FlexLogix Controller System User Manual1794-L34 Firmware Revision 16User Manual

Strona 2 - Important User Information

Publication 1794-UM001G-EN-P - January 200710 Developing FlexLogix Controller SystemsThe documents address network communications:These documen

Strona 3 - Table of Contents

Publication 1794-UM001G-EN-P - January 2007100 Maintain the Battery3. Remove the old battery.4. Install a new 1756-BA1 battery.5. Attach the ba

Strona 4 - Develop Applications

101 Publication 1794-UM001G-EN-P - January 2007Appendix AFlexLogix System Status IndicatorsController LEDsThe table below describes the controller LED

Strona 5 - Table of Contents 5

Publication 1794-UM001G-EN-P - January 2007102 FlexLogix System Status IndicatorsNotes:

Strona 6 - 6 Table of Contents

103 Publication 1794-UM001G-EN-P - January 2007Appendix BFlexLogix Back-Up on DeviceNetUsing This AppendixThis chapter offers a solution to back-up yo

Strona 7 - Updated Information

Publication 1794-UM001G-EN-P - January 2007104 FlexLogix Back-Up on DeviceNetHow the Back-up WorksFigure shows an example back-up system. In t

Strona 8 - 8 Summary of Changes

Publication 1794-UM001G-EN-P - January 2007FlexLogix Back-Up on DeviceNet 105Requirements of the Back-UpThe FlexLogix Back-Up on DeviceNet solu

Strona 9 - Related Documentation

Publication 1794-UM001G-EN-P - January 2007106 FlexLogix Back-Up on DeviceNetPower-Up and System Start-upTo configure a FlexLogix Back-up syste

Strona 10

Publication 1794-UM001G-EN-P - January 2007FlexLogix Back-Up on DeviceNet 1079. Connect the other FlexLogix controller with a 1788-DNBO scanner

Strona 11 - Where to Start

Publication 1794-UM001G-EN-P - January 2007108 FlexLogix Back-Up on DeviceNetDeveloping the FlexLogix Back-Up ApplicationThe FlexLogix back-up

Strona 12

Publication 1794-UM001G-EN-P - January 2007FlexLogix Back-Up on DeviceNet 109Setting the Heartbeat ConstantYou can set the heartbeat constant w

Strona 13 - Install Hardware

11 Publication 1794-UM001G-EN-P - January 2007Chapter 1Where to StartUse This ChapterThe FlexLogix controller offers state-of-art control, communicati

Strona 14 - 14 Where to Start

Publication 1794-UM001G-EN-P - January 2007110 FlexLogix Back-Up on DeviceNetFigure shows rung 2 and the message set-up used on it. The messag

Strona 15 - Serial Port

Publication 1794-UM001G-EN-P - January 2007FlexLogix Back-Up on DeviceNet 111Figure shows rungs 3 & 4 and the message set-up used on it. T

Strona 16

Publication 1794-UM001G-EN-P - January 2007112 FlexLogix Back-Up on DeviceNetReading Back-up State RungYou can read the back-up state of the De

Strona 17

Publication 1794-UM001G-EN-P - January 2007FlexLogix Back-Up on DeviceNet 113Table describes the possible values this message may return when

Strona 18 - Configure the Serial Driver

Publication 1794-UM001G-EN-P - January 2007114 FlexLogix Back-Up on DeviceNetReading Back-up StatusYou can read the back-up status of the Devic

Strona 19 - Yes Click OK

Publication 1794-UM001G-EN-P - January 2007FlexLogix Back-Up on DeviceNet 115Using Indicators to Check StatusThe 1788-DNBO card’s status indica

Strona 20 - Select the Controller Path

Publication 1794-UM001G-EN-P - January 2007116 FlexLogix Back-Up on DeviceNet• The I/O during switchover is NOT bumpless. Since the programs an

Strona 21 - Communicate over Networks

117 Publication 1794-UM001G-EN-P - January 2007Appendix CInstruction LocatorWhere to Find an InstructionThis locator table lists the available instruc

Strona 22 - EtherNet/IP

Publication 1794-UM001G-EN-P - January 2007118 Instruction LocatorBRKBreakgeneral relay ladderBSLBit Shift Leftgeneral relay ladderBSRBit Shift

Strona 23

Publication 1794-UM001G-EN-P - January 2007Instruction Locator 119INSERTInsert Stringgeneral relay ladderstructured textINTGIntegratorprocess c

