Rockwell-automation AADvance Controller Solutions Handbook Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation AADvance Controller Solutions Handbook. Rockwell Automation AADvance Controller Solutions Handbook User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Solutions Handbook

AADvance The Next Step in Automation AADvance Controller Solutions Handbook Issue: 09 DOCUMENT: 553631 (ICSTT-RM447J_EN_P)

Strona 2

   x Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Estimate Module Supply Power Dissipatio

Strona 3

   7-6 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) The processor base unit provides the

Strona 4

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-7 T9100 Base Unit Specification Table 22: T9100 Processor Base Unit Specification Att

Strona 5 - Issue Record

   7-8 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) T9300 I/O Base Unit (3 way) The AADva

Strona 6

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-9 The bus and power connections from the processor base unit enter the backplane at the

Strona 7

   7-10 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) T9310 Expansion Cable Assembly The T

Strona 8 - Contents

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-11 T9310 Extension Cable Specification Table 24: T9310 Extension Cable Specification

Strona 9

   7-12 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) T9401/2 Digital Input Module, 24V dc

Strona 10

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-13 T9401/2 Digital Input Module Specification Table 25: T9401/2 Digital Input Module

Strona 11

   7-14 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) T9801/2/3 Termination Assemblies for

Strona 12

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-15 T9801/2/3 Digital Input Termination Assembly Specification Table 26: T9801/2/3 Dig

Strona 13 - Chapter 1

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: xi Power Supply Requirements ...

Strona 14

   7-16 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) T9431/2 Analogue Input Module, 8/16

Strona 15

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-17 T9431/2 Analogue Input Module Specification Table 27: Analogue Input Module Specif

Strona 16

   7-18 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Weight T9431: 280g (10 oz.) T9432: 3

Strona 17 - Environmental Specifications

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-19 T9831/2/3 Analogue Input Termination Assembly Specification Table 28: Analogue Inp

Strona 18

   7-20 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) T9451 Digital Output Module, 24V dc,

Strona 19

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-21 T9451 Digital Output Module Specification Table 29: Digital Output Module Specific

Strona 20

   7-22 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) * SIL3 is the maximum achievable for

Strona 21

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-23 T9851/2 Digital Output Termination Assembly Specifications Table 30: Digital Outpu

Strona 22 - 1129711X

   7-24 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) T9481/2 Analogue Output Module The

Strona 23

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-25 T9481/2 Analogue Output Module Specification Table 31: Analogue Output Module Spec

Strona 25

   7-26 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Maximum range 0 - 750limited b

Strona 26

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-27 T9881/2 Analogue Output Termination Assembly Specification Table 32: Analogue Outp

Strona 27

   7-28 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) This page intentionally le

Strona 28 -  Connections: Maximum 255

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 8-1 The AADvance Workbench environment facilitates the task of automation throughout the

Strona 29

   8-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Support for Variable Types For each c

Strona 30

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 8-3 Aids to Software Development The development environment automatically verifies the

Strona 31

   8-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) DIN Rails Fitting You can install the

Strona 32

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 9-1 The AADvance controller is supplied as 'open' type equipment, ready for ins

Strona 33 - Function:

   9-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) CAUTION HEAT DISSIPATION AND ENCLOS

Strona 34

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 9-3 Base Units, DIN Rail installations and Expansion Cables Base units fit together side

Strona 35 - Modbus Master

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-1 An AADvance system consists of an AADvance controller, an external operator's wo

Strona 36

   9-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Power Supply Requirements A controlle

Strona 37

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 9-5

Strona 39 - Compiler Verification Tool

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 10-1 Bases Part No. Part Description T9100 Processor base unit T9300 I/O base unit (3 way

Strona 40

   10-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) T9831 Analogue input TA, 16 channel,

Strona 41

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 10-3 T9903 Replacement coding pegs (pack of 20) T990

Strona 42

   10-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) T9902: SMF Omni-Block, Surface Moun

Strona 43

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 11-1 Glossary of Terms A accuracy The degree of conformity of a measure to a standar

Strona 44

   11-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) blanking cover A plastic moulding to

Strona 45 - Compact Module Design

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 11-3 Glossary of Terms consumer The consuming controller requests the tag from the

Strona 46

   1-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) The significant benefits of the AADva

Strona 47 - Termination Assemblies

   11-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) fault reset button The momentary act

Strona 48

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 11-5 Glossary of Terms hot swap See live insertion. I I/O base unit A backplane ass

