Installation Instructions
FLEX I/O Isolated Output HART Analog Module
Catalog Number 1794-OF8IH
Topic Page
Important User Information 2
Environment and Enclosure 3
Preventing Electrostatic Discharge 4
North American Hazardous Location Approval 5
Install the Module 7
Wire the Module 8
Ground the Module 10
Module Wiring 11
Cyclic HART Input Data 19
Status Indicator 23
Specifications 23
IMPORTANT
This module can only be used with 1794-ACN(R)15 with version 5.1 (or
greater) firmware, or 1794-AENT with version 4.2 (or greater) firmware. The
1794-AENT currently ships with version 4.1 firmware.
For more information about using this module with 1794-ACN(R)15 with
version 5.1 (or greater) firmware,, see 1794-RN071
.
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - Installation Instructions

Installation InstructionsFLEX I/O Isolated Output HART Analog ModuleCatalog Number 1794-OF8IH Topic PageImportant User Information 2Environment and En

Strona 2 - Important User Information

10 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009Ground the ModuleAll I/O wiring must use shielded wire. Shi

Strona 3

FLEX I/O Isolated Output HART Analog Module 11Publication 1794-IN120C-EN-P - April 2009Module Wiring

Strona 4

12 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 20094 Current O4 A-8Current O4 Ret A-95 Current O5 A-10Current

Strona 5

FLEX I/O Isolated Output HART Analog Module 13Publication 1794-IN120C-EN-P - April 2009(1)This alarm is disabled in Analog 0…20 mA formats (Format

Strona 6

14 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009Configuration MapWord Bit15 14 13 12 11 10 9 8 7 6 5 4 3 2

Strona 7 -

FLEX I/O Isolated Output HART Analog Module 15Publication 1794-IN120C-EN-P - April 200916 Channel 7 Analog Fault Value Output Data17 Reserved C7C6

Strona 8 - Wire the Module

16 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009DHn: Disable HART communications on channel n0: HART commun

Strona 9 - ATTENTION

FLEX I/O Isolated Output HART Analog Module 17Publication 1794-IN120C-EN-P - April 2009Channel Analog Fault Mode SelectionAnalog Fault Mode Decima

Strona 10 - Ground the Module

18 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009Channel Data FormatsFormat(1)Bits Format NameSignal Range U

Strona 11 - Module Wiring

FLEX I/O Isolated Output HART Analog Module 19Publication 1794-IN120C-EN-P - April 2009Cyclic HART Input DataThe HART input data holds the primary

Strona 12 - Wire Connections

2 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009Important User InformationSolid state equipment has operatio

Strona 13 - Output Map

20 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009HART Input DataWord Bit15141312111098765432100 Reserved CH7

Strona 14 - Configuration Map

FLEX I/O Isolated Output HART Analog Module 21Publication 1794-IN120C-EN-P - April 200950…61Words 2…13 for channel 462…73Words 2…13 for channel 57

Strona 15

22 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009HART Input Data descriptionsCHn: HART CMD 3 Communication S

Strona 16 - Byte Order

FLEX I/O Isolated Output HART Analog Module 23Publication 1794-IN120C-EN-P - April 2009Status IndicatorThe OK status indicator is bicolor, red, an

Strona 17 - HART Current Ratio

24 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009Absolute accuracy ± 0.1% Full Scale @ 25 °C ± 0.35% Full S

Strona 18 - Channel Data Formats

FLEX I/O Isolated Output HART Analog Module 25Publication 1794-IN120C-EN-P - April 2009North American temperature codeT4IEC Temp Code T4Dimensions

Strona 19 - Cyclic HART Input Data

26 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Sho

Strona 20 - HART Input Data

FLEX I/O Isolated Output HART Analog Module 27Publication 1794-IN120C-EN-P - April 2009CertificationsCertification (when product is marked)(1)Valu

Strona 21

Publication 1794-IN120C-EN-P - April 2009 PN-44689Supersedes Publication 1794-IN120B-EN-P - October 2008 Copyright © 2009 Rockwell Automation, Inc. A

Strona 22 - HART Input Data descriptions

FLEX I/O Isolated Output HART Analog Module 3Publication 1794-IN120C-EN-P - April 2009Environment and Enclosure ATTENTIONThis equipment is

Strona 23 - Specifications

4 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009Preventing Electrostatic Discharge ATTENTIONThis pr

Strona 24

FLEX I/O Isolated Output HART Analog Module 5Publication 1794-IN120C-EN-P - April 2009North American Hazardous Location Approval The following i

Strona 25 - Environmental

6 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 2009European Hazardous Location Approval European Zone

Strona 26

FLEX I/O Isolated Output HART Analog Module 7Publication 1794-IN120C-EN-P - April 2009Install the ModuleRead this for information about how to ins

Strona 27 - Certifications

8 FLEX I/O Isolated Output HART Analog Module Publication 1794-IN120C-EN-P - April 20093. Make sure the pins on the bottom of the module are straig

Strona 28 - Installation Assistance

FLEX I/O Isolated Output HART Analog Module 9Publication 1794-IN120C-EN-P - April 20092. Connect each channel signal return to the associated term

Komentarze do niniejszej Instrukcji

Brak uwag