Rockwell-automation 1771-DB BASIC MODULE Instrukcja Użytkownika Strona 7

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 6
Preface
A
Summary of Changes
SOC-5
Call Routine Changes and Additions
These calls are new to the Series B, BASIC module:
Statement Page
CALL 0
reset the module 12 -2
CALL 14 SLC 16-bit signed integer to BASIC floating point 12 -8
CALL 15 SLC 16-bit unsigned integer to BASIC floating point 12 -9
CALL 16 enable/disable DF1 packet interrupt 12 -10
CALL 18 re-enable control C break function 12 -11
CALL 19 disable the control C break function 12 -12
CALL 24 BASIC floating point to SLC 16-bit signed integer 12 -15
CALL 25 BASIC floating point to SLC 16-bit binary 12 -16
CALL 29 read/write to PLC/SLC from module internal string 12 -18
CALL 49 read remote DH-485 SLC data file 12 -44
CALL 50 write to remote DH-485 SLC data file 12 -50
CALL 83 display DH485 port setup 13 -11
CALL 84 transfer DH-485 CIF to BASIC input buffer 13 -12
CALL 85 transfer BASIC output buffer to DH-485 CIF file 13 -13
CALL 86 check DH-485 interface remote write status 13 -14
CALL 87 check DH-485 interface file remote read status 13 -15
CALL 88 BASIC floating point to PLC-5 floating point 13 -16
CALL 89 PLC-5 floating point to BASIC floating point 13 -17
CALL 90 read remote DH-485 data file to BASIC input buffer 13 -18
CALL 91 write BASIC output buffer to remote DH-485 data file 13 -22
CALL 92 read remote DH-485 CIF to BASIC input buffer 13 -26
CALL 93 write output buffer to remote DH-485 CIF file 13 -29
CALL 94 display current PRT1 port setup 13 -32
CALL 95 get number of characters in PRT1 buffers 13 -32
CALL 96 clear PRT1 input/output buffers 13 -33
CALL 97 enable PRT2 DTR 13 -33
CALL 98 disable PRT2 DTR 13 -34
CALL 100 download/program assembly language to EEPROM 13 -35
CALL 101 upload user (E)EPROM code to host 13 -35
CALL 103 print PRT1 output buffer and pointer 13 -36
CALL 104 print PRT1 input buffer and pointer 13 -37
CALL 105 reset PRT1 to default settings 13 -37
CALL 108 enable DF1 driver communications 13 -38
CALL 112 user LED control 13 -47
CALL 113 disable DF1 driver communications 13 -47
CALL 114 transmit DF1 packet 13 -48
CALL 115 check DF1 status 13 -49
CALL 116 call user defined assembly language routine 13 -50
CALL 117 get DF1 packet length 13 -51
CALL 118 PLC/SLC unsolicited writes 13 -52
CALL 120 clear BASIC module input and output buffers 13 -57
CALL 122 read remote DF1 PLC data file 13 -58
CALL 123 write to remote DF1 PLC data file 13 -66