10 POINT I/O 120/220V AC Output Module
Publication 1734-IN009E-EN-E - March 2013
1. Using a bladed screwdriver, rotate the keyswitch on the mounting base clockwise
until the number required for the type of module being installed aligns with the
notch in the base.
2. Make certain the DIN rail locking screw is in the horizontal position. You cannot
insert the module if the locking mechanism is unlocked.
Turn the keyswitch to align
the number with the notch.
Notch position 1 is shown.
Make sure the DIN-rail
locking screw is in the
horizontal position.
1734-TOP Base
45697