PLC-5 Data Pass–ThroughD–4
Publication 2706-6.2
You can send only one file at a time to a DL40 Plus. Select the
Transfer menu and highlight Download to DL40 (Remote I/O)
function; press [ ]. The Download (Over Remote I/O) window
opens. Select Message File to download and Communication File to
use.
Highlight Download <filename> press [ ]. Answer Yes when
asked if you want to Start Downloading Now?
Note: When downloading through Remote I/O, Download Type is
automatically set to All. You can’t just transfer Parameters.
You can send only one file at a time from a DL40. Highlight Upload
from DL40 (Remote I/O) function; press [ ]. The Upload (Over
DH+ and Remote I/O) window opens. Select Message File to upload
and Communication File to use.
Highlight Upload <filename> press [ ]. Answer Yes when asked if
you want to Start Uploading Now?
Downloading Files
Uploading Files