11. If you are reusing the bimetal thermostat mounted on the left SCR module
leg assembly, disconnect the wires from the connector mounted on the
middle, left-side of the assembly.
12. Remove the two hexalobular screws that secure the thermostat to the heat
sink and remove the thermostat.
Step 4: Install the New
SCR Module Leg
Assemblies
Install the new SCR module leg assemblies in the reverse order of removal as
detailed in Step 3: Remove the Existing SCR Module Leg Assemblies
on
page 4.
Important:Apply thermal grease to the bottom of the bimetal thermostat
before installation.
Tightening torque for the bimetal thermostat is 1.0 N•m (8.9 lb•in).
Tightening torque for the SCR module leg assemblies is 4.5…5.0 N•m
(40.0…44.4 lb•in).
Tightening torque for the SCR module input and output terminals to the
fuse terminals and DC output bus bars is 45 N•m (398 lb•in).