Strona 24 - For more information

Publication 1794-UM001G-EN-P - January 200712 Where to StartThe FlexLogix controller, part of the Logix family of controllers, provides a small

Strona 25 - ControlNet

Publication 1794-UM001G-EN-P - January 2007120 Instruction LocatorMDFMotion Direct Drive Offmotion relay ladderstructured textMDOMotion Direct

Strona 26 - Connections over ControlNet

Publication 1794-UM001G-EN-P - January 2007Instruction Locator 121PIDEEnhanced PIDprocess control structured textfunction blockPMULPulse Multip

Strona 27

Publication 1794-UM001G-EN-P - January 2007122 Instruction LocatorTONRTimer On Delay with Resetgeneral structured textfunction blockTOTTotalize

Strona 28 - DeviceNet

Publication 1794-UM001G-EN-P - January 2007IndexAadd-on instructions 77address data 62AOI 77architecture 11ASCII characters 37-38Bback-upFlexLogix bac

Strona 29

Publication 1794-UM001G-EN-P - January 2007124 IndexDdesign 12develop applicationdefine tasks 71-73fault handler 81for more information 74monit

Strona 30 - Define Data Blocks

Publication 1794-UM001G-EN-P - January 2007Index 125instruction locator 117isolatorconnected to the serial port 15-17Lladder diagram 76language

Strona 31 - Procedures Manual, 1756-PM001

Publication 1794-UM001G-EN-P - January 2007126 IndexTtagconsumed 46for more information 75organize 75produced 46task 69defining 71priority 71tr

Strona 32

Publication CIG-CO521C-EN-P- May 2003 PN953014-91957782-91How Are We Doing?Your comments on our technical publications will help us serve you better

Strona 33 - Communicate with DF1 devices

Other CommentsPLEASE FOLD HERENO POSTAGE NECESSARY IF MAILED IN THE UNITED STATESBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO. 18235 CLEVELAND OHPOST

Strona 35

Publication 1794-UM001G-EN-P - January 2007Where to Start 13Install HardwareTo install a FlexLogix controller, follow these steps:See:• FlexLog

Strona 36 - 1. Select ASCII protocol

Publication 1794-UM001G-EN-P - January 2007 130 PN 953014-91Supersedes Publication 1794-UM001F-EN-P - May 2005 Copyright © 2007 Rockwell Automation, I

Strona 37

Publication 1794-UM001G-EN-P - January 200714 Where to StartNotes:

Strona 38 - Modbus support

15 Publication 1794-UM001G-EN-P - January 2007Chapter 2Directly Connect to the Controller via the Serial PortUse This ChapterThis chapter describes ho

Strona 39

Publication 1794-UM001G-EN-P - January 200716 Directly Connect to the Controller via the Serial PortOne possible isolator is the 1761-NET-AIC i

Strona 40

Publication 1794-UM001G-EN-P - January 2007Directly Connect to the Controller via the Serial Port 173. Connect the appropriate cable to the ser

Strona 41

Publication 1794-UM001G-EN-P - January 200718 Directly Connect to the Controller via the Serial PortConfigure the Serial DriverUse RSLinx softw

Strona 42 - Third Party

Publication 1794-UM001G-EN-P - January 2007Directly Connect to the Controller via the Serial Port 194. Specify the serial port settings:a. From

Strona 43

Important User InformationAllen-Bradley, FlexLogix, Logix5000, RSLogix, RSLogix 5000, Rockwell Automation, RSNetWorx, and RSLinx are trademarks of Roc

Strona 44

Publication 1794-UM001G-EN-P - January 200720 Directly Connect to the Controller via the Serial PortSelect the Controller PathIn RSLogix 5000 s

Strona 45 - (Interlock) Data

21 Publication 1794-UM001G-EN-P - January 2007Chapter 3Communicate over NetworksUse This ChapterThe FlexLogix controller supports additional networks

Strona 46

Publication 1794-UM001G-EN-P - January 200722 Communicate over NetworksThis chapter summarizes the FlexLogix controller’s communications capabi

Strona 47 - Messages

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 23The EtherNet/IP communication modules:• support messaging, produced/cons

Strona 48

Publication 1794-UM001G-EN-P - January 200724 Communicate over NetworksConnections over EtherNet/IPYou indirectly determine the number of conne

Strona 49 - Connection Overview

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 25ControlNetFor ControlNet communications, install a ControlNet communicat

Strona 50 - Calculate Connection Use

Publication 1794-UM001G-EN-P - January 200726 Communicate over NetworksIn this example:• The controllers can produce and consume tags among eac

