Rockwell-automation FactoryTalk Historian SE ProcessBook 3.2 User Guid Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Rockwell-automation FactoryTalk Historian SE ProcessBook 3.2 User Guid. Rockwell Automation FactoryTalk Historian SE ProcessBook 3.2 User Guide User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - PROCESSBOOK USER GUIDE

PROCESSBOOK USER GUIDE PUBLICATION HSEPB-UM024A-EN-E–June 2012 Supersedes Publication HSEPB-UM023A-EN-E

Strona 2 - Copyright

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide x Values ... 162 Add a D

Strona 3

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 82 Font To determine what type of formatting is applicable for each symbol, refer to the t

Strona 4

4 ● Work with a Display ● ● ● ● ● 83 Depending on the symbol type, the following elements change to the color displayed on the button.  Symbols t

Strona 5

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 84 3. Click the arrow on the right side of the Fill Color button to display the color palet

Strona 6

4 ● Work with a Display ● ● ● ● ● 85 Line Weight To determine what type of formatting is applicable for each symbol, refer to the table of editable

Strona 7

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 86 Line Ends To determine what type of formatting is applicable for each symbol, refer to th

Strona 8

4 ● Work with a Display ● ● ● ● ● 87 ToolTip Statistics In Run mode, hover your mouse over a point on a dynamic symbol to display a ToolTip with su

Strona 9

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 88 Time Range and Playback Toolbar The Time Range and Playback toolbar allows you to play,

Strona 10

4 ● Work with a Display ● ● ● ● ● 89 Time Tracker The time tracker shows the Display range (page 93) and available Scroll period (page 92). Go to

Strona 11 - Contents

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 90 Pause/Play The button drives the playback feature. The Play button changes to the pause

Strona 12

4 ● Work with a Display ● ● ● ● ● 91 Scroll Options Dialog Box Use the Scroll Options dialog box to set the default behavior settings for the Time

Strona 13

● Contents ● ● ● ● ● xi Select a Default Symbol for Data Favorites ... 197 Search for Data Favorites ...

Strona 14

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 92 Review the following for additional information: Display Range (page 93) Use any accepted

Strona 15

4 ● Work with a Display ● ● ● ● ● 93 Change the Scroll Period There are several ways to change the scroll period:  Hover the mouse next to the l

Strona 16

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 94 A display must be reverted to re-establish any build time configuration time ranges for i

Strona 17

4 ● Work with a Display ● ● ● ● ● 95  Use the Time Tracker arrow keys to move the display range current position.  Click the scroll bar on eith

Strona 18

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 96 Click View > Layers. The Layers dialog box appears. 3. Review the following for addi

Strona 19 - Introduction

4 ● Work with a Display ● ● ● ● ● 97 4. Click New Layer. The New Layer dialog box appears. A default name comprised of the word Layer prefixed to

Strona 20

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 98 Assign Symbols to Layers If you have at least one layer in a display, you can assign symb

Strona 21 - 1 ● Introduction

4 ● Work with a Display ● ● ● ● ● 99  You cannot group symbols on locked layers into a composite symbol, but the layers may be locked after the s

Strona 22

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 100 Migrate Displays to Another FactoryTalk Historian Server When you want to use an existin

Strona 23 - Essentials

4 ● Work with a Display ● ● ● ● ● 101  0 - [default] the Point ID is used to match a missing tag before the stored point name.  1 - uses the ta

Strona 24 - Servers and Connections

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide xii Connector Symbol ... 211 Connect T

Strona 25

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 102

Strona 26 - Network Errors

Chapter 5 103 Visualize Data with Symbols Symbols are the building blocks of a FactoryTalk Historian ProcessBook display.  Dynamic symbols allow

Strona 27

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 104 Plot Title The title of the trend being configured. The plot title can be blank, but a t

Strona 28 - Workspace

5 ● Visualize Data with Symbols ● ● ● ● ● 105 4. When you release the mouse button, the Define Trend (page 110) dialog box appears. 5. Under Plo

Strona 29 - Display

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 106  Tag Search (page 231)  PI calculation (page 248) (data set)  ODBC (page 254) (dat

Strona 30 - Run Mode and Build Mode

5 ● Visualize Data with Symbols ● ● ● ● ● 107 10. Under Scale, select Single Scale or, if you have more than one trace, you may select Multiple Sc

Strona 31 - Add-Ins

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 108 Autorange The trend displays with the value scale ending at the closest available major

Strona 32 - Menus and Toolbars

5 ● Visualize Data with Symbols ● ● ● ● ● 109 FactoryTalk Historian ProcessBook allows you to create custom placeholders for a symbol based on a su

Strona 33 - Toolbar Buttons

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 110 In Build mode simply click the plot you want to move. Selection handles appear around th

Strona 34 - Browser Toolbar

5 ● Visualize Data with Symbols ● ● ● ● ● 111 shapes, and you can set the types of point information included with a trend. The Define Trend dialog

Strona 35 - Set a Home Page

● Contents ● ● ● ● ● xiii Connect to an AF Database ... 239 Element Search ...

Strona 36

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 112 Display Format Tab Review the following for additional information:

Strona 37 - Add/Edit Bookmarks

5 ● Visualize Data with Symbols ● ● ● ● ● 113 Legend Check or clear options in this group box for displaying the tag name, server name, descriptio

Strona 38 - Keyboard Shortcuts

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 114 The Trace Format tab gives you an alternate way to update formatting changes. Plot Elem

Strona 39 - Assign a Keyboard Shortcut

5 ● Visualize Data with Symbols ● ● ● ● ● 115 Element Format group box - select formatting options for the selected plot element. Your choices are

Strona 40 - Preference Settings

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 116 Under Plot Arrangement, select the number of rows and columns you want. The following ex

Strona 41 - General Preferences

5 ● Visualize Data with Symbols ● ● ● ● ● 117 Configure Trend Scale The Trend Scale dialog box provides easy access to the value scale settings for

Strona 42

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 118 Autorange Sets the value scale using the minimum and maximum tag values between the tren

Strona 43

5 ● Visualize Data with Symbols ● ● ● ● ● 119 Drag Zoom Drag Zoom lets you contract the time scale of a trend. 1. With the Run mode pointer, click

Strona 44

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 120 used as the center of the zoomed trend. See Trend Cursor (page 120), for more informatio

Strona 45

5 ● Visualize Data with Symbols ● ● ● ● ● 121 Add a Trend Cursor To add a trend cursor: 1. Notice whether the time scale appears at the bottom and

Strona 46 - Display Window

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide xiv ODBC Driver Manager ... 271 ODBC Drive

Strona 47

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 122 To remove one trend cursor but not all of them, click the trend cursor and drag it to th

Strona 48 - Trend Preferences

5 ● Visualize Data with Symbols ● ● ● ● ● 123 FactoryTalk Historian ProcessBook uses an algorithm to identify the peaks and valleys of data values

Strona 49

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 124 Grid Line Labels Configure the labels for the value scale using single or multiple scal

Strona 50 - Trend Elements Preferences

5 ● Visualize Data with Symbols ● ● ● ● ● 125 Autorange scale The value scale is determined by a calculation based on minimum and maximum values in

Strona 51

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 126 flat plot area. These default ranges are not applied if the trace in question is on a si

Strona 52 - Page Setup for Printing

5 ● Visualize Data with Symbols ● ● ● ● ● 127 Full Timestamp Labels the start and end time limits with the date and time. When space permits, the e

Strona 53 - Printer Setup

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 128 1. Open a trend in Run mode. 2. Hover your mouse pointer over the trend's legend.

