Rockwell Automation Publication IASIMP-QS030A-EN-P - July 2012 35
Create DeviceNet Network Software Files Chapter 2
Create a DeviceNet Scanlist
1. Verify that your RSLogix 5000 project that is used with this quick start is open and online.
2. In your RSLogix 5000 project,
right-click the scanner module and
choose properties.
3. On the RSNetWorx tab, click the
Launch RSNetWorx for
DeviceNet icon.
If the project is not associated with
the configuration file, use the
Browse function to associate them
with each other.
4. Click the Launch RSNetWorx for
DeviceNet icon.
The RSNetWorx for DeviceNet launches and opens the DeviceNet configuration file
associated with your RSLogix 5000 project.
5. From the Network menu,
choose Online.
6. If prompted to upload or
download device information,
click OK.
Przeglądanie stron 34