20 FLEX I/O Isolated Output HART Analog Module
Publication
1794-IN120C-EN-P - April 2009
HART Input Data
Word Bit
1514131211109876543210
0 Reserved C
H
7
C
H
6
C
H
5
C
H
4
C
H
3
C
H
2
C
H
1
C
H
0
(HART CMD 3 Communications Status)
1 Reserved
2 CH0 HART Field Device Status CH0 HART Comm Status
3 Reserved F
V
A
T
V
A
S
V
A
P
V
A
CH0 HART Loop Status
4 CH0 HART Primary Value (IEEE 754-1985 Single-Precision 32 bit floating point)
5
6 CH0 HART Secondary Value (IEEE 754-1985 Single-Precision 32 bit floating point)
7
8 CH0 HART Tertiary Value (IEEE 754-1985 Single-Precision 32 bit floating point
9
10 CH0 HART Fourth (Quaternary) Value (IEEE 754-1985 Single-Precision 32 bit
floating point)
11
12 CH0 SV Units Code CH0 PV Units Code
13 CH0 FV Units Code CH0 TV Units Code
14…
25
Words 2…13 for channel 1
26…
37
Words 2…13 for channel 2
38…
49
Words 2…13 for channel 3