Strona 54 - Historian ProcessBook

5 ● Visualize Data with Symbols ● ● ● ● ● 129 Trace markers If there are too many values to plot based on the size of the trend, the display resolu

Strona 55

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 130 If you create an ad hoc trend display and then choose to save it for future use, it appe

Strona 56

5 ● Visualize Data with Symbols ● ● ● ● ● 131  Save an ad hoc trend display as an independent display by clicking it and using the Save As comman

Strona 57 - Work with a ProcessBook

● Contents ● ● ● ● ● xv Edit, Update, or Break Links ... 291 How Links Are Stored ...

Strona 58 - Open an Existing ProcessBook

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 132 Convert Trends This process is used to convert VAX graphics for use with a PC. 1. On th

Strona 59 - Add ProcessBook Entries

5 ● Visualize Data with Symbols ● ● ● ● ● 133 3. Type the display name of the graphic you want to convert and press Enter. Repeat for each file yo

Strona 60

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 134 This case plotted 10-minute intervals of two points, A and B, for the last hour. Point A

Strona 61 - Linked Display Entry

5 ● Visualize Data with Symbols ● ● ● ● ● 135 A third plot is somewhat correlated: Somewhat correlated. In the case of the third plot, a regressio

Strona 62

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 136 Draw an XYPlot To draw an XYPlot: 1. In Build mode, click Draw > XYPlot, or on the D

Strona 63 - 3 ● Work with a ProcessBook

5 ● Visualize Data with Symbols ● ● ● ● ● 137 General Tab  Plot Title - Type a plot title. Change it later if you wish.  Tags in Plot - Selec

Strona 64 - Linked ProcessBook Entries

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 138  FactoryTalk Historian calculation (page 248) (data set)  ODBC (page 254) (data set)

Strona 65

5 ● Visualize Data with Symbols ● ● ● ● ● 139 Configure Pairings Once the tags are listed in the Tags in Plot list, configure the method for pairin

Strona 66

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 140 Y Tags, paired by timestamps To pair values by time, rather than by list position, choos

Strona 67 - Arrange ProcessBook Entries

5 ● Visualize Data with Symbols ● ● ● ● ● 141 Scale Box In the Scale Box, set the scale ranges for all tags. Single Y Scale Combines all Y tag valu

Strona 68 - Book View

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide xvi Installed Files ... 307 S

Strona 69 - Turn Pages in Book View

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 142 Plot Time You can set the time for each tag as it is highlighted in the Tags in Plot bo

Strona 70 - Entries in Book View

5 ● Visualize Data with Symbols ● ● ● ● ● 143 Display Format Tab Review the following for additional information:

Strona 71 - Outline View

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 144 Legend Choose the legend elements that appear in the XYPlot.  Tag Name Lists the entri

Strona 72

5 ● Visualize Data with Symbols ● ● ● ● ● 145 Plot Format Tab In the Plot Format tab of the Define XYPlot dialog box, you can select colors and sty

Strona 73 - ProcessBook Preferences

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 146 Element Format After you select an element in the Plot Element list, available formattin

Strona 74

5 ● Visualize Data with Symbols ● ● ● ● ● 147 XYPlot Statistics The XYPlot Statistics dialog box allows you to view and export raw data values and

Strona 75 - Save a View of Your Displays

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 148 2. In the Options list, select Raw Data or Statistics.

Strona 76 - Save and Close a ProcessBook

5 ● Visualize Data with Symbols ● ● ● ● ● 149 To save this data to a text file: 1. Click Save Data to File button. The Save As dialog box appears

Strona 77 - Properties

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 150 <index>, <time>, <value>, <status> <index>, <time>,

Strona 78

5 ● Visualize Data with Symbols ● ● ● ● ● 151 To calculate b, the following equation is used: Once m and b are known, the value of y that intersec

Strona 79 - Modify a ProcessBook Title

● Contents ● ● ● ● ● xvii Color Section ... 332 Line Style Section ...

Strona 80

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 152 Interpreting an XYPlot In FactoryTalk Historian ProcessBook the XYPlot is a dynamic symb

Strona 81

5 ● Visualize Data with Symbols ● ● ● ● ● 153 In the figure above, if there had been more than one Y tag, each one would be displayed on a differen

Strona 82 - File Sharing Capability

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 154 2. Hold the left mouse button down while dragging a rectangle to cover the appropriate

Strona 83

5 ● Visualize Data with Symbols ● ● ● ● ● 155 Original plot Drag Zoom Completed The zoom area must be smaller than the plot area and cannot includ

Strona 84

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 156 Change Time Range Feature To change time range: 1. Click View > Time Range or click

Strona 85 - Work with a Display

5 ● Visualize Data with Symbols ● ● ● ● ● 157 In the XYPlot below, you can see an XYPlot cursor at the Y axis that is not yet intersecting any poin

Strona 86 - OLE Objects

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 158 The information on the XYCursor point pair is shown in a box on each axis. If the tags a

Strona 87 - Open a Display

5 ● Visualize Data with Symbols ● ● ● ● ● 159 Example 1: Comparing Values for Two FactoryTalk Historian Tags In this example we will create an XYP

Strona 88

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 160 1. Plot the temperature of Boiler1 (the B1Temp tag) on the X-axis of an XYPlot and the

Strona 89 - Zoom Display Size

5 ● Visualize Data with Symbols ● ● ● ● ● 161 Example 4: Comparing a Batch Run to a Standard An engineer wants to compare sample measurements taken

Strona 90 - Full Screen Mode

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide xviii Knowledgebase ... 349 Worldwi

Strona 91 - Search for a Display

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 162 Additional Dynamic Symbols Values A value is the reading obtained at the specified end

Strona 92 - Save a Display

5 ● Visualize Data with Symbols ● ● ● ● ● 163 When you release the mouse button, the Define Value dialog box is displayed. 4. In the Server list,

Strona 93 - Display Settings

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 164 5. In the Tag box, type the name of the tag you want to display in the value box. -or-

