Rockwell Automation Publication 842E-UM002A-EN-P - November 2013 37
Configuring the 842E-CM Encoder Using the Logix Designer Application Chapter 5
5. Click Apply.
6. Select the Master Feedback category; the Master Feedback
specification dialog box opens.
7. Select Type: Hiperface. This is currently the only choice for Type.
8. Set the resolution for the encoder; set the number of turns as
appropriate to your encoder. The effective resolution should be
displayed. The configuration for multi-turn is shown below. For
single turn, Turns should be 1.
9. Click Apply.
10. Select the Scaling category and edit the default values as
appropriate to your application. If you make changes, click Apply.