Podsumowanie treści

Strona 1 - User Manual

EtherNet/IP Secure CommunicationCatalog Number 1756-EN2TSCUser Manual

Strona 2 - Important User Information

10 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 1 Secure Communication ArchitectureThe 1756-EN2TSC module provides a level

Strona 3 - Information

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 11Secure Communication Architecture Chapter 1Local Chassis SecurityYou can use the 1

Strona 4

12 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 1 Secure Communication ArchitectureThe trusted slot and serial number lock

Strona 5 - Table of Contents

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 13Secure Communication Architecture Chapter 1As part of establishing the secure tunn

Strona 6

14 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 1 Secure Communication ArchitecturePerformanceThe basic communication capa

Strona 7 - Additional Resources

Rockwell Automation Publication ENET-UM003B-EN-P - August 2013 15Chapter 2Get StartedThis chapter describes the initial configuration settings require

Strona 8

16 Rockwell Automation Publication ENET-UM003B-EN-P - August 2013Chapter 2 Get StartedConfigure all security parameters via the web server. In the Add

Strona 9 - Chapter 1

Rockwell Automation Publication ENET-UM003B-EN-P - August 2013 17Get Started Chapter 22. After the web browser connects to the server, a warning messa

Strona 10 - Considerations

18 Rockwell Automation Publication ENET-UM003B-EN-P - August 2013Chapter 2 Get StartedDefault CredentialsDefault credentials are case sensitive and ar

Strona 11 - Local Chassis Security

Rockwell Automation Publication ENET-UM003B-EN-P - August 2013 19Get Started Chapter 2See the next chapters in this manual for different security conf

Strona 12 - Network Access Security

Important User InformationRead this document and the documents listed in the additional resources section about installation, configuration, and opera

Strona 13 - IPsec Association

20 Rockwell Automation Publication ENET-UM003B-EN-P - August 2013Chapter 2 Get StartedIn This Field SpecifyEthernet Interface Configuration The networ

Strona 14 - Performance

Rockwell Automation Publication ENET-UM003B-EN-P - August 2013 21Get Started Chapter 2Create User AccountsYou can define user accounts for the web int

Strona 15 - Get Started

22 Rockwell Automation Publication ENET-UM003B-EN-P - August 2013Chapter 2 Get StartedFrom this form, you can change the following:• Password• Group m

Strona 16 - Initial Powerup

Rockwell Automation Publication ENET-UM003B-EN-P - August 2013 23Get Started Chapter 2Some web pages use both .asp, form, and URL elements. In such ca

Strona 17 - Get Started Chapter 2

24 Rockwell Automation Publication ENET-UM003B-EN-P - August 2013Chapter 2 Get StartedCertificatesOn initial powerup, the subject common name (CN) of

Strona 18 - Configuration Overview

Rockwell Automation Publication ENET-UM003B-EN-P - August 2013 25Get Started Chapter 2Backup / RestoreTo back up module configuration, choose Administ

Strona 19 - Assign Network Settings

26 Rockwell Automation Publication ENET-UM003B-EN-P - August 2013Chapter 2 Get Started1. Specify the back-up file to use.2. If the back-up file is pas

Strona 20

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 27Chapter 3Configure a Secure Connection to a Microsoft Windows ClientIn this scenar

Strona 21 - Create User Accounts

28 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 3 Configure a Secure Connection to a Microsoft Windows ClientTo configure

Strona 22 - Edit Access Limits

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 29Configure a Secure Connection to a Microsoft Windows Client Chapter 3The Microsoft

Strona 23 - Generate HTTPS Certificate

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 3Summary of ChangesThis manual contains new and updated information. Changes through

Strona 24 - Certificates

30 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 3 Configure a Secure Connection to a Microsoft Windows Client1. Log in to

Strona 25 - Backup / Restore

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 31Configure a Secure Connection to a Microsoft Windows Client Chapter 34. Click Add.