Strona 94 - Display Scrolling Properties

5 ● Visualize Data with Symbols ● ● ● ● ● 165 Custom (#,##0.00, 0%) Allows you to enter your own number format. See the Table of Format Values (pag

Strona 95 - Drawing Tools

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 166 You can add a button to your drawing that: For example: display (.pdi file) on a web sit

Strona 96 - Organizing Symbols

5 ● Visualize Data with Symbols ● ● ● ● ● 167 If you know the file or macro name, then you can type this directly in the Action box. The name of th

Strona 97 - Drawing Area

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 168 10. Click OK. The button is added to your display. Bars A Bar shows the current value

Strona 98 - Drawing Grid

5 ● Visualize Data with Symbols ● ● ● ● ● 169 You can draw a bar using the current line style, line color, and fill attributes. 1. In Build mode,

Strona 99 - Formatting

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 170 5. In the Server list, select the server to use for manually entered tags. If the serve

Strona 100 - Line Color

5 ● Visualize Data with Symbols ● ● ● ● ● 171 The Upper and Lower lists are renamed Right and Left when you select Horizontal orientation. The Samp

Strona 101 - Fill Color

Chapter 1 1 Introduction As the easy-to-use graphical display interface to the Rockwell Automation FactoryTalk Historian system, FactoryTalk Histo

Strona 102 - Background Color

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 172 The default font is the font of the display. Digital tags show the value of the digital

Strona 103 - Line Style

5 ● Visualize Data with Symbols ● ● ● ● ● 173 Horizontal Bar with scales (outside and inside) The lengths of major and minor tick marks is a perce

Strona 104 - Formatting Paintbrush

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 174 There are major tick marks for each digital state, if the string value for the digital s

Strona 105 - ToolTip Statistics

5 ● Visualize Data with Symbols ● ● ● ● ● 175 is 50 or below, the symbol appears blue. Above 50, the symbol appears red. A color and sometimes a bl

Strona 106

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 176 3. In the Server list, select the server to use for entered tags. If a server and tag a

Strona 107 - 4 ● Work with a Display

5 ● Visualize Data with Symbols ● ● ● ● ● 177 tags, the state name is displayed in these boxes. For other tag types, an estimate is made based on t

Strona 108

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 178 ProcessBook symbols, this symbol is not sized by dragging an area on the display. Instea

Strona 109 - Scroll Options Dialog Box

5 ● Visualize Data with Symbols ● ● ● ● ● 179 4. When you finish typing, press ESC or click outside the text block. Move a Text Block To move a t

Strona 110 - Scroll Period

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 180 Rectangle, Square, Arc, Ellipse, and Circle Symbol Using the drawing tools, you can

Strona 111 - Display Range

5 ● Visualize Data with Symbols ● ● ● ● ● 181 Press SHIFT to change the angle in 15-degree increments. When the arc is first drawn, the handle for

Strona 112

● ● ● ● ● Copyright ii Contact Rockwell Automation Customer Support Telephone — 1.440.646.3434 Online Support — http://www.rockwellautomation.com/s

Strona 113 - Layers within Displays

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 2  Enhancements to FactoryTalk Historian ProcessBook Display The Playback toolbar added fo

Strona 114

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 182 3. Click inside the display where you want to start drawing the first point of the poly

Strona 115

5 ● Visualize Data with Symbols ● ● ● ● ● 183 To draw a polyline: 1. In Build mode, open a display. 2. On the Drawing toolbar, click . The mouse

Strona 116 - Layers and Composite Symbols

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 184  Add an illustration to a display, and store it within the display or link it to the o

Strona 117 - Active Layers Status Bar

5 ● Visualize Data with Symbols ● ● ● ● ● 185 Add a Graphic To add a graphic: 1. In Build mode, open a display. 2. On the Drawing toolbar, click

Strona 118 - Historian Server

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 186 4. Click the Browse button to locate the graphic drawing. -or- In the File Name box, ty

Strona 119

5 ● Visualize Data with Symbols ● ● ● ● ● 187 Use a Symbol from the Symbol Library To add a symbol from the Symbol Library to a display: 1. In Bui

Strona 120

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 188 6. Click OK to add the symbol to your display. Symbol Library Options To configure a s

Strona 121 - Visualize Data with Symbols

5 ● Visualize Data with Symbols ● ● ● ● ● 189 Rotation Select 90, 180, or 270 to turn the symbol by 90 degree increments. The default setting is 0

Strona 122 - Create a Trend

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 190

Strona 123

Chapter 6 191 Work with Symbols Details and Annotations The Details docking window is available to show data from dynamic symbols. The window is o

Strona 124

1 ● Introduction ● ● ● ● ● 3  Display navigation is enhanced with browser-based navigation controls (page 16) that traverse, open, and bookmark d

Strona 125

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 192 By default, the window remains open when a different display symbol is selected. The Det

Strona 126

6 ● Work with Symbols ● ● ● ● ● 193 Option This field allows you to toggle among three different types of information about your data source.  D

Strona 127 - Move a Plot

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 194 Copy to Clipboard Allows you to copy the data table to your clipboard. You can then pas

Strona 128 - Define Trend Dialog Box

6 ● Work with Symbols ● ● ● ● ● 195 FactoryTalk Historian Annotations Maintenance Annotations allow you to associate related information (such as t

Strona 129 -  Layout (page 115)

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 196 If you select Show All from the Data Source drop-down box on the Details (page 191) wind

Strona 130 - Display Format Tab

6 ● Work with Symbols ● ● ● ● ● 197 The add-in can be unloaded or set not to load at startup by changing the options in the Add-in Manager (page 13

Strona 131 - Trace Format Tab

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 198 Search for Data Favorites The Search panel provides controls for searching for Factory

Strona 132

6 ● Work with Symbols ● ● ● ● ● 199 FactoryTalk Historian ProcessBook window. When a docking window is unpinned, a button appears along the side of

Strona 133 - Layout Tab

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 200 3. In the Favorites list (page 199), drag and drop any listed favorite to an existing t

Strona 134

6 ● Work with Symbols ● ● ● ● ● 201 Drags can come from any application that supports the text clipboard format, for example, Microsoft Word or Exc

Strona 135 - Configure Trend Scale

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 4

Strona 136 - Trend Analysis Tools

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 202 In Run mode, click View > Revert, or click the Revert button. Change the Time Range

Strona 137 - Trend Zoom 2x In or Out

6 ● Work with Symbols ● ● ● ● ● 203 3. Select new starting and ending times from the drop-down lists or define your own starting and ending times.