Strona 51

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 27more reliable communications between devices compared to unconnected mes

Strona 52 - Connections Example

Publication 1794-UM001G-EN-P - January 200728 Communicate over NetworksFor more information...The ControlNet Modules in Logix5000 Control Syste

Strona 53 - Select I/O Modules

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 29Use these software products when you use a FlexLogix controller on Devic

Strona 54 - Place Local I/O Modules

3 Publication 1794-UM001G-EN-P - January 2007Table of ContentsImportant User Information . . . . . . . . . . . . . . . . . . . . . . . . . . 2Summary

Strona 55 - Configure I/O

Publication 1794-UM001G-EN-P - January 200730 Communicate over NetworksDefine Data BlocksHow you configure the DeviceNet devices determines how

Strona 56

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 31SerialThe RS-232 port is a non-isolated serial port built-in to the fron

Strona 57 - I/O connections

Publication 1794-UM001G-EN-P - January 200732 Communicate over NetworksDF1 slave mode using a controller as a slave station in a master/slave s

Strona 58

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 331. Determine whether you need an isolator.For more information on determ

Strona 59 - Configure Distributed I/O

Publication 1794-UM001G-EN-P - January 200734 Communicate over NetworksTo configure the controller for DF1 communications:For more information.

Strona 60

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 35Communicate with ASCII devicesWhen configured for user mode, you can use

Strona 61

Publication 1794-UM001G-EN-P - January 200736 Communicate over NetworksTo configure the controller for ASCII communications:On this tab Do this

Strona 62 - Address I/O Data

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 37The controller supports several instructions to manipulate ASCII charact

Strona 63 - Is Updated

Publication 1794-UM001G-EN-P - January 200738 Communicate over NetworksConvert data to or from ASCII charactersFor more information...The Logix

Strona 64 - Monitor I/O Modules

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 39DH-485For DH-485 communication, use the serial port of the controller. H

Strona 65

Publication 1794-UM001G-EN-P - January 20074 Table of ContentsChapter 5Place, Configure, and Monitor I/OUse This Chapter . . . . . . . . . . .

Strona 66 - Reconfigure an I/O Module

Publication 1794-UM001G-EN-P - January 200740 Communicate over NetworksOn the DH-485 network, the FlexLogix controller can send and receive mes

Strona 67 - In this property: Select:

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 41• RSLogix 5000 programming software to configure the serial port of the

Strona 68

Publication 1794-UM001G-EN-P - January 200742 Communicate over NetworksThird PartyThe FlexLogix controller can operate on third-party networks.

Strona 69

Publication 1794-UM001G-EN-P - January 2007Communicate over Networks 43SizeThe size field determines how large the connections are between the

Strona 70 - Develop Programs

Publication 1794-UM001G-EN-P - January 200744 Communicate over NetworksNotes:

Strona 71 - Defining tasks

45 Publication 1794-UM001G-EN-P - January 2007Chapter 4Manage Controller CommunicationsUse This ChapterProduce and Consume (Interlock) DataThe control

Strona 72 - 30252015105 454035 50 6

Publication 1794-UM001G-EN-P - January 200746 Manage Controller CommunicationsFor two controllers to share produced or consumed tags, both cont

Strona 73 - Defining routines

Publication 1794-UM001G-EN-P - January 2007Manage Controller Communications 47Send and Receive MessagesMessages transfer data to other devices,

Strona 74 - Sample controller projects

Publication 1794-UM001G-EN-P - January 200748 Manage Controller CommunicationsThe controller has the following limits on the number of connecti

Strona 75 - Organize Tags

Publication 1794-UM001G-EN-P - January 2007Manage Controller Communications 49Connection OverviewA Logix5000 system uses a connection to establ

Strona 76 - Language

Publication 1794-UM001G-EN-P - January 2007Table of Contents 5Chapter 7Configure PhaseManagerUse This Chapter . . . . . . . . . . . . . . . .

