset the control bit to
0. Your PLC controller must be programmed to turn the handshake bit off
(to 0).
You can use a latched input push button if you have a PLC controller with
long program and I/O scan times. Use the handshake bit to signal that the
program has indeed read the PLC input bit. In theory you can accomplish
the same thing by establishing a long enough Push Button Input Hold
Time, but a Latched Input Push Button takes the guesswork out of
estimating the program or I/O scan times.
You could also use this push button if you want the control bit to remain on
until a particular process within the PLC controller is completed.
IMPORTANT: Operator screen changes are not permitted while the PLC
control bit is on. If the PLC controller initiates a screen change, the control
bit is reset to 0.
The Latched Push Button has two display states, 0 and 1. The push button
display state is controlled by the Indicator State Address. You can use this
feature to configure the button in a number of ways:
Przeglądanie stron 270
1 2 ... 266 267 268 269 270 271 272 273 274 275 276 ... 467 468

Komentarze do niniejszej Instrukcji

Brak uwag

ENERGY SISTEM Energy Tablet 7 Neo 2 manuales

Manuales del propietario y guías del usuario para Tabletas ENERGY SISTEM Energy Tablet 7 Neo 2.
Ofrecemos 1 manuales en pdf ENERGY SISTEM Energy Tablet 7 Neo 2 para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para Tabletas ENERGY SISTEM

Modelos Tipo de documento
422456 Manual de usuario     Energy Sistem 422456 tablet, 2 paginas
x7 Quad Manual de usuario      Energy Sistem x7 Quad 8GB 3G Black, Grey, 50 paginas
i504 Titanium Manual de usuario   Multimedia [de] [en] , 90 paginas
Energy s7 Manual de usuario ENERGY s7 Dual, 25 paginas
i504 Titanium Manual de usuario   Multimedia, 32 paginas
Energy i10 Manual de usuario ENERGY i10 Quad SuperHD, 24 paginas
i504 Titanium Manual de usuario    ENERGY SISTEM i504 Titanium User manual, 116 paginas
Energy s7 Manual de usuario      ENERGY SISTEM Energy s7 User manual, 44 paginas
Dark Iron i724 Manual de usuario   i724 Dark Iron - Energy Sistem, 47 paginas
Energy i10 Manual de usuario      ENERGY SISTEM Energy i10 User manual, 46 paginas
P4350 Manual de usuario   descargar - Energy Sistem, 28 paginas
Dark Iron i724 Manual de usuario   i724 Dark Iron - Energy Sistem [en] , 44 paginas
ENERGY i8 Manual de usuario      ENERGY SISTEM ENERGY i8 User manual, 46 paginas