Strona 138 - Trend Cursor

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 204 Time Forward and Back Use the time backward and forward buttons to scroll the time rang

Strona 139 - Remove a Trend Cursor

6 ● Work with Symbols ● ● ● ● ● 205 1. In Build mode, open a display. 2. Click a symbol in your display. Small squares appear around the bounding

Strona 140 - How Trends Refresh

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 206  To select several symbols at the same time, click near a symbol, and then drag to cre

Strona 141 - Trend Appearance

6 ● Work with Symbols ● ● ● ● ● 207 Flip a Symbol You can create a mirror image of a symbol by flipping it. You cannot flip text, graphics, or OLE

Strona 142 - Value Scale Grid Lines

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 208 Using the stacking commands, you can move a symbol forward or backward within the stack

Strona 143

6 ● Work with Symbols ● ● ● ● ● 209  Click Send to Back to move it to the bottom of the stack (below everything). Align Multiple Symbols You ca

Strona 144 - Time Scale Grid Lines

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 210 3. Click the alignment options you want. All the selected symbols are aligned to the s

Strona 145 - Hide Traces

6 ● Work with Symbols ● ● ● ● ● 211 Group The symbols combine into one composite symbol with selection handles around the entire group. Ungroup

Strona 146 - Markers

Chapter 2 5 FactoryTalk Historian ProcessBook Essentials What Can You View with FactoryTalk Historian ProcessBook A FactoryTalk Historian ProcessB

Strona 147 - Ad Hoc Trends

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 212 Each end of a Connector attaches to a Connection Point on another symbol. If you have no

Strona 148 - Save an Ad Hoc Trend Display

6 ● Work with Symbols ● ● ● ● ● 213 Connection Points Connection points on each symbol define where a Connector may connect. Connection Points are

Strona 149 - OpenVMS Trends and Graphics

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 214 If a symbol is placed in front of another, the Connection Points on the hidden symbol ca

Strona 150 - Convert Graphics

6 ● Work with Symbols ● ● ● ● ● 215 1. In Build mode, click a connection point. 2. Click Edit > Connection Points > Move. The Connection Po

Strona 151 - XYPlots

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 216 If you are using a symbol from the Symbol Library, the Connection Point is named <TBS

Strona 152

6 ● Work with Symbols ● ● ● ● ● 217 The Flow tab shows two tree diagrams, Source and Destination, where you can change the Connection Points for th

Strona 153

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 218 Configure the Flow Tab To configure the Flow tab: 1. In Build mode, open the Connectors

Strona 154 - Draw an XYPlot

6 ● Work with Symbols ● ● ● ● ● 219 Connectors Dialog Box, Attachments Tab For very complex displays, it may be helpful to attach or arrange Connec

Strona 155 - General Tab

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 220 Configure the Attachments Tab To configure the Attachments tab: 1. In Build mode, creat

Strona 156 - Add or Edit Placeholders

6 ● Work with Symbols ● ● ● ● ● 221 Attach a Symbol as an Adjunct to a Connector Sometimes it is desirable to attach a symbol, such as a flow meter

Strona 157 - Configure Pairings

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 6 Start FactoryTalk Historian ProcessBook To begin using FactoryTalk Historian ProcessBook:

Strona 158 -  Match or Next

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 222 1. Select at least two symbols. This enables the Symbol Attachments icon . 2. Click

Strona 159 - Scale Box

6 ● Work with Symbols ● ● ● ● ● 223 4. Place a check mark for the subordinate symbol or symbols and click OK. 5. Repeat the process for each Mast

Strona 160 - Add a Data Set to an XYPlot

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 224 Reroute a Connector Path When you move a symbol, its Connectors shift automatically to s

Strona 161

6 ● Work with Symbols ● ● ● ● ● 225 Item Definition Use the Item Definition button in either Build or Run mode when you want to see what tags and

Strona 162

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 226 Status Report for Dynamic Symbols The status bar at the bottom of the FactoryTalk Histor

Strona 163 - Plot Format Tab

6 ● Work with Symbols ● ● ● ● ● 227 For troubleshooting purposes, click Message Log to view the SDK Log file. You can save this report as a .csv fi

Strona 164 - Ad Hoc XYPlots

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 228 If you clear the Show Value Attributes check box in your Start Preferences, you do not s

Strona 165 - XYPlot Statistics

Chapter 7 229 Data Streams A data stream is any set of data that you can visualize (page 103). This data includes, and is not limited to, FactoryT

Strona 166

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 230 AF attributes AF Attributes represent data that is associated with an element. They can

Strona 167

7 ● Data Streams ● ● ● ● ● 231 Contextual data Contextual data is a method of associating FactoryTalk Historian points and their properties with th

Strona 168

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 7 A selected check box next to a server name in the Connections dialog box indicates an

Strona 169 - Correlation Coefficient

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 232 On the Standard toolbar, click , or click the Tag Search button in any of the following

Strona 170 - Interpreting an XYPlot

7 ● Data Streams ● ● ● ● ● 233  Alias Search provides a logical tree view of a FactoryTalk Historian server through the FactoryTalk Historian mod

Strona 171 - Zoom/Revert Functions

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 234 You can also click Favorites to access previous searches. 3. Tags returned from a searc

Strona 172

7 ● Data Streams ● ● ● ● ● 235 select each tag from the drop-down list or use the up and down arrows on your keyboard to scroll through the tags. T

Strona 173

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 236 Point Type How It Is Used PB Support Int16 FactoryTalk Historian ProcessBook supports th

Strona 174 - XYPlot Cursors

7 ● Data Streams ● ● ● ● ● 237 Data from a FactoryTalk Historian System Most displays include a number of FactoryTalk Historian tags from one or mo

Strona 175

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 238 Displays are updated whenever values change. Every five seconds, FactoryTalk Historian P

Strona 176 - Examples of XYPlots

7 ● Data Streams ● ● ● ● ● 239 In order to convert a legacy Module Relative Display to an Element Relative Display you must first migrate modules i

Strona 177

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 240 3. Once you select an AF System, search for an AF database using the Databases search b

Strona 178 - Example 3: Lab Comparisons

7 ● Data Streams ● ● ● ● ● 241 Add Element Relative Data to a Dynamic Symbol Use the Select Attributes dialog box to add AF Elements and Attributes

Strona 179

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 8 FactoryTalk Historian Security FactoryTalk Historian ProcessBook is designed to support wh

Strona 180 - Additional Dynamic Symbols

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 242 3. Click Element Relative. The Select Attributes dialog box appears. The active elemen

Strona 181

7 ● Data Streams ● ● ● ● ● 243  UOM - allows you to select a unit of measure for a given attribute. 6. [Optional] Click Add Element Name to add

Strona 182

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 244 How to Change Element Context You can dynamically change the context for the selected el

Strona 183

7 ● Data Streams ● ● ● ● ● 245 1. Click View > Element Relative Display. The Element Relative Display window appears. 2. In the Search Mask t

Strona 184 - Add a Button

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 246 4. Click OK. Any new items are added to the Elements of Interest list in the Element Re

Strona 185

7 ● Data Streams ● ● ● ● ● 247 create an independent display (a .PDI file), the data set is defined only for that display. Trends including data se

Strona 186 - Add a Dynamic Bar

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 248  PI calculation (page 248) data sets (including FactoryTalk Historian expression and F

Strona 187

7 ● Data Streams ● ● ● ● ● 249  FactoryTalk Historian Summary Data Sets FactoryTalk Historian Summary Data Sets enable you to use pre- determined

Strona 188

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 250 These functions are fully described in the Performance Equations chapter of the FactoryT

Strona 189 - Bar Scales

7 ● Data Streams ● ● ● ● ● 251 2. Click New > PI calculation. The PI Calculation Data dialog box appears.

