Rockwell-automation GMLC Reference Manual Instrukcja Użytkownika Strona 129

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 958
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 128
Publication GMLC-5.2 - November 1999
92 Configuring Axis Use
Motion continues.
The controller indicates a fault status.
To configure the Fault Action page, make one of the above three entries in
the following fields:
Hard Overtravel
Select the action that occurs when servo axis travel touches a travel limit
switch, thereby causing a Hardware_overtravel_fault.
Note: Enable the use of travel limit switches in the Overtravel page of
this dialog box.
Soft Overtravel
Select the action that occurs when servo axis travel reaches a software
travel limit, thereby causing a Software_overtravel_fault.
Note: Enable the use of software travel limits in the Overtravel page of
this dialog box.
Position Error
Select the action that occurs in response to a servo axis
Position_error_fault .
Note: A position error fault occurs when the difference between
Command Position and Actual Position exceeds the Error
Tolerance set in the Dynamics page of this dialog box.
!
ATTENTION: Selecting the wrong fault action for
your application can cause a dangerous condition. Keep
clear of moving machinery.
Przeglądanie stron 128
1 2 ... 124 125 126 127 128 129 130 131 132 133 134 ... 957 958

Komentarze do niniejszej Instrukcji

Brak uwag