Rockwell-automation 61C613 16 Channel Analog Input Module Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation 61C613 16 Channel Analog Input Module. Rockwell Automation 61C613 16 Channel Analog Input Module User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
  
  
 
 
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 -  

      

Strona 2

2Ć2CHAN0 Ć 7CHAN8 Ć 15PIN 1PIN 116 CHANNELLOW LEVEL INFigure 2.1Ć Module Faceplate

Strona 3 - Table of Contents

2Ć3  The input module contains sixteen analog input channels withsoftwareĆselectable features. These channels are connected th

Strona 4 - 

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 5 -   

3Ć13.0 INSTALLATIONThis section describes how to install and remove the module and itscable assembly.3.1 Initial InstallationUse the following procedu

Strona 6

3Ć2Table 3.2Ć DCS 5000 Slot ConfigurationSlot # 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1522222222222222baseaddress(HEX)Switch--200003000040000500006000070

Strona 7 -  

3Ć3b. Compile the BASIC tasks TEST613.CNF, SETUP613.BAS, andKYBD613.BAS.c. Load the three tasks listed in step b" onto the CPU.d. Use the RUN AL

Strona 8

3Ć4  Use the following procedure to replace a module:Step 1. Turn off power to the rack and all connections.Step 2. Remove the con

Strona 9 - DESCRIPTION

4Ć14.0 PROGRAMMINGThis section describes how the data is organized in the module andprovides examples of how the module is accessed by the application

Strona 10 - Figure 2.1Ć Module Faceplate

4Ć2Table 4.1Ć Memory LocationsLocation (M+0) status/error from module; command from softwareLocation (M+1) command from softwareLocation (M+2) return

Strona 11 -   

4Ć34.2.2 Module InitializationWhenever power is turned on to the rack or the module is reset, it isnecessary to initialize the module. Module initiali

Strona 12

 Copyright Reliance Electric Industrial Company 1992.ReSource is a trademark of Reliance Electric Company.Reliance, AutoMax and AutoMate are regi

Strona 13 - 3.0 INSTALLATION

4Ć4   In configuring the channel input, you define the type of signal that willbe converted on a particular channel. If an i

Strona 14 - Verification

4Ć5Before you attempt to define the signal type, you must first set themodule's channel register pointer to the desired value. Refer tosection 4.

Strona 15

4Ć6inputs as temperature inputs for degrees F. A value of 320 must beused as the offset.Before you attempt to configure the offset, you must first set

Strona 16 -   

4Ć7The data returned is a signed integer. Location (M+1) is the leastsignificant byte, and location (M+2) is the most significant byte.Depending upon

Strona 17 - 4.0 PROGRAMMING

4Ć816130 ąIF BIT_SET@(STATUS%,0) THEN GOTO 1620016140 NEXT I%16150 ERR_CODE% = Ć1 \! Retry Error16160 RETURN16197 REM16198 REM Read error code16199 RE

Strona 18 - 4.2 Command Descriptions

4Ć9     The following example is an AutoMate program that will write aRESET command to the module and read the read

Strona 19 - 4.2.3 Write Channel Number

4Ć10     The following example is an AutoMate program that will read dataconverted in the continuous mode from the modu

Strona 20 -  Used with RTD inputs

4Ć114.4 RestrictionsThis section describes limitations and restrictions on the use of thismodule.4.4.1 Rack Slot LocationThis module cannot be used in

Strona 21 - 4.2.5 Configure Channel Slope

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 22

5Ć15.0 DIAGNOSTICS ANDTROUBLESHOOTINGThis section explains how to troubleshoot the module and fieldconnections.5.1 Incorrect DataProblem: The data is

Strona 23 - 4.3 Programming Examples

ITable of Contents1.0 Introduction 1Ć1...2.0 Mechanical/Electrical Description 2Ć1...