Strona 49

   11-6 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) M manual call point A component of a

Strona 50

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 11-7 Glossary of Terms processor module The application execution engine of the AADv

Strona 51 - Chapter 2

   11-8 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) SFF Safe Failure Fraction. Given by

Strona 52

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 11-9 Glossary of Terms U U Rack unit. A unit of measure used to describe the height

Strona 54

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 12-1 For more information about the AADvance system refer to the associated Rockwell Auto

Strona 55

   12-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) 553847 PFH avg and PFDavg Data This

Strona 56

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-3 Single input modules are designed to meet SIL3 and in the most basic simplex configur

Strona 57

   1-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Time Stamp Accuracy 10ms Safety ac

Strona 58

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-5 Throughput time is the time from input change to output action. Due to the discrete n

Strona 59

   1-6 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Functional Stress 5Hz to 9Hz Con

Strona 60

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-7 Controller TUV Certification TÜV Certification TÜV is the safety certifying authorit

Strona 61

   ii Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) This page intentionally left

Strona 62

   1-8 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Products Covered The products investi

Strona 63

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-9 Listed Accessories for use with PLCs: 9100 Processor Backplane, 9300 I/O Backplane, 9

Strona 64

   1-10 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Certificate The AADvance controller

Strona 65 - Chapter 3

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-11 The AADvance controller has also been evaluated under certificate IECEx UL 12.0032X

Strona 66

   1-12 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) KCC-EMC Registration KCC- EMC Regis

Strona 67 - Data Input and Output

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-13 Main Components Hardware Components Each controller is built from a standard range o

Strona 68

   1-14 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) AADvance Workstation Software and A

Strona 69

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-15 Programs can be simulated and tested and tested on the computer before downloading t

Strona 70

   1-16 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Controller Functionality SNTP The AA

Strona 71

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-17 Note: The CIP Protocol is intended to allow AADvance users to exchange data between

Strona 72

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: iii Notice In no event will Rockwell Automation be responsible or liable for indir

Strona 73 - Chapter 4

   1-18 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Figure 1: Example HART Pass-through

Strona 74

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-19 The physical network is considered a "Black Channel" so the design of the

Strona 75 - Mixed I/O Architectures

   1-20 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Peer-to-Peer AADvance provides the c

Strona 76

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-21 Safety Related Peer-to-Peer Configurations The following Peer-to-Peer configuratio

Strona 77 - Distributed Architectures

   1-22 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Peer-to-Peer Settings TÜV Certified

Strona 78

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-23 Modbus Master The AADvance controller can be used as a Modbus master to one or mor

Strona 79

   1-24 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Modbus Master Hardware and Physical

Strona 80

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-25 Controller IP Address Setting The AADvanceDiscover Utilility uses a discovery and co

Strona 81 - Chapter 5

   1-26 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Ethernet Forwarding When enabled, th

Strona 82

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-27 Transparent Communication Interface (TCI) The AADvance controller processor module p

Strona 83 - Dual I/O Channel Capacity

   iv Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Notes and Symbols used in this manual

Strona 84

   1-28 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Technical Features TUV Approved Op

Strona 85 - Adding I/O Channel Capacity

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-29 System Modification and On-line Updates The AADvance controller has a modular desi

Strona 86

   1-30 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) When new I/O modules need to be adde

Strona 87 - Chapter 6

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-31 ControlFLASH Firmware Upgrades The AADvance controller supports upgrades of processo

Strona 88

   1-32 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Physical Features An innovative fe

Strona 89

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-33 The depth of the base unit (18mm) excludes the parts of the backplane connectors tha

Strona 90

   1-34 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Base units are moulded from a simila

Strona 91 - Specify I/O Base Units

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-35 Module Locking Mechanism Each module carries a locking mechanism, which secures the

Strona 92

   1-36 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Part No: Digital Input Fuses T9901

Strona 93

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 1-37 Ethernet, Serial Data and Power Connections The external connections for Earthing, E

Strona 94

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: v Issue Record Issue Date Comments 01 Dec 2008 First Issue 02 Feb 2009 03 Feb 201

Strona 95 - Chapter 7

   1-38 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Field Wiring Connections Field conne

Strona 96

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 2-1 An AADvance controller can be configured to manage non-safety up to SIL 3 safety rela

Strona 97

   2-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) SIL2 Fail-safe Architecture The follo

