Introduction This guide provides the basic information required to start up your
ArmorStart
®
Distributed Motor Controller. Factory default settings
and information regarding installing, programming, and DeviceNet™
Node Commissioning are described here. For detailed information on
specific product features or configurations, refer to the ArmorStart
user manual, publication 280G-UM001*.
This guide is intended for qualified service personnel responsible for
setting up and servicing these devices. You must have previous
experience with and a basic understanding of electrical terminology,
configuration procedures, required equipment, and safety precautions.
You should understand DeviceNet network operations, including how
slave devices operate on a network and communicate with a
DeviceNet master. You should also be familiar with RSNetWorx™
for DeviceNet. You must use RSNetWorx for DeviceNet Revision
3.21 Service Pack 2 or later. This software package is referred to
often in this manual. Rockwell Automation product EDS files are
available on the internet at: http://www.ab.com/networks/eds
.
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - MOTOR CONTROLLER

QUICK STARTARMORSTART® DISTRIBUTED MOTOR CONTROLLERGetting StartedBULLETIN 280G/281GIntroduction This guide provides the basic information required to

Strona 2 - 2

10 Publication 280G-QS001A-EN-P - December 2008Node Commissioning using HardwareThe ArmorStart is shipped with the hardware rotary switches set

Strona 3 - Specifications

Publication 280G-QS001A-EN-P - December 2008 11Using Automap feature with default Input and Output (I/O) assembliesThe Automap feature availabl

Strona 4 - Description

12 Publication 280G-QS001A-EN-P - December 2008Setting the Motor FLA and Overload Trip ClassThe product should now be configured and communicat

Strona 5

Publication 280G-QS001A-EN-P - December 2008 13Quick Reference TroubleshootingThere are four LEDs on the front of the ArmorStart that can provi

Strona 6 - Three-Phase Power Media

14 Publication 280G-QS001A-EN-P - December 2008Fault LED indications for Bulletin 280G and 281G ArmorStart Distributed Motor ControllersTable 8

Strona 7 - 7

Publication 280G-QS001A-EN-P - December 2008 15Bulletin 280G/281G ParametersTable 9 Starter Display and Parameter SettingsTable 10 FLA Setting

Strona 8 - 8

16 Publication 280G-QS001A-EN-P - December 2008Figure 8 Bulletin 280G/281G ArmorStart LED StatusIndicationMotorConnectionDeviceNetConnection(M

Strona 9 - 9

Publication 280G-QS001A-EN-P - December 2008 17Table 11 DeviceNet Media ➊ ➊See publication M116-CA001A-EN-P for complete cable selection inform

Strona 10 - Detail A

18 Publication 280G-QS001A-EN-P - December 2008Table 12 Sensor Media ➊ ➊See Publication M116-CA001A-EN-P for complete cable selection informati

Strona 11

Publication 280G-QS001A-EN-P - December 2008 19Notes:

Strona 12 - 12

2 Publication 280G-QS001A-EN-P - December 2008Installation The ArmorStart Distributed Motor Controller is convection cooled. Operating temperat

Strona 13 - Troubleshooting

Publication 280G-QS001A-EN-P — December 2008 PN-29248Copyright ©2008 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.Registerd Trademark

Strona 14 - Fault LED indications for

Publication 280G-QS001A-EN-P - December 2008 3Wiring Power, Control, Safety Monitor Inputs, and Ground Wiring Table 1 provides the power, contr

Strona 15 - Bulletin 280G/281G Parameters

4 Publication 280G-QS001A-EN-P - December 2008ArmorConnect Power Media DescriptionThe ArmorStart Power Media offers both three-phase and contro

Strona 16 - 16

Publication 280G-QS001A-EN-P - December 2008 5Figure 4 Control Power Media System Overview➏ Control Power Media Patchcords - PatchCord cable w

Strona 17 - Table 11 DeviceNet Media

6 Publication 280G-QS001A-EN-P - December 2008ArmorStart with ArmorConnect Connectivity Terminal Designations ArmorConnect Cable RatingsThe Arm

Strona 18 - Table 13 Sealing Caps

Publication 280G-QS001A-EN-P - December 2008 7Group Motor Installations for USA and Canada MarketsThe ArmorStart Distributed Motor controllers

Strona 19 - 19

8 Publication 280G-QS001A-EN-P - December 2008The working space around the ArmorStart may be minimized as the ArmorStart does not require exami

Strona 20 - Trademark List

Publication 280G-QS001A-EN-P - December 2008 9LED Status Indication The LED Status Indication provides 4 status LEDs and a Reset button. The LE