Add the PowerFlex 40 Drive to an RSLogix 5000 Project Chapter 2
The software shows a Creating
Device Database File dialog box
that tracks the progress of the
function.
No action is necessary.
11. Click OK when the dialog box
appears alerting you that the match
to the online drive was successful.
12. Click OK on the Module
Definition dialog box to return the New Module dialog box.
13. Click the Connection tab.
14. Clear Use Unicast Connection
over EtherNet/IP and Click OK.
15. Click Close on the Select Module
Type dialog box.
16. Save the project.
The 22B-V2P3N104 drive is added to
the controller organizer.
IMPORTANT
If your computer already has a
database on it, the software
will not create a new one.