Process Configuration and Operation Software for Windowst
2
Publication
672310.1  August 1996
Hardware Requirements
PCO supports any combination of hardware from this list.
Requirement: Options:
Computer IBM PC Compatible 386/486/586 (Pentium), with at least 8 mb RAM and 14 mb Hard Drive space available.
Note: If you are running the PCO software tools and an MMI on this system, we highly recommend that you use at least 16
mb RAM.
PLC Processors
PLC5/30 series A and later
PLC5/40 series B and later
PLC5/60 series B and later
PLC5/80 series C and later
I/O Module(s) 1771NBRC Highresolution Isolated Analog
(RTD Input; 420mA Output)
1771CFM Configurable Flowmeter
1771NBTC Highresolution Isolated Analog
(TC/mV Input; 420mA Output)
1771IFE Analog Input
1771NBVC Highresolution Isolated Analog
(+
5V Input; 420mA Output)
1771IL Isolated Analog Input
1771NIS Highresolution Isolated Analog (420mA Input) 1771IR RTD Input
1771NIV Highresolution Isolated Analog (+5V Input) 1771IXE Thermocouple
1771NIVR Highresolution Isolated Analog (+5V Input) 1771IXHR Highresolution Thermocouple
1771NIVT Highresolution Isolated Analog
(+
5V Input; TC/mV Input)
1771QRD Pulse
1771NOC Highresolution Isolated Analog (420mA Output) 1771OFE Analog Output
1771NOV Highresolution Isolated Analog (+10V Output) 1771NR Highresolution Isolated Analog (RTD Input)
1771NT1 Highresolution Isolated Analog (TC/mV Input)
PanelView Terminal
(optional)
2711 Series (keypad version only)
Note: PLC-5/11 and -5/20 processors may also be used under some
circumstances. While use of these processors for PCO is somewhat
limited by memory considerations, their use may still be feasible,
depending on your applications and the number of PCO functions
you need. Use the sizing spreadsheet to determine if you will be able
to run your applications with these processors.
Note: There are many other build-to-order N-Series modules that
may be compatible with this software that are not listed here. Check
with your Allen-Bradley representative to determine compatibility.
Software Requirements
You need this software to run PCO.
Requirement: Options:
operating system
Windowst 3.x or Windowst 95
operator interface
FactoryLinkt, FIXt, or RSViewt MMI system
1
application software
Microsoft Excelt 5.0 or Microsoft Excelt for Windows 95
pp
INTERCHANGEt 6.1.0 or later (cat. no. 9351WKTSR)
PanelBuildert Software (cat. nos. 2711KA1, KC1, ND1, TA1,
and TC1) if you plan to use PanelView screens
PLC5 Programming Software
1
(6200 Series, AI, or WinLogic))
1
Contact
your local AllenBradley representative for a list of other compatible operator interface and PLC
processor programming software packages.