Strona 24

5Ć2  Problem: Error code 31" or 16" appears on the DCS 5000/AutoMaxprocessor module's LEDs, or register 3764 in the A30 or

Strona 25

AĆ1Appendix ATechnical SpecificationsAmbient Conditions Storage temperature: -25C Ć 85C Operating temperature: 0C Ć 60C Humidity: 5Ć95% nonĆcondens

Strona 26

AĆ2  Offset temperature coefficient+Volts/Deg. C (max): 0.0025 Ć +12.50mV range0.005 Ć +25.00mV range0.01 Ć +50.00mV range0.02 Ć

Strona 27 - 4.4 Restrictions

AĆ3Appendix A(Continued)Linear Performance (14 bits)The following table details guaranteed accuracy and repeatability as compared toNational Bureau of

Strona 28

AĆ4Appendix A(Continued)Thermocouple Performance (14 bits)ANSI Thermocouple Curve Conformance: + 0.2 deg F maxThe following table details guaranteed a

Strona 29 - TROUBLESHOOTING

Appendix BModule Block Diagram16 Channel Analog Input Module (61C613)FieldSensorsJTJTIN 1IN 8ACCUMUXIN 9IN 16CJCLOCAL+–CJCEXPANSION CONTROL BUSCJC

Strona 30 -   

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 31 - Appendix A

CĆ1Appendix CModule Connections-Channels 8Ć15Pin135791113151719212325272931333537394143454749Pin2468101214161820222426283032343638404244464850Signaln.

Strona 32 -  

CĆ2Appendix C(Continued)Module Connections-Channels 0Ć7Pin135791113151719212325272931333537394143454749Pin24681012141618202224262830323436384042444648

Strona 33

DĆ1Appendix DRelated ComponentsM/N 61C614 Thermocouple/Voltage Termination PanelThis assembly consists of a rackĆmountable termination panel that can

Strona 34

   #" & $  ! &

Strona 35 - Appendix B

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 36

EĆ1  (M+0) (M+1) (M+2) Commandă49 0 0 module resetăă0 0 *1 module initializationă20 ch. # *2 write channel numberch.config.ă10

Strona 37 - Appendix C

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 38

FĆ1    ăăăă4 Module busy; can't accept commandăăăă5 Scan in progress; can't accept commandăăăă7 Illeg

Strona 39 - Appendix D

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 40

GĆ1    20,040 0000 SLOT # 4 CHANNEL # 020,041 0023 J T/C TYPE CODE NUMBER Ć CHANNEL # 020,042 0001 MĆSLOPE VALUE Ć C

Strona 41 -  

GĆ2 20,114 0011 SLOT # 4 CHANNEL # 1120,115 0012 5.0VĆ12b TYPE CODE NUMBER Ć CHANNEL # 1120,116 0001 MĆSLOPE VALUE Ć CHANNEL # 112

Strona 42

HĆ1Appendix HAutoMate Program CommandRegister TableREGISTER DATA ADDRESS COMMENTS20,000 0049 M + 0 RESET20,001 0000 M + 1 NOOP20,002 0000 M + 2 NOOP20

Strona 43 -  

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 44

IĆ1     REGISTER ăDATA COMMENTSą3500 0Ć10000 ANALOG INPUT Ć SLOT # 4 CHANNEL ă0ą3501 0Ć10000 ANALOG INPUT Ć SL

Strona 45 -  

III  Figure 2.1 Ć Module Faceplate 2Ć2...Figure 2.2 Ć Typical Input Circuit 2Ć3...

Strona 46 -  

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 47 - Appendix H

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 48

For additional information1 Allen-Bradley DriveMayfield Heights, Ohio 44124 USATel: (800) 241-2886 or (440) 646-3599http://www.reliance.com/automaxCop

Strona 49 -  

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 50

1Ć1 The 61C613 is an input module for the AutoMate 30/40 and DCS5000/AutoMax. It features 16 individuallyĆisolated analog inputscapab

Strona 51

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Strona 52 - 1 Allen-Bradley Drive

2Ć12.0 MECHANICAL/ELECTRICALDESCRIPTIONThe following is a description of the faceplate, field terminationconnectors, and electrical characteristics of

Komentarze do niniejszej Instrukcji

Brak uwag