Strona 77 - Add-On Instructions

Publication 1794-UM001G-EN-P - January 200750 Manage Controller CommunicationsCalculate Connection UseTo calculate the total number of local co

Strona 78

Publication 1794-UM001G-EN-P - January 2007Manage Controller Communications 51message (depending on type) 1block-transfer message 1totalRemote

Strona 79 - Monitor Controller Status

Publication 1794-UM001G-EN-P - January 200752 Manage Controller CommunicationsConnections ExampleIn this example system the FlexLogix controlle

Strona 80 - Monitor Connections

53 Publication 1794-UM001G-EN-P - January 2007Chapter 5Place, Configure, and Monitor I/OUse This ChapterSelect I/O ModulesWhen selecting 1794 FLEX I/O

Strona 81

Publication 1794-UM001G-EN-P - January 200754 Place, Configure, and Monitor I/OPlace Local I/O ModulesThe FlexLogix controller supports a local

Strona 82 - Overhead Percentage

Publication 1794-UM001G-EN-P - January 2007Place, Configure, and Monitor I/O 55The FlexLogix controller also supports distributed (remote) I/O

Strona 83

Publication 1794-UM001G-EN-P - January 200756 Place, Configure, and Monitor I/OWhen you add a module, you also define a specific configuration

Strona 84

Publication 1794-UM001G-EN-P - January 2007Place, Configure, and Monitor I/O 57I/O connectionsA Logix5000 system uses connections to transmit I

Strona 85 - Use the Event Task

Publication 1794-UM001G-EN-P - January 200758 Place, Configure, and Monitor I/OConnections for remote devicesTo optimize the number of availabl

Strona 86 - Triggering the Event Task

Publication 1794-UM001G-EN-P - January 2007Place, Configure, and Monitor I/O 59Configure Distributed I/O on EtherNet/IPTo communicate with dist

Strona 87

Publication 1794-UM001G-EN-P - January 20076 Table of Contents

Strona 88

Publication 1794-UM001G-EN-P - January 200760 Place, Configure, and Monitor I/OConfigure Distributed I/O on ControlNetTo communicate with distr

Strona 89 - Configure PhaseManager

Publication 1794-UM001G-EN-P - January 2007Place, Configure, and Monitor I/O 61Configure Distributed I/O on DeviceNetTo communicate with the I/

Strona 90

Publication 1794-UM001G-EN-P - January 200762 Place, Configure, and Monitor I/OAddress I/O DataI/O information is presented as a set of tags.•

Strona 91 - State Model Overview

Publication 1794-UM001G-EN-P - January 2007Place, Configure, and Monitor I/O 63Determine When Data Is UpdatedFlexLogix controllers update date

Strona 92 - How equipment changes states

Publication 1794-UM001G-EN-P - January 200764 Place, Configure, and Monitor I/OMonitor I/O ModulesThe FlexLogix controller offers different lev

Strona 93

Publication 1794-UM001G-EN-P - January 2007Place, Configure, and Monitor I/O 65Monitor a rack-optimized connectionThe controller views the DIN

Strona 94 - Requirements

Publication 1794-UM001G-EN-P - January 200766 Place, Configure, and Monitor I/OReconfigure an I/O ModuleIf an I/O module support reconfiguratio

Strona 95 - Instructions

Publication 1794-UM001G-EN-P - January 2007Place, Configure, and Monitor I/O 67Reconfigure a module via a MSG instructionTo change the configur

Strona 96

Publication 1794-UM001G-EN-P - January 200768 Place, Configure, and Monitor I/ONotes:

Strona 97 - Maintain the Battery

69 Publication 1794-UM001G-EN-P - January 2007Chapter 6Develop ApplicationsUse This ChapterManage TasksA Logix5000 controller lets you use multiple ta

Strona 98 - Estimating Battery Life

7 Publication 1794-UM001G-EN-P - January 2007Summary of ChangesIntroductionThis release of this document contains new and updated information. To find

Strona 99 - Replacing a Battery

Publication 1794-UM001G-EN-P - January 200770 Develop ApplicationsDevelop ProgramsThe controller operating system is a preemptive multitasking

Strona 100 - ATTENTION

Publication 1794-UM001G-EN-P - January 2007Develop Applications 71Defining tasksA task provides scheduling and priority information for a set o

Strona 101 - Controller LEDs

Publication 1794-UM001G-EN-P - January 200772 Develop ApplicationsHowever, if you schedule two high priority tasks (1 to 5) to run every millis

Strona 102

Publication 1794-UM001G-EN-P - January 2007Develop Applications 73Notes:A. The highest priority task interrupts all lower priority tasks.B. The

Strona 103 - Using This Appendix

Publication 1794-UM001G-EN-P - January 200774 Develop ApplicationsSample controller projectsRSLogix 5000 Enterprise programming software includ

Strona 104 - How the Back-up Works

Publication 1794-UM001G-EN-P - January 2007Develop Applications 75Organize TagsWith a Logix5000 controller, you use a tag (alphanumeric name) t

