Chapter 3 Collecting Performance Data
5. Click New.
The Configure Performance Parameter Event dialog box
appears.
To configure the event value:
1. In the left pane of the dialog box, click Event Value.
2. In the Event Value Type list, select one of the following:
Collect Value at the Start of the Event
Collect Value at the End of the Event
Collect Value at the Start and the End of the Event
Accumulate Value for the Duration of the Event
None
TIP
For information on individual event value types, see
"Event Value Types (page 101)".
The following steps will differ depending on the event value
type that you have selected.
If you have selected any of these event value types:
Collect Value at the Start of the Event
Collect Value at the End of the Event
Collect Value at the Start and the End of the Event
Accumulate Value for the Duration of the Event
Choose either of the following:
Select a data point for the Event Value
1. Under Data Point, click Select.
The Select Data Point dialog box appears.
100 Rockwell Automation Publication PLTMT-UM001M-EN-P-June 2014