Strona 190 - Tick Marks

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 9 Displays and Connection Failure If the connection to your data is not successful, the

Strona 191

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 252 3. Review the following for additional information: PI Server Select a FactoryTalk Hist

Strona 192 - Multi-State Symbols

7 ● Data Streams ● ● ● ● ● 253  The sync time must be a valid FactoryTalk Historian Time. Your new data set appears in the Data Sets dialog box.

Strona 193

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 254 moving average to show a smoothed version of the same curve. The moving average is built

Strona 194

7 ● Data Streams ● ● ● ● ● 255 column of the results for a display. For example, in a trend, each column in the data set that you select appears as

Strona 195 - Static Symbols

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 256 4. Under Description, type a description if you like. This text is displayed in the Des

Strona 196 - Edit a Text Box

7 ● Data Streams ● ● ● ● ● 257 defined in the order in which they are encountered in the SQL statement. 13. Click Placeholders to check the syntax

Strona 197 - Line Symbol

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 258 The standard SQL placeholder character is (?). Placeholders are numbered in their order

Strona 198

7 ● Data Streams ● ● ● ● ● 259 symbol without affecting the placeholders defined for any other symbol using that data set. Add or Edit Placeholder

Strona 199 - Polygon Symbol

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 260 2. Under Placeholder Name, select the parameter you want to configure. The parameters

Strona 200 - Polyline Symbol

7 ● Data Streams ● ● ● ● ● 261 5. Click Set. 6. To configure another parameter, select it and repeat the previous steps. 7. Click OK. Is a Data

Strona 201 - Graphic Symbol

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 10 Node Identifiers for Multiple FactoryTalk Historian Servers A Node Identifier is stored w

Strona 202

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 262 Add a Data Set to a Trend Just as you would add tags in defining a trend, you can add co

Strona 203 - Add a Graphic

7 ● Data Streams ● ● ● ● ● 263 4. Click the Tag Search arrow, and then click PI calculation. The PI Calculation Data dialog box appears. If you wa

Strona 204 - Symbol Library

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 264 The selected data set/column(s) is now listed under Tags in Plot in the Define Trend dia

Strona 205

7 ● Data Streams ● ● ● ● ● 265 axis with changing FactoryTalk Historian exception data points until the refresh interval expires and new data are r

Strona 206 - Symbol Library Options

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 266 successful connection, FactoryTalk Historian ProcessBook retains this information for us

Strona 207

7 ● Data Streams ● ● ● ● ● 267 3. Click File > Return to ProcBook when you are finished. Microsoft Query cannot edit query statements that cont

Strona 208

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 268 Delete a Data Set Before you can remove a data set from the FactoryTalk Historian Proces

Strona 209 - Chapter 6

7 ● Data Streams ● ● ● ● ● 269 3. From the Tools menu, select Data Sets. The Data Sets (page 246) dialog box appears. 4. Under Data Sets, click t

Strona 210

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 270 To select an AF Attribute: 1. Connect to an AF database. 2. Select an AF Element. 3.

Strona 211 - 6 ● Work with Symbols

7 ● Data Streams ● ● ● ● ● 271 Configure the AF2.x DataSet To configure an AF dataset: 1. Click Tools > Datasets to open the Data Sets dialog b

Strona 212 - Open Details Window

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 11 Display The main unit for creating presentations of data in FactoryTalk Historian Pro

Strona 213

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 272 ODBC Data Sources An ODBC data source identifies a database a user wants to access and

Strona 214 - Data Favorites

7 ● Data Streams ● ● ● ● ● 273 Using ODBC requires that you install the Microsoft ODBC Driver Manager and drivers (most operating systems already h

Strona 215

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 274 3. Click Setup. The Microsoft ODBC Data Source Administrator dialog box appears. Prep

Strona 216 - Search for Data Favorites

7 ● Data Streams ● ● ● ● ● 275 Configure the ODBC Data Source Once any necessary ODBC drivers are installed, you need to configure the ODBC data so

Strona 217 - Favorites Panel

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 276 Assumptions About Timestamps and Data Sets When a trend receives data from an ODBC data

Strona 218

7 ● Data Streams ● ● ● ● ● 277 An ODBC data set is created with a set of default placeholders. When it is attached to a specific symbol, the query&

Strona 219 - Time Range Toolbar

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 278 Initiate Call Tracing To initiate call tracing: 1. Click Tools > Data Sets. The Data

Strona 220 - Change the Time Range

7 ● Data Streams ● ● ● ● ● 279 1. Open the ODBC Data Source Administrator (page 273) dialog box. 2. In the User DSN tab, under User Data Sources,

Strona 221 - Use the Scrolling Time Range

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 280

Strona 222 - Select and Move a Symbol

Chapter 8 281 Embedding and Linking FactoryTalk Historian ProcessBook provides the capability to use OLE linking and embedding (page 283). You can

Strona 223 - Select Multiple Symbols

Contents iii Introduction ... 1 Recent History and Requirements for FactoryTalk Historia

Strona 224 - Rotate a Symbol

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 12 Run Mode and Build Mode When you work with a ProcessBook or an independent display, you

Strona 225 - Stacking Order

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 282  ProcessBook displays may be used to exhibit dynamic data within other container appli

Strona 226

8 ● Embedding and Linking ● ● ● ● ● 283 For more information on how to write Visual Basic scripts for use with FactoryTalk Historian ProcessBook, c

Strona 227 - Align Multiple Symbols

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 284 linked source file. No matter how many links it has, only one version of the linked file

Strona 228

8 ● Embedding and Linking ● ● ● ● ● 285 ActiveX Controls You can insert ActiveX controls that are installed on your PC into FactoryTalk Historian P

Strona 229 - Connect Symbols

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 286 In Run mode, a user could change the month and date. A programmer could incorporate the

Strona 230

8 ● Embedding and Linking ● ● ● ● ● 287 Icons vs. Graphics You may choose to have embedded or linked objects displayed either as graphic representa

Strona 231 - Connection Points

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 288 You must be in Build mode in order to insert a new object. Click Insert > Object to l

Strona 232

8 ● Embedding and Linking ● ● ● ● ● 289 7. Click OK. The object appears on your display. Embed a New File in a Display To embed a new file in a d

Strona 233

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 290 If you open a display and drag an object elsewhere, the display is permanently changed,

