Using
Application Specific Instructions
11–25
Rung 4:3
➀➁
Is identical to the 2 previous rungs except that it is only active
when the ”hole selector switch” is in the ”7-hole” position.
| hole |hole 7 hole |
| selector |selector preset |
| switch |switch sequencer |
| bit 0 |bit 1 |
| I:0 I:0 +SQO–––––––––––––––+ |
|––––] [––––––––] [––––––––––––––––––––+–+SEQUENCER OUTPUT +–(EN)–+–|
| 9 10 | |File #N7:62+–(DN) | |
| | |Mask FFFF| | |
| | |Dest N7:7| | |
| | |Control R6:6| | |
| | |Length 9| | |
| | |Position 0| | |
| | +––––––––––––––––––+ | |
| | force the | |
| | sequencer | |
| | to increment | |
| | on the next | |
| | scan | |
| | R6:6 | |
| +––––(U)––––––––––––––––––––+ |
| EN |
This
rung accesses I/O only available with 32 I/O controllers. Do not include this rung if you are using a 16 I/O
controller.
More rungs will be added to this subroutine at the end of chapter 12.