Chapter 2 Add a PowerFlex 525 Drive to a Controller Project
The Module Properties dialog box for the drive appears.
6. Type a Name for the drive.
7. Type the same IP address for the drive as
the IP address you assigned to the
EtherNet/IP adapter in Configure the
Embedded EtherNet/IP Adapter on
page 16.
8. Click Change.
The Module Definition dialog box appears.
9. In the Module Definition dialog box,
complete the following tasks.
a. From the Drive Rating pull-down
menu, choose the rating for your
PowerFlex 525 drive.
b. From the Electronic Keying pull-
down menu, choose Disable Keying.
c. Click OK.
A message box appears to indicate that the module data types and properties will be changed due to these
selections.
10. Click Yes.