Strona 98

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 2-3 SIL2 Fault Tolerant Input Architectures A SIL2 fault tolerant input architecture can

Strona 99 - T9100 Processor Base Unit

   2-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) SIL2 Output Architecture A SIL2 outpu

Strona 100

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 2-5 SIL2 Fault Tolerant Input High Demand Architecture A SIL2 fault tolerant "High D

Strona 101

   2-6 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Position Module Type I/P A 2 × T9401/

Strona 102

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 2-7 SIL3 Fail-safe I/O, Fault Tolerant Processor A SIL3, fail-safe I/O with a fault toler

Strona 103

   2-8 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Table 9: Modules for SIL3 Fail-saf

Strona 104

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 2-9 Table 10: Modules for SIL3 Fault Tolerant Architectures Position Module Type I/P

Strona 105

   vi Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Forward This technical manual describe

Strona 106

   2-10 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) SIL3 TMR Input and Processor, Fault

Strona 107

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 2-11 CPU A & CPU B 3 × T9110 Processor Module, T9100 Processor Base Unit, O/P A 2 ×

Strona 108

   2-12 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Table 14: Output Modules Modul

Strona 109

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 2-13 This page intentionally left blank

Strona 111

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 3-1 The controller supports a range of architectures. This chapter describes how to build

Strona 112

   3-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Low Demand SIL2 Architecture This is

Strona 113

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 3-3 Data Input and Output A controller can support up to 48 I/O modules in total (on 16

Strona 114

   3-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Adding a 2nd Processor for a Higher S

Strona 115

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 3-5 Dual Architecture for Fault Tolerant Applications Fault Tolerant Input and SIL3 Outpu

Strona 117

   3-6 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Increasing I/O Capacity The capacity

Strona 118

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 3-7 Triple Modular Redundant Architecture A SIL3 TMR architecture offers the highest leve

Strona 119

   3-8 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) You can add further groups of three i

Strona 120

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 4-1 It is straightforward to implement single, dual and triple I/O architectures for a co

Strona 121

   4-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller)

Strona 122

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 4-3 Mixed I/O Architectures An application might readily justify a dual processor and dua

Strona 123 - Chapter 8

   4-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Mixed Safety Integrity Levels Such is

Strona 124

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 4-5 Distributed Architectures AADvance is designed to support a distributed safety archit

Strona 125

   4-6 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Typical Network Applications A typica

Strona 126

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 4-7 Controller Network Connectors The controller features six autosensing 10/100BASE-TX E

Strona 127 - Chapter 9

   viii Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Contents Chapter 1 The AADvan

Strona 128

   4-8 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) This page intentionally lef

Strona 129 - Assemblies of Base Units

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 5-1 The AADvance design concept provides an expandable solution for every application thr

Strona 130

   5-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Simplex I/O Channel Capacity When you

Strona 131

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 5-3 Dual I/O Channel Capacity When you need I/O modules arranged in dual redundant format

Strona 132

   5-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Triple Modular Redundant Channel Capa

Strona 133 - Chapter 10

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 5-5 Adding I/O Channel Capacity You can specify a new controller to have the precise quan

Strona 134

   5-6 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Redundancy and Fault Tolerance A sign

Strona 135

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 6-1 This chapter provides a list of key information needed to specify a new AADvance cont

Strona 136

   6-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Define a New System The charts use m

Strona 137 - Glossary of Terms

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 6-3

Strona 138

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: ix Serial Communications ...

Strona 139

   6-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller)

Strona 140

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 6-5 Choosing Termination Assemblies The use of termination assemblies gives the AADvance

Strona 141

   6-6 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Estimate AADvance Controller Weight U

Strona 142

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 6-7 Estimate Module Supply Power Dissipation and Field Loop Power Dissipation Module su

Strona 143

   6-8 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) This page intentionally lef

Strona 144

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-1 This chapter provides a brief technical overview and technical specification of each

Strona 145

   7-2 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) T9110 Processor Module The T9110 pro

Strona 146

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-3 If a controller uses two or three processor modules, and one processor module develop

Strona 147 - Additional Resources

   7-4 Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: Solutions Handbook (AADvance Controller) Processor Module Specification Table

Strona 148 - Regional Offices

  Document: 553631 (ICSTT-RM447J_EN_P) Issue: 09: 7-5 T9100 Processor Base Unit Every AADvance controller has one T9100 processor base uni

Komentarze do niniejszej Instrukcji

Brak uwag