Installation Instructions
GuardPLC Digital Output Module
Catalog Number 1753-OB16
Topic Page
Important User Information 2
About the Module 3
General Safety 3
Install the Module 4
Mount the Module 5
Ground the Module 5
Wire the Module 6
Make Connections for Safety-Related
Communication
9
Reset Push Button 9
Status Indicators 10
Specifications 11
Additional Resources 14
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Installation Instructions

Installation InstructionsGuardPLC Digital Output ModuleCatalog Number 1753-OB16Topic PageImportant User Information 2About the Module 3General Safety

Strona 2 - Important User Information

10 GuardPLC Digital Output ModuleRockwell Automation Publication 1753-IN005B-EN-P - June 2010Status IndicatorsIndicator State Condition24V DC On 2

Strona 3 - General Safety

GuardPLC Digital Output Module 11Rockwell Automation Publication 1753-IN005B-EN-P - June 2010SpecificationsTechnical Specifications – 1753-OB16 Mo

Strona 4 - Install the Module

12 GuardPLC Digital Output ModuleRockwell Automation Publication 1753-IN005B-EN-P - June 2010Current per group (admissible total current)8 A max (

Strona 5 - Ground the Module

GuardPLC Digital Output Module 13Rockwell Automation Publication 1753-IN005B-EN-P - June 2010EFT/B Immunity• IEC 61000-4-4• ±2 kV @ 5 kHz on DC po

Strona 6 - Wire the Module

14 GuardPLC Digital Output ModuleRockwell Automation Publication 1753-IN005B-EN-P - June 2010Additional ResourcesThe table below provides a listin

Strona 7 - Digital Output Terminals

GuardPLC Digital Output Module 15Rockwell Automation Publication 1753-IN005B-EN-P - June 2010

Strona 8

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400Rockwell Automation Publication 17

Strona 9 - Reset Push Button

2 GuardPLC Digital Output ModuleRockwell Automation Publication 1753-IN005B-EN-P - June 2010Important User InformationSolid-state equipment has op

Strona 10 - Status Indicators

GuardPLC Digital Output Module 3Rockwell Automation Publication 1753-IN005B-EN-P - June 2010About the ModuleThe 1753-OB16 digital output module is

Strona 11 - Specifications

4 GuardPLC Digital Output ModuleRockwell Automation Publication 1753-IN005B-EN-P - June 2010Environment and EnclosureInstall the ModuleFollow thes

Strona 12

GuardPLC Digital Output Module 5Rockwell Automation Publication 1753-IN005B-EN-P - June 2010Mount the ModuleThe module cannot be panel-mounted. Mo

Strona 13 - Certifications

6 GuardPLC Digital Output ModuleRockwell Automation Publication 1753-IN005B-EN-P - June 2010Wire the ModuleThe following sections describe how to

Strona 14 - Additional Resources

GuardPLC Digital Output Module 7Rockwell Automation Publication 1753-IN005B-EN-P - June 2010Safety-related Digital OutputsThe module has 16 digita

Strona 15

8 GuardPLC Digital Output ModuleRockwell Automation Publication 1753-IN005B-EN-P - June 2010For connection of a load, the reference pole L- of the

Strona 16 - Rockwell Automation Support

GuardPLC Digital Output Module 9Rockwell Automation Publication 1753-IN005B-EN-P - June 2010Make Connections for Safety-Related CommunicationThe m

Komentarze do niniejszej Instrukcji

Brak uwag