Strona 234 - Connectors Dialog Box

8 ● Embedding and Linking ● ● ● ● ● 291 Dynamic and Manual Updates of a Linked Object The default setting for a link is automatic updates, meaning

Strona 235

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 13 Add-Ins By default, FactoryTalk Historian ProcessBook installs with the following add

Strona 236 - Configure the Flow Tab

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 292 How Links Are Stored When you establish a link between a ProcessBook display and a sour

Strona 237

8 ● Embedding and Linking ● ● ● ● ● 293 Commands That Ignore OLE Objects The following commands ignore OLE objects: Command Location Action Select

Strona 238

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 294 Edit the Contents of OLE objects Some source applications permit in-place activation, w

Strona 239

8 ● Embedding and Linking ● ● ● ● ● 295 Edit Contents of OLE Objects To edit contents of OLE objects: 1. Open the display. 2. In Build mode, dou

Strona 240

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 296 You may select to display an icon when you are creating the object by selecting the Disp

Strona 241

8 ● Embedding and Linking ● ● ● ● ● 297 6. To select the icon to use, click Change Icon. The Change Icon dialog box appears. 7. Review the follo

Strona 242 - Reroute a Connector Path

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 298 Although applications with OLE functionality use similar commands, they are not exactly

Strona 243 - Item Definition

8 ● Embedding and Linking ● ● ● ● ● 299 When you activate the dragged contents, the entire original display is drawn, regardless of which objects w

Strona 244

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 300 Historian ProcessBook. To do this, use the Insert Object command in the second applicati

Strona 245 - Status Flags for Data

Chapter 9 301 Visual Basic for Applications in FactoryTalk Historian ProcessBook Rockwell Automation licenses Visual Basic for Applications (VBA)

Strona 246

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 14 2. Click an available add-in from the Available Add-Ins list. 3. A description of what

Strona 247 - Data Streams

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 302 Design Mode Stops any scripts that may be running or may start running. Useful for deb

Strona 248

9 ● Visual Basic for Applications in FactoryTalk Historian ProcessBook ● ● ● ● ● 303  Update a FactoryTalk Historian ProcessBook display by typin

Strona 249 - 7 ● Data Streams

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 304

Strona 250

Chapter 10 305 Installation A self-extracting zip file is supplied as the distribution kit for FactoryTalk Historian ProcessBook. To install Facto

Strona 251

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 306  The default install location for Rockwell Software 32-bit applications: C:\Program Fi

Strona 252 - View Point Attributes

10 ● Installation ● ● ● ● ● 307 If you have FactoryTalk Historian BatchView installed on your system, Setup installs a FactoryTalk Historian Proces

Strona 253

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 308 Setup also installs online help files and Release Notes. See the Release Notes for a com

Strona 254

Chapter 11 309 System Administrator Notes High Availability Configuration Settings On workstations where FactoryTalk Historian ProcessBook is used

Strona 255

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 310 primary server continue to function. If the use of ProcessBook on a workstation requires

Strona 256

11 ● System Administrator Notes ● ● ● ● ● 311 Dynamic symbols on the display are presented in the same manner as any other symbol attached to a dis

Strona 257 - Connect to an AF Database

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 15 Menu Bar Function Book Displays when a FactoryTalk Historian ProcessBook workbook is

Strona 258 - Element Search

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 312 does not support FactoryTalk Historian AF data and is discontinued in FactoryTalk Histor

Strona 259

11 ● System Administrator Notes ● ● ● ● ● 313  After you upgrade a FactoryTalk Historian ProcessBook display from MRD to ERD, the display will on

Strona 260

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 314 Read/Write Data Access for Users Although most data features in FactoryTalk Historian Pr

Strona 261 - Context Path

11 ● System Administrator Notes ● ● ● ● ● 315 CLIENTACCESS DEFAULT=R BRIAN=RW The preceding entry allows the PINet node BRIAN to read and to write

Strona 262

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 316 ProcessBook Preferences dialog box for the first time. The values in C:\Documents and Se

Strona 263

11 ● System Administrator Notes ● ● ● ● ● 317 International Date Format Specifies date/time format.  1=Windows format.  0=FactoryTalk Historian

Strona 264 - Data Sets

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 318 MacroProtectionLevel Specifies how ProcessBook handles macros per display. Possible sett

Strona 265

11 ● System Administrator Notes ● ● ● ● ● 319 URL Home Specifies the website navigated to when a user clicks the ProcessBook icon in the Help\About

Strona 266 - PI Calculation Data Sets

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 320 PB2TraceCompatibility Indicates whether all snapshot values are retained for trend trace

Strona 267

11 ● System Administrator Notes ● ● ● ● ● 321 International Date Format=1 MaxUndoStackSize=20 Build Scroll Mode=1 Run Scroll Mode=1 GridSize=12 Fil

Strona 268

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 16 You can configure toolbars to display as view-only to omit unnecessary buttons. View-only

Strona 269

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 322 PitchAndFamily=0 FaceName=Arial The FaceName should be a True-Type font so that it can b

Strona 270 - Tag Search

11 ● System Administrator Notes ● ● ● ● ● 323 Trend Definition Section Trend initializations. Possible entries: Autoscale  1=yes  0=no Value/D

Strona 271 - Intervals and Time Value

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 324 Element These 16 entries are the main drawn properties of trends. For each of 16 trend

Strona 272 - ODBC Data Sets

11 ● System Administrator Notes ● ● ● ● ● 325 Trend Definition Example [Trend Definition] Autoscale=1 Value=1 Description=0 Markers=0 Plot Title=1

Strona 273 - Create an ODBC Data Set

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 326 Colors Section Defines the 16 colors in the ProcessBook palette. Parameters: ColorX = Re

Strona 274

11 ● System Administrator Notes ● ● ● ● ● 327 ThumbScrollNonlinearity Sets the factor by which clicking and holding the thumbwheel of the scrollba

Strona 275 - Placeholders

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 328 Italic=0 PitchAndFamily=34 Display Colors Section Possible entries: DisplayBackgroundCo

Strona 276 - Design Placeholder Queries

11 ● System Administrator Notes ● ● ● ● ● 329 Background Null  1=sets to have no background color.  0=have background color specified under Ele

Strona 277

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 330 Element These 17 entries are the main drawn properties of XYPlots. For each of 17 XYPlo

Strona 278

11 ● System Administrator Notes ● ● ● ● ● 331 MacroProtectionLevel may be set in the [STARTUP] section of Procbook.ini at one of the following leve

Strona 279 - Data Set Details

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 17 3. From the Browser toolbar (page 16), click either the Forward or Back buttons to

Strona 280 - Add a Data Set to a Trend

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 332 IMPPIGP.INI The IMPPIGP.INI file contains configuration settings used by the Import util

