Rockwell-automation 1771-DB BASIC MODULE Instrukcja Użytkownika Strona 151

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 150
Chapter
Commands
10
10 -21
Use the VER command to print the BASIC module sign-on message that
displays the current version of the firmware.
Syntax
VER
Return
Example
READY
>VER
PLC BASIC Module-Catalog Number 1771-DB/B
Firmware Revision: A
Allen-Bradley Company, Copyright 1989, 1990, 1991, 1992, 1993 1994
All rights reserved
Use the XFER command to transfer the current selected program in ROM
to RAM and select RAM mode. After the XFER command executes, you
can edit the program in the same way you edit any RAM program.
Important: The XFER command clears existing RAM programs.
Syntax
XFER
Return
Example
READY
>XFER
VER
XFER
Przeglądanie stron 150
1 2 ... 146 147 148 149 150 151 152 153 154 155 156 ... 393 394

Komentarze do niniejszej Instrukcji

Brak uwag