Rockwell-automation 1756-EN2TSC EtherNet/IP Secure Communication User Instrukcja Użytkownika Strona 48

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 64
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 47
48 Rockwell Automation Publication ENET-UM003B-EN-P - September 2013
Chapter 4 Configure Secure Communication Between Two 1756-EN2TSC Modules
Configure the Second
(Remote) Module
1. Choose Administrative Settings > Secure Tunnel Configuration > IPsec
Configuration and make sure that Enable IPsec is enabled.
2. To create a new secure association, do the following.
a. Enter the Identifier as a text description of the connection.
b. Choose the Peer to Peer as the Profile.
c. Enter the IP address of the first (local) module.
d. Enter the pre-shared key and confirm the pre-shared key.
3. Click Add.
4. Click Apply Changes after entering all configurations.
Przeglądanie stron 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 63 64

Komentarze do niniejszej Instrukcji

Brak uwag