Strona 281

11 ● System Administrator Notes ● ● ● ● ● 333 White=255,255,255 Red=255,0,0 Green=0,255,0 Blue=0,0,255 Cyan=0,255,255 Magenta=255,0,255 Yellow=255,

Strona 282

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 334 3 = dash dot 4 = dash dot dot 5 = suppress Font Section The Font section maps the VAX s

Strona 283 - Data Sets Are Included

11 ● System Administrator Notes ● ● ● ● ● 335 Marker Section The Marker section of the .INI file maps the VAX trend markers to the markers provide

Strona 284 - Edit a Data Set

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 336 Keywords for supported terminals are shown below. The horizontal and vertical dimensions

Strona 285

Chapter 12 337 Supplemental Information FactoryTalk Historian Time FactoryTalk Historian Time abbreviations and FactoryTalk Historian Time express

Strona 286 - Delete a Data Set

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 338 PI Times can also be expressed using certain constants: Constant Result * The current ti

Strona 287 - Loading Custom Data Sets

12 ● Supplemental Information ● ● ● ● ● 339  Use absolute or combined time expressions. Avoid using relative time expressions. Multiple relative

Strona 288

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 340 PI Time String Meaning *-1h One hour ago t+8h 8:00:00 am today y-8h 4:00:00 pm on the da

Strona 289 - ODBC Drivers

12 ● Supplemental Information ● ● ● ● ● 341 on the Regional Settings on the computer where FactoryTalk Historian ProcessBook is installed. Format V

Strona 290 - ODBC Data Access

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 18 1. On the Browser toolbar (page 16), click the small arrow next to the Home button . 2.

Strona 291

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 342 Attribute Explanation typicalvalue Typical value. Units Engineering unit string. Zero Ze

Strona 292 - Prepare for ODBC

12 ● Supplemental Information ● ● ● ● ● 343 Attribute Explanation convers Conversion factor for postprocessed points. displaydigits Controls the fo

Strona 293

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 344  An ODBC database might have been restructured, invalidating your dataset. Trend Curs

Strona 294 - Stored Procedures in Queries

12 ● Supplemental Information ● ● ● ● ● 345  At least one of the Y tag end times is indicated as the current time (by using *) or is in the futur

Strona 295 - Trace ODBC Calls

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 346  If the Edit > Links choice is unavailable, the link is permanently broken and your

Strona 296 - Delete an ODBC Data Source

12 ● Supplemental Information ● ● ● ● ● 347 To resolve the problem, re-define the data source. The following figure shows what happens when a Trend

Strona 297 - Edit an ODBC Data Source

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 348

Strona 298

Chapter 13 349 Technical Support and Resources Rockwell provides dedicated technical support internationally, 24 hours a day, 7 days a week. You c

Strona 299 - Embedding and Linking

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 350 Worldwide Support If you are not located in North America and want to contact Rockwell

Strona 300 - ProcessBook

13 ● Technical Support and Resources ● ● ● ● ● 351 When you contact Rockwell Technical Support, please provide:  Product name, version, and/or bu

Strona 301 - Object Linking and Embedding

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 19 Bookmarks New bookmarks are automatically added to the root level of the bookmarks t

Strona 302 - Should You Link or Embed?

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 352 directory and type the subsystem name followed by the option -v (for example, piarchss.e

Strona 303 - ActiveX Controls

Index 353 Index 6 64-bit Operating Systems • 305 A About FactoryTalk Historian Data • 229 About FactoryTalk Historian ProcessBook • 36 Active L

Strona 304 - ProcessBook Display

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 354 Change the Display Range • 93 Change the Language Used for FactoryTalk Historian Process

Strona 305 - Icons vs. Graphics

● Index ● ● ● ● ● 355 Delete Connection Points • 214 DEP Security • 313 Design Placeholder Queries • 258 Details and Annotations • 191 Details Wind

Strona 306

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 356 F FactoryTalk Historian Annotations Maintenance • 195 FactoryTalk Historian Data Archive

Strona 307 - Windows Drag and Drop

● Index ● ● ● ● ● 357 Layers within Displays • 95 Layout Tab • 115 Line Color • 82 Line Ends • 86 Line Style • 85 Line Style Section • 333 Line Sym

Strona 308 - Link a File to a Display

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 358 Open Independent Display Files • 71 Open Several Displays at One Time • 70 OpenVMS Trend

Strona 309 - Edit, Update, or Break Links

● Index ● ● ● ● ● 359 Select Among Multiple Connection Points on One Symbol • 214 Select and Move a Symbol • 204 Select Multiple Symbols • 205 Serv

Strona 310 - Select a New Source Link

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 360 Use MSQuery to Build Data Sets • 275 Use the Scrolling Time Range • 203 V Value Scale Gr

Strona 311 - OLE Object Colors

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 20 3. Click to edit a bookmark. If the active file is already bookmarked, the same icon a

Strona 312

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 21 Assign a Keyboard Shortcut To assign a keyboard shortcut: 1. Click View > Assign

Strona 313 - Edit Contents of OLE Objects

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide iv Command Menus ... 14 Customize

Strona 314 - Convert Objects to Icons

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 22 4. Under Press new shortcut key, type the key you wish to use for the shortcut. If you c

Strona 315 - Applications

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 23 Preference settings are stored in the file procbook.ini. Before you change the Prefer

Strona 316 - Application

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 24 Review the following for additional information: Author Determines the name used as the

Strona 317 - OLE Container/Server

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 25 Date and Time Format Settings in this area determine how time is displayed in Factory

Strona 318

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 26 Table of Contents Preferences Click Tools > Preferences > Table of Contents tab to

Strona 319 - Chapter 9

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 27 Review the following for additional information: Default View Settings in this area d

Strona 320 - ActiveX Automation

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 28 Display Window Click Tools > Preferences > Display Window tab to set options that a

Strona 321 - Automation Vocabulary

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 29 Review the following for additional information: Preserve Aspect Ratio on resize Dete

Strona 322

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 30 Trend Preferences Click Tools > Preferences > Trend tab to set default settings for

Strona 323 - Installation

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 31 Review the following for additional information: Display Check or clear these options

Strona 324 - Products

● Contents ● ● ● ● ● v Create a Text or Display Entry ... 43 Linked Display Entry ...

Strona 325 - Installed Files

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 32 Sample Use this display area to view a preview of selected trend preferences. Trend Ele

Strona 326

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 33 Review the following for additional information: Multi-State on Ad Hoc Select this ch

Strona 327 - System Administrator Notes

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 34 Each topic in the help file may be printed separately or you can print them all at once.