Strona 26 - Chapter 2 Get Started

32 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 3 Configure a Secure Connection to a Microsoft Windows Client8. Make the f

Strona 27 - Windows Client

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 33Configure a Secure Connection to a Microsoft Windows Client Chapter 311. If needed

Strona 28 - L2TP Connections

34 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 3 Configure a Secure Connection to a Microsoft Windows Client15. Click Add

Strona 29 - Configure a Mobile Client

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 35Configure a Secure Connection to a Microsoft Windows Client Chapter 34. Select No,

Strona 30

36 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 3 Configure a Secure Connection to a Microsoft Windows Client7. Enter the

Strona 31 - Clients

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 37Configure a Secure Connection to a Microsoft Windows Client Chapter 312. Once the

Strona 32

38 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 3 Configure a Secure Connection to a Microsoft Windows Client15. On the Op

Strona 33

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 39Configure a Secure Connection to a Microsoft Windows Client Chapter 316. On the Se

Strona 34 - Microsoft Windows Client

4 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Summary of ChangesNotes:

Strona 35

40 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 3 Configure a Secure Connection to a Microsoft Windows Client18. On the Ne

Strona 36

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 41Configure a Secure Connection to a Microsoft Windows Client Chapter 3Interface Met

Strona 37

42 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 3 Configure a Secure Connection to a Microsoft Windows ClientOpen the VPN

Strona 38

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 43Configure a Secure Connection to a Microsoft Windows Client Chapter 3Communicate t

Strona 39

44 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 3 Configure a Secure Connection to a Microsoft Windows ClientIf you connec

Strona 40

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 45Chapter 4Configure Secure Communication Between Two 1756-EN2TSC ModulesIn this sce

Strona 41 - Interface Metric

46 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 4 Configure Secure Communication Between Two 1756-EN2TSC ModulesTo create

Strona 42 - Open the VPN Connection to

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 47Configure Secure Communication Between Two 1756-EN2TSC Modules Chapter 4Configure

Strona 43 - Communicate to the Module

48 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 4 Configure Secure Communication Between Two 1756-EN2TSC ModulesConfigure

Strona 44

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 49Configure Secure Communication Between Two 1756-EN2TSC Modules Chapter 4Test the C

Strona 45 - 1756-EN2TSC Modules

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 5Table of ContentsPrefaceAdditional Resources . . . . . . . . . . . . . . . . . . .

Strona 46

50 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 4 Configure Secure Communication Between Two 1756-EN2TSC ModulesNotes:

Strona 47 - Configure the First (Local)

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 51Chapter 5Configure a Secure Connection to a VPN ApplianceIn this scenario, a VPN a

Strona 48 - (Remote) Module

52 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 5 Configure a Secure Connection to a VPN ApplianceAn appliance like the Ci

Strona 49 - Edit the Security Association

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 53Configure a Secure Connection to a VPN Appliance Chapter 5Configure the Module to

Strona 50

54 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 5 Configure a Secure Connection to a VPN Appliance4. Click Apply Changes.E

Strona 51 - Appliance

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 55Configure a Secure Connection to a VPN Appliance Chapter 5Set the key life time (1

Strona 52 - SSL VPN

56 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 5 Configure a Secure Connection to a VPN ApplianceNotes:

Strona 53 - Connect to a VPN Appliance

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 57Chapter 6DiagnosticsDiagnostic Web PagesThe 1756-EN2TSC module supports the same d

Strona 54

58 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 6 DiagnosticsSecure Tunnel Diagnostics Web PageFor specific diagnostics re

Strona 55

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 59Diagnostics Chapter 6Status IndicatorsThe 1756-EN2TSC module uses the same status

Strona 56

6 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Table of ContentsDiagnosticsDiagnostic Web Pages . . . . . . . . . . . . . . . . .

Strona 57 - Diagnostics

60 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013Chapter 6 DiagnosticsNetwork (NET) Status IndicatorOK Status IndicatorStatus Descr

Strona 58 - Web Page

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 61IndexAaccess limits 22additional resources 7, 15architectureMicrosoft Windows clie

Strona 59 - Status Indicators

62 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013IndexTtest connection 49traffic filtering 14trusted slot 11Uuser account 21VVPM ap

Strona 61

Publication ENET-UM003B-EN-P - September 2013Supersedes ENET-UM003A-EN-P - February 2013 Copyright © 2013 Rockwell Automation, Inc. All rights reserve

Strona 62

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 7PrefaceThe 1756-EN2TSC is a security-enhanced version of the 1756-EN2T EtherNet/IP

Strona 63

8 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013PrefaceNotes:

Strona 64 - Documentation Feedback

Rockwell Automation Publication ENET-UM003B-EN-P - September 2013 9Chapter 1Secure Communication ArchitectureMany control systems currently use 1756-E

Komentarze do niniejszej Instrukcji