16 Kinetix 3 Component Servo Drives
Publication 2071-IN001E-EN-P - August 2014
Kinetix 3 Drive Power and Ground Wiring
This installation applies to a TL-Series (Bulletin TL) motor with 2090-DANPT-16Sxx cable.
Terminate the input-power ground wire with a ring lug. Attach input power and motor power
grounds to ground screws, and torque to 1.25 N•m (11 lb•in).
Item Description
1 2071-AP4 Kinetix 3 drive shown
2 Input power cable
3 Control power cable
4 Motor power cable
5Ring lug
6 Ground screw
(1)
(1) 2071-AP0, 2071-AP1, and 2071-AP2 drives have one grounding screw on the heatsink.
2071-AP4, 2071-AP8, 2071-A10, and 2071-A15 drives have two ground screws on the heatsink.
2
4
5
6
1
3