Strona 328

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 35 Print Preview Print Preview displays your selection as it will look when it is print

Strona 329 - MDB to AF Migration

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 36 Change the Language Used for FactoryTalk Historian ProcessBook You can change the languag

Strona 330

2 ● FactoryTalk Historian ProcessBook Essentials ● ● ● ● ● 37  Click Copy Info to copy the contents of the list to your Windows clipboard where i

Strona 331 - DEP Security

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 38

Strona 332

Chapter 3 39 Work with a ProcessBook Basic Steps to Build a ProcessBook There are five basic steps to creating a ProcessBook (page 39): 1. Create

Strona 333 - PROCBOOK.INI

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 40 When you create and save a new ProcessBook, the application initially gives it the title

Strona 334 - Startup Section

3 ● Work with a ProcessBook ● ● ● ● ● 41 Depending on the settings in the ProcessBook Preferences dialog box, a default ProcessBook may open automa

Strona 335

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide vi Work with a Display ... 67 Overview of Dis

Strona 336

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 42  Linked ProcessBook (page 46) - links to an entry in another ProcessBook.  Operating

Strona 337

3 ● Work with a ProcessBook ● ● ● ● ● 43 Create a Text or Display Entry Use text entries to add labels and clarify text in a ProcessBook table of c

Strona 338 - Startup Example

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 44 The linked entry is not a copy; it is a way of opening the original, similar to using a W

Strona 339 - ProcessBook View Section

3 ● Work with a ProcessBook ● ● ● ● ● 45 6. Click the Browse button, or click the Browse arrow to see more search options. The Open dialog box app

Strona 340 - Data Manager Section

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 46 If you need to move the original entry to another directory or ProcessBook, you must rede

Strona 341 - Trend Definition Section

3 ● Work with a ProcessBook ● ● ● ● ● 47 When you have reports created on a different system, you can convert them to ASCII and, using an operating

Strona 342

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 48 8. If you need to specify the location of the executable for the application, click the

Strona 343 - Trend Definition Example

3 ● Work with a ProcessBook ● ● ● ● ● 49 If you need to move the original entry to another directory or ProcessBook, you must redefine the link bet

Strona 344 - Time Range Scroll Section

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 50 Whether you are in Outline View or Book View, you can edit and rearrange entries, or dele

Strona 345 - ProcessBook Level Section

3 ● Work with a ProcessBook ● ● ● ● ● 51 summary display. Each of these displays can have several displays for their components. Turn Pages in Bo

Strona 346 - XYPlot Definition Section

● Contents ● ● ● ● ● vii Editable Formatting Attributes ... 81 Font ...

Strona 347

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 52 2. Click the upper triangle to move forward one page, or click the lower triangle to mov

Strona 348 - Macro Protection

3 ● Work with a ProcessBook ● ● ● ● ● 53 Change the Name of an Entry in Book View To change the name of an entry in the Book view: 1. Click View &

Strona 349 - View Only Mode

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 54 Hierarchies of entries may be revised by dragging entries from one location to another, o

Strona 350 - IMPPIGP.INI

3 ● Work with a ProcessBook ● ● ● ● ● 55 1. Click View > Outline to view a ProcessBook in Outline View (page 53). 2. Click the black plus sign

Strona 351 - Line Style Section

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 56 Move the highlighted entry down. Change the Name of an Entry in Outline View To change

Strona 352 - Font Section

3 ● Work with a ProcessBook ● ● ● ● ● 57 Copy and Paste an Entry To copy and paste an entry: 1. Click the Build mode pointer and select the entry.

Strona 353 - Display Section

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 58 Save and Close a ProcessBook After creating a ProcessBook, it is a good idea to name the

Strona 354 - SETUPProcessBook.LOG

3 ● Work with a ProcessBook ● ● ● ● ● 59 Properties Summary Information in ProcessBook Click File > Properties to display the Summary Informatio

Strona 355 - Supplemental Information

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 60 Field Name Description Keywords May be added at any time. Comments May be used for any te

Strona 356

3 ● Work with a ProcessBook ● ● ● ● ● 61 Field Name Description Title Extracted from the Summary Information dialog box. Created Original date and

Strona 357 - Time Syntax Examples

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide viii Create a Trend ... 104 Build

Strona 358 - Table of Format Values

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 62 ProcessBook window displays the file name, which ends in .piw, rather than the title. 3.

Strona 359 - ProcessBook is installed

3 ● Work with a ProcessBook ● ● ● ● ● 63 Field Name Description the original date and time will be preserved, however Windows Explorer shows the da

Strona 360

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 64 3. Select the file type. 4. Select the drive and directory where the file resides, or t

Strona 361 - Troubleshooting Tips

3 ● Work with a ProcessBook ● ● ● ● ● 65 -or-  Close the ProcessBook and reopen it so that the new version of the display is shown. Then make cha

Strona 362 - Is an XYPlot Updating?

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 66

Strona 363 - Embedded?

Chapter 4 67 Work with a Display FactoryTalk Historian ProcessBook provides tools for manipulating and analyzing the information shown in a displa

Strona 364 - ODBC Problems

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 68 Dynamic Symbols Dynamic symbols are values, bars, trends, XYPlots, SQC charts, and multi-

Strona 365

4 ● Work with a Display ● ● ● ● ● 69 Manage Displays and Independent Display Files Open a Display Use any of these procedures to open a display fr

Strona 366

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 70 If you click an Operating System Command more than once in the same session, it may run t

Strona 367 - Chapter 13

4 ● Work with a Display ● ● ● ● ● 71 Open Independent Display Files Independent Display Files use a .pdi extension in the file name. When you doubl

Strona 368 - TechConnect Support

● Contents ● ● ● ● ● ix XYPlots ... 133 Draw an XYPlot ...

Strona 369

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 72 the display resize and take up the entire window. OLE objects are not included. 4. Click

Strona 370

4 ● Work with a Display ● ● ● ● ● 73 Search for a Display To search for a display: 1. Open the ProcessBooks (page 40) you want to search. 2. Clic

Strona 371

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 74 Reduce a Display to an Icon to Save Space If you find your work area cluttered with many

Strona 372

4 ● Work with a Display ● ● ● ● ● 75 Display Settings To edit display properties, click Edit > Display, or double-click the Time Zone setting in

Strona 373

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 76 Time Zone This field determines whether the local computer or FactoryTalk Historian serve

Strona 374

4 ● Work with a Display ● ● ● ● ● 77 Run Mode Determines the scroll bar behavior of display windows in Run mode. Build Mode Determines the scroll b

Strona 375

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 78 You can use the drawing tools to:  Create ellipses, polygons, rectangles, arcs, lines,

Strona 376

4 ● Work with a Display ● ● ● ● ● 79 each other. You can move and resize drawing objects. You can also divide a display into layers so that you can

Strona 377

● ● ● ● ● FactoryTalk Historian ProcessBook User Guide 80 While you are drawing, you can use the zoom feature to zoom in on an area that requires m

Strona 378

4 ● Work with a Display ● ● ● ● ● 81 5. Click OK. Formatting Each symbol you draw and place on a display has attributes that determine how the sy