Strona 105 - Requirements of the Back-Up

Publication 1794-UM001G-EN-P - January 200776 Develop ApplicationsSelect a Programming LanguageThe FlexLogix controller supports these programm

Strona 106 - System Start-up

Publication 1794-UM001G-EN-P - January 2007Develop Applications 77Add-On InstructionsWith version 16 of RSLogix 5000 programming software, you

Strona 107

Publication 1794-UM001G-EN-P - January 200778 Develop Applicationsunique name so that you don’t accidentally overwrite another instruction of t

Strona 108 - Back-Up Application

Publication 1794-UM001G-EN-P - January 2007Develop Applications 79Monitor Controller StatusThe FlexLogix controller uses Get System Value (GSV)

Strona 109

Publication 1794-UM001G-EN-P - January 20078 Summary of ChangesNotes:

Strona 110

Publication 1794-UM001G-EN-P - January 200780 Develop ApplicationsMonitor ConnectionsIf communication with a device in the I/O configuration of

Strona 111

Publication 1794-UM001G-EN-P - January 2007Develop Applications 81• If Module_Status is any value other than 4, the controller is not communica

Strona 112 - Reading Back-up State Rung

Publication 1794-UM001G-EN-P - January 200782 Develop Applications4. Develop a routine for the Controller Fault Handler. See the Logix5000 Cont

Strona 113

Publication 1794-UM001G-EN-P - January 2007Develop Applications 83the system overhead percentage does increase communications performance, it a

Strona 114 - Reading Back-up Status

Publication 1794-UM001G-EN-P - January 200784 Develop ApplicationsIf you use the default time slice of 20%, the system overhead interrupts the

Strona 115 - Debugging Tips

Publication 1794-UM001G-EN-P - January 2007Develop Applications 85Use the Event TaskThe event task is available with FlexLogix controllers usin

Strona 116

Publication 1794-UM001G-EN-P - January 200786 Develop ApplicationsTriggering the Event TaskTo trigger an event task based on conditions in your

Strona 117 - Instruction Locator

Publication 1794-UM001G-EN-P - January 2007Develop Applications 87Programmatically Determine if an EVENT Instruction Triggered aTaskTo determin

Strona 118

Publication 1794-UM001G-EN-P - January 200788 Develop ApplicationsNotes:

Strona 119

89 Publication 1794-UM001G-EN-P - January 2007Chapter 7Configure PhaseManagerUse This ChapterThe PhaseManager option of RSLogix 5000 software gives yo

Strona 120

9 Publication 1794-UM001G-EN-P - January 2007PrefaceDeveloping FlexLogix Controller SystemsIntroductionUse this manual to become familiar with the Fle

Strona 121

Publication 1794-UM001G-EN-P - January 200790 Configure PhaseManagerHere’s how the PhaseManager into RSLogix 5000 programming software:MainTask

Strona 122

Publication 1794-UM001G-EN-P - January 2007Configure PhaseManager 91State Model OverviewA state model divides the operating cycle of your equip

Strona 123

Publication 1794-UM001G-EN-P - January 200792 Configure PhaseManagerWith a state model, you define the behavior of your equipment and put it in

Strona 124 - 124 Index

Publication 1794-UM001G-EN-P - January 2007Configure PhaseManager 93PhaseManager uses the following transitions:HoldingHoldIdleStartRunningHold

Strona 125 - Index 125

Publication 1794-UM001G-EN-P - January 200794 Configure PhaseManagerManually change statesRSLogix 5000 software has a window that lets you moni

Strona 126 - 126 Index

Publication 1794-UM001G-EN-P - January 2007Configure PhaseManager 95Equipment Phase InstructionsThe controller supports several instructions to

Strona 127 - How Are We Doing?

Publication 1794-UM001G-EN-P - January 200796 Configure PhaseManagerNotes:

Strona 128 - BUSINESS REPLY MAIL

97 Publication 1794-UM001G-EN-P - January 2007Chapter 8Maintain the BatteryUsing this AppendixStoring Replacement BatteriesBecause a battery may leak

Strona 129

Publication 1794-UM001G-EN-P - January 200798 Maintain the BatteryEstimating Battery LifeWhen the battery is about 95 percent discharged, the c

Strona 130 - Rockwell Automation

Publication 1794-UM001G-EN-P - January 2007Maintain the Battery 99Use the off-time percentage you calculated with the following table to determ