The tag being read was Cat. No. 56RRF-TG-30. This tag has 28 blocks. The
maximum block number is 27, as the first block is 0. Each block has 4 bytes. The
maximum byte number is 3, as the first byte is 0.
The IC Ref is the last byte reported.
Get Version Information
The Get Version Information command will retrieve the firmware version
information from the transceiver.
Set the following values in the output image table:
a. xx:O.Channel[0].Command = 33
b. xx:O.Channel[0].Address = 0
c. xx:O.Channel[0].BlockSize = 0
d. xx:O.Channel[0].Data[0] = 0
e. xx:O.Channel[0].Length = 0
f. xx:O.Channel[0].Reset = 0
g. xx:O.Channel[0].Timeout = 0
h. xx:O.Channel[0].UIDLow = 0
i. xx:O.Channel[0].UIDHi = 0