20 Industrial Integrated Display Computers
Rockwell Automation Publication 6181P-IN010F-EN-P - July 2013
Connect to a Network
The computers have 2 Gb LAN ports. The computers connect to an Ethernet network by using
CAT5 or CAT5E twisted-pair Ethernet cabling with RJ45 connectors.
Real Time Clock (RTC) Battery
This computer contains a lithium battery that must be replaced during the life of the computer.
The computers use nonvolatile memory that require a battery to retain system information when
power is removed. The battery is beside the DIMM1 slot.
The battery life depends on the amount of time the computer is powered on.
IMPORTANT
To prevent performance degradation of Ethernet communication, do not subject the computer
or cables to extreme radiation or conducted high-frequency noise.
Proper cable routing and power conditioning is required to be sure of reliable Ethernet
communication in an industrial environment. Rockwell Automation recommends that you
route all Ethernet cabling through dedicated metal conduits. Installing ferrite bead filters at
the cable ends can also improve reliability.
Performance and Non-display Computer Standard Computer
On-time
(hrs/wk)
Expected Battery
Life (yrs)
04
40 5.5
80 7